DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Total distance traveled | Min.: 0
Max.: 999999 |
Actual total distance displayed | - |
| Total Distance Traveled - Unit | Total distance traveled unit | km or mile | - | - |
| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual cabin temperature displayed | Cooler (room temp. sensor) thermistor circuit malfunction |
| Ambient Temperature Sensor | Thermistor assembly | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual ambient temperature displayed | Thermistor assembly circuit malfunction |
| Front Left Solar Sensor | Automatic light control sensor | Min.: 0 W/m^2
Max.: 6553.5 W/m^2 |
Automatic light control sensor value increases as brightness increases | Automatic light control sensor circuit malfunction |
| Front Right Solar Sensor | - | - | - | This item is displayed on the GTS but is not used. |
| Engine Coolant Temperature Sensor | Engine coolant temperature sensor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual engine coolant temperature displayed | ·
SFI system malfunction ·
CAN communication system malfunction |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor circuit malfunction |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32.768 MPaG
Max.: 32.767 MPaG |
Actual refrigerant pressure displayed | ·
Refrigerant line(gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Ambient Temperature Adjustment Value | Adjusted ambient temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Adjust ambient temperature displayed | Air conditioning amplifier assembly circuit malfunction |
| Front Right Air Outlet Temperature | Driver side target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Driver side target temperature displayed | ·
When MAX COLD: -327.68°C (-557.82°F) ·
When MAX HOT: 327.67°C (621.81°F) |
| Front Left Air Outlet Temperature | - | - | - | This item is displayed on the GTS but is not used. |
| Evaporator Target Temperature | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | No. 1 cooler thermistor circuit malfunction
·
When open circuit: -327.68°C (-557.82°F) ·
When short circuit: 327.67°C (621.81°F) |
| Front Right Set Temperature | Driver side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Driver side set temperature displayed | Air conditioning control assembly circuit malfunction |
| Front Left Set Temperature | - | - | - | This item is displayed on the GTS but is not used. |
| Front Left Air Mix Damper Control Servo Motor Target Pulse | - | - | - | This item is displayed on the GTS but is not used. |
| Front Left Air Mix Damper Control Servo Motor Actual Pulse | - | - | - | This item is displayed on the GTS but is not used. |
| Front Right Air Mix Damper Control Servo Motor Target Pulse | - | - | - | This item is displayed on the GTS but is not used. |
| Front Right Air Mix Damper Control Servo Motor Actual Pulse | - | - | - | This item is displayed on the GTS but is not used. |
| Air Inlet Damper Control Servo Motor Target Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128
Max.: 384 |
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128
Max.: 384 |
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Front Air Mix Damper Control Servo Motor Target Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128
Max.: 384 |
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Air Mix Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128
Max.: 384 |
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Air Outlet Damper Control Servo Motor Target Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128
Max.: 384 |
·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT: 297 (pulse) ·
FOOT/DEF 320 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Air Outlet Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128
Max.: 384 |
·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT: 297 (pulse) ·
FOOT/DEF 320 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Solenoid Valve Control Current Value | Solenoid valve control current | Min.: 0 mA
Max.: 1000 mA |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| PTC Request Count | - | - | - | This item is displayed on the GTS but is not used. |
| PTC Actual Driving Count | - | - | - | This item is displayed on the GTS but is not used. |
| Refrigerant Gas Type | Refrigerant gas type | R134a or Hfo1234yf | Refrigerant gas type displayed | - |
| PTC Driving Maximum Level | - | - | - | This item is displayed on the GTS but is not used. |
| Refrigerant High Pressure History Count | Refrigerant high pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant high pressure history stored displayed | *1 |
| Refrigerant Low Pressure History Count | Refrigerant low pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant low pressure history stored displayed | *1 |
| Operation Limit Control History Count | Operation limit control history | Min.: 0
Max.: 255 |
Number of times operation limit control history stored displayed | *2 |
| Air Inlet Change Auto Switch Interlock | Air inlet mode | Manual or Automatic | Customized value displayed | - |
| Foot/DEF Automatic Blow Up Function | Foot/defroster auto blower speed increase | OFF or ON | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/defroster auto mode | OFF or ON | Customized value displayed | - |
| ECO Mode Control | Function to cancel ECO mode when set to ON | OFF or ON | Customized value displayed | - |
| Fan Speed Increment Control | Fan speed increment control | Short, Normal or Long | Customized value displayed | - |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function | OFF or ON | Customized value displayed | - |
| Evaporator Control | Evaporator control | Manual or Automatic | Customized value displayed | - |
| Ion Generate Control | - | - | - | This item is displayed on the GTS but is not used. |
| Set Temperature Shift | Shift set temperature | Min.: -2 °C
Max.: 2 °C |
Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check | OFF or ON | Customized value displayed | - |
| Blower Level | Blower motor speed level | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Blower motor with fan sub-assembly circuit malfunction |
| PTC Heater | - | - | - | This item is displayed on the GTS but is not used. |
| A/C Driving Demand | A/C control cutoff signal | ON or OFF | The ECM sends the air conditioning control cutoff signal displayed | ECM circuit malfunction |
| Electrical Fan | Electric cooling fan motor status | ON or OFF | Status of electric cooling fan motor displayed | - |
| Ion Generator | Ion generator status | ON or OFF | Status of ion generator displayed | - |
*1: Refer to the following procedure to clear the refrigerant pressure history.
*2: Refer to the following procedure to clear the A/C operation limit history count.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F)
Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Level | Blower motor with fan sub-assembly | Min.: 0
Max.: 31 |
- |
| PTC Heater | - | - | This item is displayed on the GTS but is not used. |
| A/C Driving Demand | Air conditioning system | OFF or ON | - |
| Electrical Fan | Electric cooling fan motor | OFF or ON | - |
| Ion Generator | - | - | This item is displayed on the GTS but is not used. |
| Front Left Air Mix Damper Control Servo Motor | - | - | This item is displayed on the GTS but is not used. |
| Front Right Air Mix Damper Control Servo Motor | - | - | This item is displayed on the GTS but is not used. |
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Front Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Front Air Outlet Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |