Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM
RM36W0E _51 Engine / Hybrid System _087936 HYBRID / BATTERY CONTROL _0420053 HYBRID BATTERY SYSTEM L

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  PRECAUTION  


PRECAUTIONS FOR INSPECTING HYBRID BATTERY SYSTEM


a.
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

·

Inspecting the high-voltage system

·

Disconnecting the low voltage connector of the inverter with converter assembly

·

Disconnecting the low voltage connector of the HV battery


A458473E01
2.344,1.656 2.469,1.813 0.125,0.156 10 true 1 1.479,1.24 1.604,1.396 0.125,0.156 10 true 2 4.823,1.708 4.938,1.865 0.115,0.156 10 true 3

NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

After removing the service plug grip, turning the ignition switch to ON (READY) may cause a malfunction. Do not turn the ignition switch to ON (READY) unless instructed by the repair manual.




b.
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.


c.
A358042

After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.


d.
A357589C04
1.563,0.708 1.813,0.417 true 1.844,0.302 2.156,0.5 0.313,0.198 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.



e.

Check the voltage at the terminals in the inspection point in the inverter with converter assembly.

CAUTION:

Be sure to wear insulated gloves.


i.
A458474

Remove the connector cover assembly from the inverter with converter assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




ii.
A458475

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
Inspection point At least 10 minutes after removing the service plug grip 0 V


HINT:

Set the tester to DC750 V or more to measure the voltage.



iii.

Reinstall the connector cover assembly.



f.
A358019

w/ Entry and Start System:

When turning the ignition switch to ON during an inspection, do not press the ignition switch with the brake pedal depressed.

CAUTION:

Pressing the ignition switch with the brake pedal depressed causes the system to enter the READY-on state. This is very dangerous because high voltage may be applied to the inspection area.



g.
C414532

w/o Smart Key System:

When turning the ignition switch to ON during inspections, do not turn the ignition switch to START.

CAUTION:

Turning the ignition switch to START causes the system to enter the READY-on state. This is very dangerous because high voltage may be applied to the inspection area.



h.

Turn the ignition switch off, wear insulated gloves, and disconnect the cable from the negative (-) terminal of the auxiliary battery before touching any of the orange-colored wires of the high-voltage system.

NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART





i.

Turn the ignition switch off before performing any resistance checks.


j.

Turn the ignition switch off before disconnecting or reconnecting any connectors.


k.

When performing work involving high-voltage wires, use either a tool wrapped with vinyl insulation tape or an insulated tool.


l.

When high-voltage connectors are removed, wrap the connectors with insulation tape to prevent them from contacting foreign matter.



NOTICE FOR HYBRID BATTERY SYSTEM ACTIVATION


a.

When the warning is illuminated, or the auxiliary battery has been disconnected and reconnected, attempting to turn the ignition switch to ON (READY) may not start the system (the system may not enter the READY-on state) on the first attempt. If so, turn the ignition switch off and reattempt to start the hybrid system.

NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART






PRECAUTIONS FOR DISCONNECTING AMD TERMINAL


HINT:

The AMD terminal is connected to the positive terminal of the auxiliary battery. To prevent damage when the AMD terminal is being disconnected, use the following procedure.


a.
A434722C03
0.792,1.083 0.396,0.698 true 2.469,0.542 2.146,0.396 true 0.219,0.469 0.531,0.667 0.313,0.198 10 true *1 1.99,0.198 2.302,0.396 0.313,0.198 10 true *2
*1 AMD Terminal (Inverter with Converter Assembly Side)
*2 AMD Terminal (No. 1 Engine Room Relay Block Side)


Be sure to disconnect the cable from the negative (-) auxiliary battery terminal before disconnecting the AMD terminal from the No. 1 engine room relay block.

NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART





b.

After disconnecting the AMD terminal, wrap it with vinyl insulating tape.


c.

Be sure to reconnect the AMD terminal to the No. 1 engine room relay block before reconnecting the cable to the negative (-) terminal of the auxiliary battery.

NOTICE:

A short circuit to ground may occur if the AMD terminal is disconnected before the cable is disconnected from the negative (-) auxiliary battery terminal. If a short circuit to ground occurs, a fusible link or fuse may break.




DISPOSING OF HV BATTERY AND HV SUPPLY STACK SUB-ASSEMBLY


a.

When disposing of HV batteries and HV supply stack sub-assemblies, make sure to return them through an authorized collection agent who is capable of handling them safely. If they are returned via the manufacturer specified route, they will be returned properly and in a safe manner by an authorized collection agent.

CAUTION:
·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.

·
A358021C04
0.552,4.156 0.865,4.354 0.313,0.198 10 false *a 2.76,4.167 3.073,4.365 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned.

Therefore, make sure to return HV battery through an authorized collection agent.

·

To reduce the risk of fire, HV battery must not be stored in an area where they will be exposed to fire or high temperatures.

·

If the temperature of the HV battery is high, leave the vehicle until the temperature drops.

·

Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.

·

Before returning the HV battery, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION

·

Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>RECOVERY INSPECTION





PRECAUTIONS WHEN REPLACING HYBRID VEHICLE CONTROL ECU


NOTICE:

Before replacing the hybrid vehicle control ECU, refer to Service Bulletin.



PRECAUTION WHEN REPLACING BATTERY ECU ASSEMBLY AND ECM


HV battery learning values are stored in the battery ECU assembly and ECM to display "HAVE TRACTION BATTERY INSPECTED" on the multi-information display. When either of these ECUs is replaced, the new ECU receives the HV battery learning value data from the other ECU and updates the information.

NOTICE:
·

Do not replace the battery ECU assembly and ECM at the same time as it clears the HV battery learning values. However, if it is necessary to replace both ECUs at the same time, replace them by following the procedure below.

·

Do not replace the battery ECU assembly or ECM with used ones from other vehicles.



a.

Procedure when replacing both battery ECU assembly and ECM:

i.

Disconnect the cable from the negative (-) auxiliary battery terminal.


ii.

Replace either of the ECUs.


iii.

Connect the cable to the negative (-) auxiliary battery terminal.


iv.

Turn the ignition switch to ON (READY) and wait for 5 minutes or more.


v.

Turn the ignition switch off and disconnect the cable from the negative (-) auxiliary battery terminal.


vi.

Replace the other ECU.


vii.

Connect the cable to the negative (-) auxiliary battery terminal.


viii.

Check that the ignition switch can be turned ON (READY).




HINT:

If the battery ECU assembly and ECM are replaced at the same time without following the above procedure, replace either of the ECUs with its original one and then replace it again by following the above procedure. If the correct procedure is not followed, perform the procedure again from the beginning.


DISCONNECTING AND RECONNECTING NEGATIVE AUXILIARY BATTERY CABLE


D105639C01
0.635,0.406 0.885,0.406 0.885,0.406 1.552,0.708 false 1.885,1.313 2.458,1.031 2.458,1.031 2.656,1.031 false 0.479,0.323 0.792,0.521 0.313,0.198 10 *1 2.708,0.958 3.021,1.156 0.313,0.198 10 *2
*1 Cable
*2 Negative (-) Auxiliary Battery Terminal


a.

Before performing work on electronic components, disconnect the cable from the negative (-) auxiliary battery terminal to prevent damage to the electrical system or electrical components.


b.

Before disconnecting and reconnecting the auxiliary battery cable, turn the ignition switch off and the headlight switch off. Then loosen the terminal nut completely. Do not damage the cable or terminal.


c.

When the auxiliary battery cable is disconnected, the clock and radio settings and stored DTCs are cleared. Therefore, before disconnecting the auxiliary battery cable, make a note of them.

NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART