If the cam position signal pulse sent from the ECM via a direct line is abnormal, the motor generator control ECU (MG ECU) (built into the inverter with converter assembly) stores DTC P034000 or P034031.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P034000 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor | GI signal (camshaft position sensor) is not input for 2 sec. or more while the engine is running*
(1 trip detection logic) |
·
SFI system ·
Inverter with converter assembly ·
ECM ·
Wire harness or connector |
Does not come on | Master Warning:
Comes on |
| P034031 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal | GI signal (camshaft position sensor) is not input for 2 sec. or more while the engine is running*
(1 trip detection logic) |
·
SFI system ·
Inverter with converter assembly ·
ECM ·
Wire harness or connector |
Does not come on | Master Warning:
Comes on |
*: When this DTC is stored, vibration may occur when the engine is stopped.
| DTC No. | Data List |
|---|---|
| P034000
P034031 |
·
Engine Speed ·
Crank Position (Hybrid control system) |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY).
With the vehicle stopped, move the shift lever to P.
Depress the accelerator pedal to start the engine.
Depress the accelerator pedal and maintain the engine speed at 1000 rpm or more for 5 seconds or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Procedure1
None.
Pre-procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs in the table below are output | A |
| Any of the DTCs in the table below are output | B |
| Relevant Diagnosis | |
|---|---|
| P034011 | Camshaft Position Sensor "A" Bank 1 or Single Sensor Circuit Short to Ground |
| P034015 | Camshaft Position Sensor "A" Bank 1 or Single Sensor Circuit Short to Battery or Open |
| P03402A | Camshaft Position Sensor "A" Bank 1 or Single Sensor Signal Stuck in Range |
| P034031 | Camshaft Position Sensor "A" Bank 1 or Single Sensor No Signal |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs in the table below are output | A |
| Any of the DTCs in the table below are output | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P0A1B1F | Generator Control Module Circuit Intermittent |
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message |
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid |
P034000 or P034031 may be stored due to a malfunction which also causes the DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 inverter with converter assembly connector.
Disconnect the A53 ECM connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector
(to ECM) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-10 (GI) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the inverter with converter assembly connector and ECM connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-10 (GI) - A53-23 (G2O) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-10 (GI) or A53-23 (G2O) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Post-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A53 ECM connector.
Reconnect the A56 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the A53 ECM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(ECM) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A53-23 (G2O) - A53-6 (E1) | Ignition switch off | 10 kΩ or higher |
Post-procedure1
Reconnect the A53 ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG