OUTLINE
A single zone automatic air conditioning system, dual zone automatic air conditioning system (left and right independent control) or manual air conditioning system is available depending on the model.
Depending on models, an inside-and-outside dual air layer type air conditioning unit is used.
HFC-134a or HFO-1234yf refrigerant is used depending on the models.
SPECIFICATION
Ventilation and Heater Core
|
*1: Models with automatic air conditioning system *2: Models with manual air conditioning system *3: Models with dual air layer type *4: Models with single air layer type |
|||
| Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum (SFA) - II | |
| Size (W x H x L) | mm (in.) | 180.7 x 120 x 27
(7.1 x 4.7 x 1.1) |
|
| Blower with Fan Motor Sub-assembly | Motor Type | DC Ferrite Brushless*1
DC*2 |
|
| Fan Type | Semi Sirocco | ||
| Fan Size (Dia. x H)*3 | mm (in.) | Upper Side: 122.0 x 55.0 (4.8 x 2.2)
Lower Side: 125.0 x 38.0 (4.9 x 1.5) |
|
| Fan Size (Dia. x H)*4 | mm (in.) | 137.0 x 70 (5.4 x 2.8) | |
Air Conditioning
|
*1: Gasoline models *2: HV models *3: Models using HFC-134a (R134a) refrigerant *4: Models using HFO-1234yf (R1234yf) refrigerant *5: Model with stop and start system *6: Model without stop and start system |
|||
| Cooler Condenser Assembly | Type | Global Inner-fin Condenser (GIC) | |
| Size (W x H x L) | mm (in.) | 530 x 376.2 x 11.5 (20.9 x 14.8 x 0.5)*1
630 x 376.2 x 11.5 (24.8 x 14.8 x 0.5)*2 |
|
| Fin Pitch | mm (in.) | 2.5 (0.10) | |
| Cooler Compressor Assembly*1 | 5TSE10 | ||
| Compressor with Motor Assembly*2 | ESB20C | ||
| Refrigerant | Type | HFC-134a (R-134a)*3, HFO-1234yf (R-1234yf)*4 | |
| Evaporator | Type | Cold Storage (CS)*5
Beneficial Refrigerant Stream (BRS) Evaporator*6 |
|
| Size (W x H x L) | mm (in.) | 199.3 x 231.0 x 38.0 (7.8 x 9.1 x 1.5) | |
| Fin Pitch | mm (in.) | 3.0 (0.12) | |
MAIN FEATURES
The air conditioning system has the following features:
|
*1: Models with automatic air conditioning system *2: Models with manual air conditioning system *3: Gasoline models *4: Gasoline models with stop and start system |
|
| High Performance | ·
A high efficiency type clean air filter, which has a pollen removal effect, is used. Depending on models, an odor removal effect has been used on the clean air filter. ·
The blower control has 7 levels in manual mode and 31 levels in auto mode for more precise control.*1 ·
The blower control has 4 levels.*2 ·
Neural network control is used so passengers can finely control the air conditioning for maximum comfort.*1 ·
Using the following features of the compressor (continuously variable capacity compressor), high cooling performance and a quiet cabin have been achieved:*3 -
Oil Separator -
Variable Suction Side Throttle -
Solenoid Valve with Built-in Crank Chamber to Suction Passage (CS) Valve ·
The rear outlet is installed under the driver's seat and under the passenger seat to ensure a comfortable rear passenger cooling performance. |
| Lightweight | ·
An air conditioning harness assembly with a built-in communication/driver IC is used in a lightweight wire harness design to allow a reduced number of wires. ·
The use of this type of connector means that pulse pattern type servo motors can be used. |
| Compact | A blower motor with a built-in blower motor controller is used to achieve a compact construction.*1 |
| Others | The following parts are used to ensure high cooling performance while realizing a compact and lightweight construction.
·
Semi-center Location Air Conditioning Unit ·
Straight Flow Aluminum (SFA)-II Heater Radiator Sub-assembly ·
Global Inner-fin Condenser (GIC) Sub-cool Condenser ·
Beneficial Refrigerant Stream (BRS) Evaporator ·
Cold Storage Evaporator*4 |
PRECAUTION
Precaution for Refrigerant HFO-1234yf
Always use HFO-1234yf as the refrigerant.
Do not charge the system with refrigerant near open flames, as HFO-1234yf is combustible.
When charging the system with refrigerant, make sure the area is well ventilated (especially be careful in areas where the gas can easily accumulate such as under lifts and in garage pits, as the gas is heavier than air).
Follow any local regulations regarding combustible gases.
Be sure to use a refrigerant recovery unit that is compatible with HFO-1234yf systems.
The shape of the service port for refrigerant charging has an exclusive design conforming to international standards for HFO-1234yf to prevent improper refrigerant charging.