CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Check air conditioning amplifier assembly.
Disconnect the H24 air conditioning amplifier assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H24-5 (B) - H24-17 (GND) | Power source | Always | 11 to 14 V |
| H24-6 (IG+) - H24-17 (GND) | Power source (IG) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | ||
| H24-17 (GND) - Body ground | Ground for main power supply | Always | Below 1 Ω |
Connect the H24 air conditioning amplifier assembly connector.
Measure the voltage, resistance and waveform according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H25-3 (SG-1) - Body ground | Ground for cooler (room temp. sensor) thermistor | Always | Below 1 Ω |
| H25-5 (TR) - H24-17 (GND) | Cooler (room temp. sensor) thermistor signal | ·
Ignition switch ON ·
Cabin temperature: 25°C (77°F) |
1.05 to 1.45 V |
| H25-6 (PRE) - H24-17 (GND) | Air conditioner pressure sensor signal | ·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Normal pressure (less than 3.025 MPaG [30.8 kgf/cm2, 439 psi]) and 0.176 MPaG [1.8 kgf/cm2, 26 psi] or higher) |
Less than 4.73 V and 0.62 V or higher*1 |
·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (3.025 MPaG [30.8 kgf/cm2, 439 psi] or higher) |
4.73 V or higher*1 | ||
·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (less than 0.176 MPaG [1.8 kgf/cm2, 26 psi]) |
Less than 0.62 V*1 | ||
| H25-11 (S5-3) - H24-17 (GND) | Power supply for air conditioner pressure sensor | Ignition switch ON | 4.75 to 5.25 V |
| Ignition switch off | Below 1 V | ||
| H25-15 (SG-4) - Body ground | Ground for air conditioner pressure sensor | Always | Below 1 Ω |
| H24-1 (CANL) - H24-17 (GND) | CAN communication system | Ignition switch ON | Pulse generation |
| H24-2 (CANH) - H24-17 (GND) | CAN communication system | Ignition switch ON | Pulse generation |
| H24-7 (LIN1) - H24-17 (GND) | LIN communication signal | Ignition switch ON | Pulse generation
(See waveform 1) |
| H24-18 (SOL+) - H24-17 (GND) | Compressor solenoid operation signal | ·
Engine running ·
Blower switch: On ·
A/C switch: On |
Pulse generation
(See waveform 2) |
| H24-21 (BLW) - H24-17 (GND) | Blower motor speed control signal | ·
Ignition switch ON ·
Blower switch: LO |
Pulse generation
(See waveform 3) |
| h6-2 (BUSG) - Body ground | Ground for BUS IC | Always | Below 1 Ω |
| h6-3 (BUS) - h6-2 (BUSG) | BUS IC control signal | Ignition switch ON | Pulse generation
(See waveform 4) |
| h6-4 (BUSB) - h6-2 (BUSG) | Power supply for BUS IC | Always | 11 to 14 V |
| h6-5 (SG-3) - Body ground | Ground for No. 1 cooler thermistor | Always | Below 1 Ω |
| h6-6 (TE) - h6-5 (SG-3) | No. 1 cooler thermistor signal | ·
Ignition switch ON ·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
·
Ignition switch ON ·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V |
*1: While sensor voltage is 5 V.
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | H24-7 (LIN1) - H24-17 (GND) |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |
Waveform 2:
| Item | Content |
|---|---|
| Terminal No. | H24-18 (SOL+) - H24-17 (GND) |
| Tool Setting | 5 V/DIV., 500 μs./DIV. |
| Condition | ·
Engine running ·
Blower switch: On ·
A/C switch: On |
Waveform 3:
| Item | Content |
|---|---|
| Terminal No. | H24-21 (BLW) - H24-17 (GND) |
| Tool Setting | 2 V/DIV., 1 ms./DIV. |
| Condition | ·
Ignition switch ON ·
Blower switch: LO |
The waveform varies with the blower speed.
Waveform 4:
| Item | Content |
|---|---|
| Terminal No. | h6-3 (BUS) - h6-2 (BUSG) |
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Condition | Ignition switch ON |
CHECK AIR CONDITIONING CONTROL ASSEMBLY
Disconnect the H31 air conditioning control assembly connector.
Measure the voltage, resistance and waveform according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H31-7 (LIN1) - Body ground | LIN communication signal | Ignition switch ON | Pulse generation
(See waveform 1) |
| H31-8 (ILL+) - Body ground | Illumination signal | Taillight off | Below 1 V |
| Taillight on | 11 to 14 V | ||
| H31-9 (IG+) - H31-13 (GND) | Power source (IG) | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | ||
| H31-13 (GND) - Body ground | Ground for air conditioning control assembly | Always | Below 1 Ω |
| H31-14 (ILL-) - Body ground | Illumination signal | Always | Below 1 V |
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | H31-7 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |