Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2020.09
NM36W0E _58 Vehicle Interior _088377 HEATING / AIR CONDITIONING _0421295 AIR CONDITIONING SYSTEM DE DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DETAILS  COOLER CONDENSER  


CONSTRUCTION


a.

Models with GIC Type

i.

A Global Inner-fin Condenser (GIC) is provided. This condenser has tubes with high-density inner fins, and outer fins which allow the use of thinner cores, contributing to the efficiency of cooling performance.

Y258931C01
5.25,0.844 5.5,0.5 5.5,0.5 5.667,0.5 true 4.5,3.156 4.667,3.156 4.667,3.156 4.917,2.813 true 6.083,2.021 6.208,2.188 6.208,2.188 6.375,2.188 true 5.74,0.406 6.052,0.563 0.313,0.156 10 false *1 6.448,2.094 6.76,2.25 0.313,0.156 10 false *2 4.281,3.073 4.594,3.229 0.313,0.156 10 false *3 4.365,2.552 4.677,2.708 0.313,0.156 10 false *a 4.365,1.25 4.521,1.448 0.156,0.198 10 false A 5.677,1.25 5.833,1.448 0.156,0.198 10 false A 0.083,3.51 0.396,3.667 0.313,0.156 10 false *b
*1 Tube (Inner Fin) *2 Outer Fin
*3 Fin Louver - -
*a A - A Cross Section *b The illustration shown is an example only.



ii.

The cooler condenser assembly consists of 2 cooling portions: a condensing portion and a super-cooling portion. These portions are integrated with a gas-liquid separator (modulator). This cooler condenser assembly uses a sub-cool cycle that offers excellent heat-exchange performance.


iii.

In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied state.

Y259103C01
3.5,1 3.25,0.5 3.25,0.5 3.083,0.5 true 2.5,3.333 2.667,3.333 2.667,3.333 2.917,2.833 true 5.448,1.583 5.865,1.083 5.865,1.083 6.031,1.083 true 1.115,1.688 1.427,1.844 0.313,0.156 10 false *a 1.125,2.688 1.438,2.844 0.313,0.156 10 false *b 2.865,0.417 3.177,0.573 0.313,0.156 10 false *c 6.104,1.01 6.417,1.167 0.313,0.156 10 false *d 2.281,3.25 2.594,3.406 0.313,0.156 10 false *e 0.219,3.552 0.531,3.708 0.313,0.156 10 false *f
*a Gaseous Refrigerant *b Liquid Refrigerant
*c Condensing Portion *d Modulator
*e Super-cooling Portion *f The illustration shown is an example only.


HINT:
·

The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system were recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system will be affected. If the system is overcharged with refrigerant, this will also lead to reduced performance.

·

For the proper method of verifying the amount of the refrigerant and to recharge the system with refrigerant, refer to the Repair Manual.





b.

Models with MF-IV Type

i.

The cooler condenser assembly consists of 2 cooling portions: a condensing portion and a supercooling portion. These portions are integrated with a gas-liquid separator (modulator). This cooler condenser assembly uses a sub-cool cycle that offers excellent heat-exchange performance.


ii.

In the sub-cool cycle, after the refrigerant passes through the condensing portion of the condenser, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the evaporator in an almost completely liquefied state.

Y267268C01
3.167,1.167 3.333,1.167 3.333,1.167 3.583,1.583 true 2.667,3.708 2.833,3.708 2.833,3.708 3.083,3.292 true 6.083,2.25 6.438,1.667 6.438,1.667 6.604,1.667 true 0.385,2.438 0.698,2.594 0.313,0.156 10 false *a 0.385,3.146 0.698,3.302 0.313,0.156 10 false *b 2.958,1.052 3.271,1.208 0.313,0.156 10 false *c 6.677,1.563 6.99,1.719 0.313,0.156 10 false *d 2.458,3.604 2.771,3.76 0.313,0.156 10 false *e 0.198,4.521 0.51,4.677 0.313,0.156 10 false *f
*a Gaseous Refrigerant *b Liquid Refrigerant
*c Condensing Portion *d Modulator
*e Super-cooling Portion *f The illustration shown is an example only.


HINT:
·

The point at which the air bubbles disappear in the refrigerant of the sub-cool cycle is lower than the proper amount of refrigerant with which the system must be filled. Therefore, if the system were recharged with refrigerant based on the point at which the air bubbles disappear, the amount of refrigerant would be insufficient. As a result, the cooling performance of the system will be affected. If the system is overcharged with refrigerant, this will also lead to reduced performance.

·

For the proper method of verifying the amount of the refrigerant and to recharge the system with refrigerant, refer to the Repair Manual.