The cause of the malfunction may be a shutdown signal.
Check whether there is a shutdown signal +B short circuit.
| Area | Inspection |
|---|---|
| HSDN terminal | Check that the HSDN terminal voltage decreases to check for an open or short circuit while READY off (IG ON). |
| Hybrid vehicle control ECU, inverter, wire harness | Check for open or short circuit in hybrid vehicle control ECU, inverter and wire harness. |
Power supply to the motor is cut off due to a shutdown signal sent from the hybrid vehicle control ECU to the motor generator control ECU (MG ECU).
This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs.
If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A68-9 (HSDN) - H44-15 (E1) | Ignition switch ON | Below 4.5 V |
Post-procedure1
Turn the ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 inverter with converter assembly connector.
Disconnect the A68 and H44 hybrid vehicle control ECU connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
*b | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-22 (HSDN) or A68-9 (HSDN) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the hybrid vehicle control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for 2 minutes or more.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-22 (HSDN) - A56-6 (+B) | Ignition switch off | 10 kΩ or higher |
| A56-22 (HSDN) - A56-5 (+B2) | Ignition switch off | 10 kΩ or higher |
| A68-9 (HSDN) - H44-7 (+B1) | Ignition switch off | 10 kΩ or higher |
| A68-6 (HSDN) - H44-47 (MREL) | Ignition switch off | 10 kΩ or higher |
Post-procedure1
Reconnect the A68 and H44 hybrid vehicle control ECU connector.
Reconnect the A56 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 inverter with converter assembly connector.
Procedure1
| *a | Component without harness connected
(Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-22 (HSDN) - A56-6 (+B) | Ignition switch off | 10 kΩ or higher |
| A56-22 (HSDN) - A56-5 (+B2) | Ignition switch off | 10 kΩ or higher |
Post-procedure1
Reconnect the A56 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK