FREEZE FRAME DATA
The hybrid vehicle control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred.
Select a DTC in order to display its freeze frame data.
Check the freeze frame information recorded with the DTC.
| Tester Display | Measurement Item | Range |
|---|---|---|
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
| Target Engine Power | Target engine power | Min.: 0 W, Max.: 655350 W |
| Execute Engine Power | Execute engine power | Min.: 0 W, Max.: 655350 W |
| Target Engine Revolution | Target engine revolution | - |
| Engine Speed | Engine speed | - |
| Calculate Load | Calculate load | Min.: 0.00%, Max.: 100.00% |
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Starter Switch Signal | Starter ON / OFF signal | ON or OFF |
| Engine Idling Request | Engine idling request | ON or OFF |
| Engine Start Request (A/C) | Engine idling request from air conditioning amplifier assembly | ON or OFF |
| Engine Start Request (Engine Warm-up) | Engine idling request to warm up engine | ON or OFF |
| Engine Start Request (Hybrid/EV Battery Charging) | Engine idling request to charge HV battery | ON or OFF |
| Engine Mode | Engine status | Stop / Stop Process / Startup Process / Running |
| Engine Run Time | Elapsed time after starting engine | Min.: 0 sec, Max.: 65535 sec |
| Engine Stop Request | Engine stop request | ON or OFF |
| Engine Stop F/C Status | Engine fuel cut status | ON or OFF |
| Lack of Fuel | Lack of fuel | ON or OFF |
| Accelerator Position | Accelerator pedal depressed angle | Min.: 0.0%, Max.: 100.0% |
| Accelerator Pedal Status | Accelerator pedal status | ON or OFF |
| Accelerator Position Sensor No.1 Voltage % | Accelerator pedal position sensor No. 1 | Min.: 0.00%, Max.: 100.00% |
| Accelerator Position Sensor No.2 Voltage % | Accelerator pedal position sensor No. 2 | Min.: 0.00%, Max.: 100.00% |
| Throttle Position Sensor No.1 Voltage % | Throttle valve angle | Min.: 0.00%, Max.: 100.00% |
| Master Cylinder Control Torque | Braking torque equivalent to master cylinder brake fluid pressure
(Total braking torque) |
- |
| Brake Cancel Switch | Brake pedal status | ON or OFF |
| Shift Position | Current shift state | P / R / N / D / B |
| Shift Position (Meter) | Shift position of meter display | Not Displayed / P / R / N / D / B |
| Shift Switch Status (N,P Position) | Shift position status (N or P position) | ON or OFF |
| Shift Position Sensor (PNB) | Shift lever position sensor | ON or OFF |
| Shift Position Sensor (PR) | Shift lever position sensor | ON or OFF |
| Shift Position Sensor (DB1) | Shift lever position sensor | ON or OFF |
| Shift Position Sensor (DB2) | Shift lever position sensor | ON or OFF |
| Shift Position Sensor (N) | Shift lever position sensor | ON or OFF |
| Shift Position Sensor (R) | Shift lever position sensor | ON or OFF |
| Shift Position Sensor (P) | Shift lever position sensor | ON or OFF |
| Shift Lock Release Request | Shift lock release request | ON or OFF |
| Transaxle Oil Temperature | Hybrid vehicle transaxle oil temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Transaxle Oil Temperature Sensor Voltage | Hybrid vehicle transaxle oil temperature sensor voltage | Min: 0.00 V, Max: 4.99 V |
| FR Wheel Speed | Front wheel speed RH | Min.: 0.00 km/h, Max.: 327.67 km/h |
| FL Wheel Speed | Front wheel speed LH | Min.: 0.00 km/h, Max.: 327.67 km/h |
| RR Wheel Speed | Rear wheel speed RH | Min.: 0.00 km/h, Max.: 327.67 km/h |
| RL Wheel Speed | Rear wheel speed LH | Min.: 0.00 km/h, Max.: 327.67 km/h |
| Atmospheric Pressure | Atmospheric pressure | Min.: 0 kPa, Max.: 255 kPa |
| Intake Manifold Absolute Pressure | Intake manifold pressure of engine | Min.: 0.00 kPa, Max.: 255.00 kPa |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Intake Air Temperature | Engine intake air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| BATT Voltage | Auxiliary battery voltage
(Battery ECU assembly power source voltage) |
Min.: 0.00 V, Max.: 16.00 V |
| Smoothed Value of BATT Voltage | Smoothed value of auxiliary battery voltage | Min.: 0.000 V, Max.: 16.000 V |
| Warmup Cycle Cleared DTC | The number of times the engine is warmed up after clearing DTCs | Min.: 0, Max.: 255 |
| Distance from DTC Cleared | Drive distance after clearing DTCs | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
| Time after DTC Cleared | Elapsed time after clearing DTCs | Min.: 0 min, Max.: 65535 min |
| Running Time from MIL ON | Running time from MIL on | Min.: 0 min, Max.: 65535 min |
| Total Distance Traveled | Drive total distance | Min.: 0, Max.: 16777215 |
| Total Distance Traveled - Unit | Drive total distance unit | km or mile |
| MIL ON Run Distance | Drive distance from MIL on | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
| IGB Signal Status | IGB signal status | ON or OFF |
| IG2 Signal Status | IGP signal status | ON or OFF |
| Ready Signal | Ready signal status | ON or OFF |
| IGR | IGR terminal state | ON or OFF |
| HV/EV Activate Condition | Hybrid vehicle control system power source mode status | Normal / Remote Air Control System / Remote |
| MG Activate Condition | Motor generator control system status | ON or OFF |
| DSS Control Status | Control status of DSS (Driving Support System) | Not Control / Available / Unavailable / Disable |
| Generate Torque (Request from DSS) | Generated drive torque requested from DSS (Driving Support System) | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Primary Driving Force Adjustment Result | Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation | Accelerator / DSS |
| SMRG Status | Operating state of SMRG
(primary circuit monitor) |
ON or OFF |
| SMRG Control Status | Commanded state of SMRG | ON or OFF |
| SMRB Status | Operating state of SMRB
(primary circuit monitor) |
ON or OFF |
| SMRB Control Status | Commanded state of SMRB | ON or OFF |
| SMRP Status | Operating state of SMRP
(primary circuit monitor) |
ON or OFF |
| SMRP Control Status | Commanded state of SMRP | ON or OFF |
| Voltage Deviation between before Boosting and after Boosting during SMR Precharge | Difference in voltage before boosting and after boosting during system main relay precharge | Min.: -3276.8 V, Max.: 3276.7 V |
| A/C Consumption Power | A/C consumption power | Min.: 0.00 kW, Max.: 12.75 kW |
| Electric Component Actuation Restriction Count | Electric component actuation restriction count | 0 or 255 |
| Powertrain Drive Mode Switch | Powertrain drive mode switch staus | ON or OFF |
| EV Mode | EV mode transition availability | ON or OFF |
| EV Mode Switch | EV mode switch condition | ON or OFF |
| Inter Lock Switch | Interlock switch condition | ON or OFF |
| Inter Lock Switch (MG) | Interlock switch condition | ON or OFF |
| Stop Light Switch | Stop light switch assembly condition | ON or OFF |
| Back Up Light Relay | Back up light switch condition | ON or OFF |
| VSC/TRC OFF Switch | VSC condition | OFF / TRC OFF Mode / TRC/VSC OFF Mode |
| Airbag Status (Collision) | Airbag sensor assembly collision detection | ON or OFF |
| Airbag Status (Collision) (CAN) | Airbag sensor assembly collision detection (CAN) | Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side |
| Airbag Status (Normal) | Control state of airbag sensor assembly | ON or OFF |
| Crank Position | Crankshaft position | Min.: -128 deg (CA), Max.: 127 deg (CA) |
| TC Terminal | TC terminal state | ON or OFF |
| Generator Revolution | Generator (MG1) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm |
| Target Generator Torque | Generator (MG1) torque request value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Generator Torque | Generator (MG1) torque execution value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Revolution | Motor (MG2) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm |
| Target Motor Torque | Motor (MG2) torque request value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Torque | Motor (MG2) torque execution value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Request Motor Regenerative Brake Torque | Requested motor (MG2) regenerative braking torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Regenerate Brake Execution Torque | Motor (MG2) regenerative braking execution torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Generator Temperature | Generator (MG1) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Temperature Sensor Voltage | Generator (MG1) temperature sensor voltage | Min.: 0.00 V, Max.: 4.99 V |
| Generator Temperature just after IG ON | Generator (MG1) temperature soon after ignition switch to ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Maximum Temperature | Maximum generator (MG1) temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Temperature | Motor (MG2) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Temperature Sensor Voltage | Motor (MG2) temperature sensor voltage | Min.: 0.00 V, Max.: 4.99 V |
| Motor Temperature just after IG ON | Motor (MG2) temperature soon after ignition switch to ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Maximum Temperature | Maximum motor (MG2) temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Inverter Temperature | Generator inverter temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Inverter Temperature just after IG ON | Generator inverter temperature just after IG ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Generator Inverter Maximum Temperature | Generator inverter maximum temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Inverter Temperature | Motor inverter temperature | Min.: 8 °C (46 °F), Max.: 150 °C (302 °F) |
| Motor Inverter Temperature just after IG ON | Motor inverter temperature soon after ignition switch ON | Min.: 8 °C (46 °F), Max.: 150 °C (302 °F) |
| Motor Inverter Maximum Temperature | Maximum motor inverter temperature after ignition switch turned to ON in current trip | Min.: 8 °C (46 °F), Max.: 150 °C (302 °F) |
| Boosting Converter Temperature (Upper) | Boost converter temperature (upper) | Min.: 8 °C (46 °F), Max.: 150 °C (302 °F) |
| Boosting Converter Temperature (Lower) | Boost converter temperature (lower) | Min.: 8 °C (46 °F), Max.: 150 °C (302 °F) |
| Boosting Converter Temperature just after IG ON | Boost converter temperature soon after ignition switch to ON | Min.: 8 °C (46 °F), Max.: 150 °C (302 °F) |
| Boosting Converter Maximum Temperature | Maximum converter temperature after ignition switch turned to ON in current trip | Min.: 8 °C (46 °F), Max.: 150 °C (302 °F) |
| Generator Inverter Operation Request | Generator inverter operation request | Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement |
| Generator Inverter Fail | Generator inverter stopped | ON or OFF |
| Generator Inverter Shutdown Status | Generator inverter shutdown status | Awake or Shutdown |
| Motor Inverter Operation Request | Motor inverter operation request | Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement |
| Motor Inverter Fail | Motor inverter stopped | ON or OFF |
| Motor Inverter Shutdown Status | Motor inverter shutdown status | Awake or Shutdown |
| Boosting Converter Operation Request | Boosting converter operation request | Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering |
| Boosting Converter Fail | Boost converter stopped | ON or OFF |
| Boosting Converter Shutdown Status | Boost converter shutdown status | Awake or Shutdown |
| Generator Carrier Frequency | Generator carrier frequency | 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode |
| Generator Control Mode | Generator (MG1) control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode |
| Motor Carrier Frequency | Motor (MG2) carrier frequency | 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode |
| Motor Control Mode | Motor (MG2) control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode |
| Boosting Converter Carrier Frequency | Boost converter signal carrier frequency | 9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.8 kHz |
| VL-Voltage before Boosting | High voltage before it is boosted | - |
| VH-Voltage after Boosting | High voltage after it is boosted | - |
| Boost Ratio | Boost converter boost ratio | Min.: 0.0%, Max.: 100.0% |
| V Phase Generator Current | V phase generator current | Min.: -3276.8 A, Max.: 3276.7 A |
| W Phase Generator Current | W phase generator current | Min.: -3276.8 A, Max.: 3276.7 A |
| V Phase Motor Current | V phase motor current | Min.: -3276.8 A, Max.: 3276.7 A |
| W Phase Motor Current | W phase motor current | Min.: -3276.8 A, Max.: 3276.7 A |
| Inverter Coolant Water Temperature | Inverter coolant temperature | Min.: -40°C (-40°F), Max.: 110°C (230°F) |
| Inverter Water Pump Duty Ratio | Inverter water pump motor driver request duty | Min.: 0.0%, Max.: 100.0% |
| Inverter Water Pump Revolution | Inverter water pump assembly speed | Min.: 0 rpm, Max.: 15000 rpm |
| Overvoltage Input to Inverter | Overvoltage detection into inverter | ON or OFF |
| Inverter Emergency Shutdown (Main CPU) | Inverter emergency shutdown | ON or OFF |
| Inverter Emergency Shutdown (Sub CPU) | Inverter emergency shutdown | ON or OFF |
| Inverter Input Current | Inverter input current | Min.: -3276.8 A, Max.: 3276.7 A |
| Overvoltage Input to Boosting Converter | Overvoltage detection into boost converter | ON or OFF |
| Motor/Generator Reactor Current before SMR Precharge | Motor/Generator reactor current before SMR precharge | Min.: -3276.8 A, Max.: 3276.7 A |
| Motor/Generator Reactor Maximum Current during SMR Precharge | Motor/Generator reactor maximum current during SMR precharge | Min.: -3276.8 A, Max.: 3276.7 A |
| Motor/Generator Reactor Current-Carrying Status during SMR Precharge | Motor/Generator reactor current-carrying status during SMR precharge | Indefinite / Definite |
| Motor/Generator Reactor Noncurrent-Carrying Status during SMR Precharge | Motor/Generator reactor noncurrent-carrying status during SMR precharge | Indefinite / Definite |
| Hybrid/EV Battery SOC | HV battery state of charge
Primary calculated from charging and discharging amperage |
Min.: 0.00%, Max.: 100.00% |
| Hybrid/EV Battery SOC of Immediately after IG ON | HV battery state of charge soon after ignition switch to ON | Min.: 0.0%, Max.: 100.0% |
| Hybrid/EV Battery Maximum SOC | Maximum SOC after ignition switch turned to ON in current trip | Min.: 0.0%, Max.: 100.0% |
| Hybrid/EV Battery Minimum SOC | Minimum SOC after ignition switch turned to ON in current trip | Min.: 0.0%, Max.: 100.0% |
| Hybrid/EV Battery Voltage | HV battery voltage | Min.: 0.00 V, Max.: 510.00 V |
| Hybrid/EV Battery Current | HV battery current | Min.: -3276.8 A, Max.: 3276.7 A |
| Hybrid/EV Battery Current for Driving Control | HVd battery current for driving control | Min.: -327.68 A, Max.: 327.67 A |
| Hybrid/EV Battery Cooling Fan Low Speed Request | Battery cooling blower assembly Lo speed requested | ON or OFF |
| Short Wave Highest Value Level | Waveform voltage level in abnormal insulation detection circuit in battery ECU assembly | Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3 |
| Insulation Resistance Division Check Completion using MG Inv | Insulation resistance division check completion using MG inverter | Not Complete / Complete |
| Insulation Resistance Division Check Completion using A/C Inv | Insulation resistance division check completion using A/C inverter | Not Complete / Complete |
| Insulation Resistance Division Check Completion using SMR | Insulation resistance division check completion using SMR | Not Complete / Complete |
| Short Wave Highest Value Availability just after MG Inv On/Off | Short wave highest value availability just after MG inverter on/off | No or Yes |
| Short Wave Highest Value Availability just after A/C Inv On/Off | Short wave highest value availability just after A/C inverter on/off | No or Yes |
| Short Wave Highest Value Availability just after SMR On/Off | Short wave highest value availability just after SMR on/off | No or Yes |
| Immobiliser Communication | Immobiliser communication line status | ON or OFF |
| Permit Start by Immobiliser | Status of starting permission by immobiliser (immobiliser to hybrid vehicle control ECU) | No Judgment / OK / NG |
| Auxiliary Battery Voltage | Auxiliary battery voltage | Min.: 0.00 V, Max.: 16.00 V |
| Auxiliary Battery Voltage just before SMR Precharge | Auxiliary battery voltage just before SMR precharge | Min.: -3276.8 A, Max.: 3276.7 A |
| Auxiliary Battery Current | Auxiliary battery current | Min.: -125.00 A, Max.: 124.99 A |
| Smoothed Value of Auxiliary Battery Temperature | Smoothed value of auxiliary battery temperature | Min.: -30.0°C (-22.0°F), Max.: 6513.5°C (11756.3°F) |
| Auxiliary Battery Status of Full Charge | Auxiliary battery status when full charge | Min.: 0.0 Ah, Max.: 127.5 Ah |
| Auxiliary Battery Charging Rate Accuracy | Auxiliary battery charging rate accuracy | Low / Middle / High / Disable |
| Power Feeding Electrical Using Status | Usage state of power supplied from external power source charging | Charge Sustaining Mode/Not PHV / Charge Depleting Mode / Charge Increasing Mode / Ready OFF |