Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL SYSTEM
RM36W0E _51 Engine / Hybrid System _087936 HYBRID / BATTERY CONTROL _0420052 MOTOR GENERATOR CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM  P0A1B1F  Generator Control Module Circuit Intermittent  


DESCRIPTION

If the motor generator control ECU, which is built into in the inverter with converter assembly, is reset due to a problem with the power source in the inverter, the motor generator control ECU will stored this DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A1B1F Generator Control Module Circuit Intermittent Error in reset signal from the inverter assembly power source IC:
If internal power source voltage drops below the normal CPU operating voltage or the ROM/RAM is malfunctioning, the power source IC resets the MG ECU and stores this DTC.
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly

·

Auxiliary battery terminal


Comes on Master Warning:
Comes on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 2 minutes or more.

3.

Turn the ignition switch to ON and wait for 15 seconds or more.

4.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

A346382E33
0.135,1.167 1.01,1.625 0.875,0.458 10 false from Auxiliary Battery 1.385,1.354 2.24,1.542 0.854,0.188 10 false IGCT-MAIN 2.25,1.865 3.156,2.073 0.906,0.208 10 false IGCT-MAIN 3.458,1.417 4.031,1.604 0.573,0.188 10 false PCU FR 3.719,2.281 4.292,2.469 0.573,0.188 10 false MREL 3.646,3.24 4.219,3.427 0.573,0.188 10 false H44 3.635,3.396 4.563,3.781 0.927,0.385 10 false Hybrid Vehicle Control ECU 5.385,3.552 5.958,3.74 0.573,0.188 10 false A56 5.396,3.729 6.906,4.26 1.51,0.531 10 false Motor Generator Control ECU (Inverter with Converter Assembly) 5.708,1.885 6.281,2.073 0.573,0.188 10 false +B2 5.708,2.49 6.281,2.677 0.573,0.188 10 false GND1 5.708,3.177 6.281,3.365 0.573,0.188 10 false GND2 5.719,1.167 6.292,1.354 0.573,0.188 10 false +B 5.458,1.063 5.708,1.25 0.25,0.188 10 false 6 5.479,1.771 5.74,1.958 0.26,0.188 10 false 5 5.427,2.344 5.74,2.563 0.313,0.219 10 false 24 5.427,3.021 5.74,3.24 0.313,0.219 10 false 23 4.083,1.104 4.281,1.354 0.198,0.25 10 false 2 3.385,1.104 3.583,1.354 0.198,0.25 10 false 1 2.938,1.094 3.135,1.344 0.198,0.25 10 false 5 2.917,1.49 3.115,1.74 0.198,0.25 10 false 1 2.188,1.49 2.385,1.74 0.198,0.25 10 false 2 2.188,1.104 2.385,1.354 0.198,0.25 10 false 3 3.479,2.188 3.792,2.438 0.313,0.25 10 false 47

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C56
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




PROCEDURE

1.CHECK DTC OUTPUT

Pre-procedure1

a.

None.


Procedure1

b.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
Only P0A1B1F is output A
P0A1BF and hybrid control system DTCs in the table below are output B
P0A1BF and motor generator control system DTCs in the table below are output C


Malfunction Content System Relevant DTC
Communication malfunction Motor generator control system P312487 Lost Communication between Drive Motor "A" and HV ECU Missing Message
Hybrid control system P312387 Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message
U011087 Lost Communication with Drive Motor Control Module "A" Missing Message


Post-procedure1

c.

Turn the ignition switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

C

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

3.CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK AUXILIARY BATTERY TERMINAL (CONTACT PROBLEM)
a.

Check the connection of the auxiliary battery terminal.

OK:

The terminal is connected securely and there is no contact problem.



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT-MAIN RELAY)

NG

CONNECT SECURELY

4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT-MAIN RELAY)
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Disconnect the A56 inverter with converter assembly connector.


c.

Remove the IGCT-MAIN relay from the No. 5 relay block assembly.


Procedure1

d.

Measure the resistance according to the value(s) in the table below.

A459951C04
4.844,0.25 5.229,0.521 0.385,0.271 5.25,1.24 5.74,0.521 true 5.385,1.24 6.198,0.813 true 4.656,2.417 5.24,1.573 true 5.385,1.552 5.938,2.385 true 0.333,0.198 0.646,0.396 0.313,0.198 10 false *1 0.948,1.646 1.26,1.844 0.313,0.198 10 false *2 3.885,0.188 4.198,0.385 0.313,0.198 10 false *a 5.813,0.417 6.271,0.615 0.458,0.198 10 false +B2 6.281,0.729 6.594,0.927 0.313,0.198 10 false +B 4.469,2.458 5.083,2.656 0.615,0.198 10 false GND2 5.844,2.458 6.458,2.656 0.615,0.198 10 false GND1 4.927,0.313 5.385,0.51 0.458,0.198 10 false A56
*1 No. 5 Relay Block Assembly *2 IGCT-MAIN Relay Holder
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
A56-6 (+B) - 5 (IGCT-MAIN relay holder) Ignition switch off Below 1 Ω
A56-5 (+B2) - 5 (IGCT-MAIN relay holder) Ignition switch off Below 1 Ω
A56-24 (GND1) - Body ground Ignition switch off Below 1 Ω
A56-23 (GND2) - Body ground Ignition switch off Below 1 Ω



Post-procedure1

e.

Install the IGCT-MAIN relay.


f.

Reconnect the A56 inverter with converter assembly connector.


Result:
Proceed to
OK
NG



OK

5.CHECK FOR INTERMITTENT PROBLEMS

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK FOR INTERMITTENT PROBLEMS
a.

Check for intermittent problems.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>CHECK FOR INTERMITTENT PROBLEMS


i.

Check the connection and terminal contact pressure of the connectors and wire harnesses between the auxiliary battery and the inverter with converter assembly.

Result:

There are no abnormalities in the wire harnesses and connectors.




Result:
Proceed to
OK
NG



OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA