The No. 1 cooler thermistor is installed to the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| P053511 | Evaporator Temperature Sensor Circuit Short to Ground | Diagnosis Condition:
Ignition switch ON Malfunction Status: Short in evaporator temperature sensor circuit Detection Time: Continuously for 4 seconds or more |
·
No. 1 cooler thermistor ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
Memorized |
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor circuit malfunction |
| Tester Display |
|---|
| Evaporator Fin Thermistor |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Remove the air conditioning harness assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| h5-1 or h6-5 (SG-3) - Other terminals and body ground | Always | 10 kΩ or higher |
| h5-2 or h6-6 (TE) - Other terminals and body ground | Always | 10 kΩ or higher |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG