The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors its internal operation and detects malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P1C641F | Generator Control Module Circuit Intermittent | Excitation signal (REF signal) for resolver angle detection cycle malfunction detected when DTC P0C7917, P0E5717, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic) |
·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Wire harness or connector |
Does not come on | Master Warning:
Does not come on |
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | Generator resolver angle malfunction:
The difference between the resolver angle for control and estimated resolver angle exceeds the allowable limit. (1 trip detection logic) |
·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | Resolver REF signal cycle malfunction:
Excitation signal (REF signal) for resolver angle detection cycle malfunction (1 trip detection logic) |
·
Inverter with converter assembly ·
Hybrid vehicle transaxle assembly ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| DTC No. | Data List |
|---|---|
| P1CAC49 | Generator Revolution |
| P1CAF28 |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds or more.*
*: Lightly wiggle the connectors and wire harnesses up and down and right and left.
Turn the ignition switch to ON (READY) with the shift lever in P and wait for 5 seconds or more.
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.
Keep the engine running for 5 seconds or more.
Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.
Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.
If the resolver is malfunctioning, the vehicle may not drive smoothly.
When inspecting the connectors, if it is difficult to judge if a connector was disconnected, deformed or improperly secured, disconnect and reconnect the connector and then check for DTCs again. Check if the same DTC is output. If the same DTC is not output, improper connection of connectors is suspected.
As a malfunction detection threshold may be exceeded when performing the vibration or heat connector inspections, make sure to perform the following inspection to check that the DTC was not stored due to the malfunction of a part.
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P1CAC49, P1CAF38 or P1C641F is output | A |
| P1CAC49, P1CAF38 or P1C641F is output and DTCs other than the DTCs in the table below are output | B |
| P1CAC49, P1CAF38 or P1C641F is output and any DTCs in the table below are output | C |
| Relevant DTC | |
|---|---|
| P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold |
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open |
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open |
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Generator Resolver Circuit
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor Resolver Circuit
| Proceed to |
|---|
| NEXT |
NEXT