CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


E417909N01
2.792,0.5 3.208,0.75 0.417,0.25 3.813,0.5 4.229,0.75 0.417,0.25 4.729,0.5 5.146,0.75 0.417,0.25 3.906,0.563 4.26,0.802 0.354,0.24 10 false H24 2.896,0.563 3.25,0.802 0.354,0.24 10 false H25 4.875,0.552 5.229,0.792 0.354,0.24 10 false h6

a.

Check air conditioning amplifier assembly.

i.

Disconnect the H24 air conditioning amplifier assembly connector.


ii.

Measure the voltage and resistance according to the value(s) in the table below.

Standard:
Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H24-5 (B) - H24-17 (GND) Power source Always 11 to 14 V
H24-6 (IG+) - H24-17 (GND) Power source (IG) Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
H24-17 (GND) - Body ground Ground for main power supply Always Below 1 Ω


iii.

Connect the H24 air conditioning amplifier assembly connector.


iv.

Measure the voltage, resistance and waveform according to the value(s) in the table below.

Standard:
Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H25-3 (SG-1) - Body ground Ground for cooler (room temp. sensor) thermistor Always Below 1 Ω
H25-5 (TR) - H24-17 (GND) Cooler (room temp. sensor) thermistor signal
·

Ignition switch ON

·

Cabin temperature: 25°C (77°F)


1.05 to 1.45 V
H25-6 (PRE) - H24-17 (GND) Air conditioner pressure sensor signal
·

Ignition switch ON

·

Air conditioning system operating

·

Refrigerant pressure: Normal pressure (less than 3.025 MPaG [30.8 kgf/cm2, 439 psi]) and 0.176 MPaG [1.8 kgf/cm2, 26 psi] or higher)


Less than 4.73 V and 0.62 V or higher*1
·

Ignition switch ON

·

Air conditioning system operating

·

Refrigerant pressure: Abnormal pressure (3.025 MPaG [30.8 kgf/cm2, 439 psi] or higher)


4.73 V or higher*1
·

Ignition switch ON

·

Air conditioning system operating

·

Refrigerant pressure: Abnormal pressure (less than 0.176 MPaG [1.8 kgf/cm2, 26 psi])


Less than 0.62 V*1
H25-11 (S5-3) - H24-17 (GND) Power supply for air conditioner pressure sensor Ignition switch ON 4.75 to 5.25 V
Ignition switch off Below 1 V
H25-15 (SG-4) - Body ground Ground for air conditioner pressure sensor Always Below 1 Ω
H24-1 (CANL) - H24-17 (GND) CAN communication system Ignition switch ON Pulse generation
H24-2 (CANH) - H24-17 (GND) CAN communication system Ignition switch ON Pulse generation
H24-7 (LIN1) - H24-17 (GND) LIN communication signal Ignition switch ON Pulse generation
(See waveform 1)
H24-18 (SOL+) - H24-17 (GND) Compressor solenoid operation signal
·

Engine running

·

Blower switch: On

·

A/C switch: On


Pulse generation
(See waveform 2)
H24-21 (BLW) - H24-17 (GND) Blower motor speed control signal
·

Ignition switch ON

·

Blower switch: LO


Pulse generation
(See waveform 3)
h6-2 (BUSG) - Body ground Ground for BUS IC Always Below 1 Ω
h6-3 (BUS) - h6-2 (BUSG) BUS IC control signal Ignition switch ON Pulse generation
(See waveform 4)
h6-4 (BUSB) - h6-2 (BUSG) Power supply for BUS IC Always 11 to 14 V
h6-5 (SG-3) - Body ground Ground for No. 1 cooler thermistor Always Below 1 Ω
h6-6 (TE) - h6-5 (SG-3) No. 1 cooler thermistor signal
·

Ignition switch ON

·

Evaporator temperature: 0°C (32°F)


1.7 to 2.1 V
·

Ignition switch ON

·

Evaporator temperature: 15°C (59°F)


0.9 to 1.3 V

*1: While sensor voltage is 5 V.



b.
E334619N02
0.313,1.563 0.771,1.76 0.458,0.198 10 false GND

Waveform 1:

Item Content
Terminal No. H24-7 (LIN1) - H24-17 (GND)
Tool Setting 2 V/DIV., 20 ms./DIV.
Condition Ignition switch ON


c.
E145424N07
2.979,1.271 3.354,1.438 0.375,0.167 10 false GND

Waveform 2:

Item Content
Terminal No. H24-18 (SOL+) - H24-17 (GND)
Tool Setting 5 V/DIV., 500 μs./DIV.
Condition
·

Engine running

·

Blower switch: On

·

A/C switch: On




d.
E338778N01
2.823,1.24 3.281,1.438 0.458,0.198 10 false GND

Waveform 3:

Item Content
Terminal No. H24-21 (BLW) - H24-17 (GND)
Tool Setting 2 V/DIV., 1 ms./DIV.
Condition
·

Ignition switch ON

·

Blower switch: LO



HINT:

The waveform varies with the blower speed.



e.
E202803N05
0.333,1.469 0.75,1.646 0.417,0.177 10 GND

Waveform 4:

Item Content
Terminal No. h6-3 (BUS) - h6-2 (BUSG)
Tool Setting 2 V/DIV., 2 ms./DIV.
Condition Ignition switch ON



CHECK AIR CONDITIONING CONTROL ASSEMBLY


E389743N04
3.375,0.167 3.792,0.417 0.417,0.25 3.479,0.229 3.792,0.448 0.313,0.219 10 false H31

a.

Disconnect the H31 air conditioning control assembly connector.


b.

Measure the voltage, resistance and waveform according to the value(s) in the table below.

Standard:
Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H31-7 (LIN1) - Body ground LIN communication signal Ignition switch ON Pulse generation
(See waveform 1)
H31-8 (ILL+) - Body ground Illumination signal Taillight off Below 1 V
Taillight on 11 to 14 V
H31-9 (IG+) - H31-13 (GND) Power source (IG) Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
H31-13 (GND) - Body ground Ground for air conditioning control assembly Always Below 1 Ω
H31-14 (ILL-) - Body ground Illumination signal Always Below 1 V


c.
E202803N05
0.333,1.469 0.75,1.646 0.417,0.177 10 GND

Waveform 1:

Item Content
Terminal No. H31-7 (LIN1) - Body ground
Tool Setting 2 V/DIV., 20 ms./DIV.
Condition Ignition switch ON