Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System) › 2020.03–2020.07
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0420298 AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  B143A87  Lost Communication with Air Inlet Damper Control Servo Motor LIN Missing Message  


DESCRIPTION

The air conditioning harness assembly and No. 1 air conditioning radiator damper servo sub-assembly connect the air conditioning amplifier assembly and the No. 1 blower damper servo sub-assembly. The air conditioning amplifier assembly supplies power and sends operation instructions to No. 1 blower damper servo sub-assembly through the air conditioning harness assembly and No. 1 air conditioning radiator damper servo sub-assembly. The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B143A87 Lost Communication with Air Inlet Damper Control Servo Motor LIN Missing Message Diagnosis Condition:

Ignition switch ON


Malfunction Status:

Error or lost communication with No. 1 blower damper servo sub-assembly


Detection Time:

Continuously for 10 seconds or more


·

No. 1 blower damper servo sub-assembly

·

Air conditioning harness assembly


Memorized

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Ignition switch ON ○ ○
Malfunction Error communication with No. 1 blower damper servo sub-assembly ○ -
Lost communication with No. 1 blower damper servo sub-assembly - ○
Detection Time Continuously for 10 seconds or more Continuously for 10 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored.


WIRING DIAGRAM

E437384E01
2.292,1.823 2.656,2.01 0.365,0.188 10 false IC 5.521,6.688 6.083,6.885 0.563,0.198 10 false h6 5.51,6.865 7.073,7.188 1.563,0.323 10 false Air Conditioning Amplifier Assembly 3.104,6.771 5.448,7.177 2.344,0.406 10 false Air Conditioning Harness Assembly 0.219,6.979 3.177,7.333 2.958,0.354 10 false No. 1 Blower Damper Servo Sub-assembly 0.156,4.844 2.938,5.177 2.781,0.333 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.729,3.5 1.427,3.781 0.698,0.281 10 false Mode 0.656,1.5 1.271,1.729 0.615,0.229 10 false Air Mix 5.542,1.677 6.104,1.875 0.563,0.198 10 false BUSG 5.542,1.104 6.104,1.302 0.563,0.198 10 false BUS 5.542,0.5 6.104,0.698 0.563,0.198 10 false BUSB 6.76,1.198 7,1.396 0.24,0.198 10 false IC 5.354,0.49 5.656,0.698 0.302,0.208 10 false 4 5.354,1.042 5.656,1.25 0.302,0.208 10 false 3 5.354,1.677 5.656,1.885 0.302,0.208 10 false 2 0.781,7.469 3.083,7.844 2.302,0.375 10 false : LIN Communication Line 6.448,0.323 6.771,0.51 0.323,0.188 10 false +B 2.594,2.781 3.208,2.979 0.615,0.198 10 false STE2 2.594,2.99 3.208,3.188 0.615,0.198 10 false STE1 2.75,3.188 3.365,3.385 0.615,0.198 10 false M- 2.646,5.573 3.26,5.771 0.615,0.198 10 false GND 2.74,5.781 3.354,5.979 0.615,0.198 10 false M+ 2.75,5.979 3.365,6.177 0.615,0.198 10 false M- 2.656,6.156 3.271,6.354 0.615,0.198 10 false sigA 2.667,6.365 3.281,6.563 0.615,0.198 10 false sigB 3.031,2.677 3.333,2.885 0.302,0.208 10 false 3 3.031,2.885 3.333,3.094 0.302,0.208 10 false 4 3.031,3.094 3.333,3.302 0.302,0.208 10 false 1 3.031,3.667 3.333,3.875 0.302,0.208 10 false 2 3.031,3.875 3.333,4.083 0.302,0.208 10 false 5 3.031,5.552 3.333,5.76 0.302,0.208 10 false 1 3.031,5.771 3.333,5.979 0.302,0.208 10 false 4 3.042,5.969 3.344,6.177 0.302,0.208 10 false 5 3.042,6.167 3.344,6.375 0.302,0.208 10 false 2 3.042,6.365 3.344,6.573 0.302,0.208 10 false 3 2.729,3.677 3.344,3.875 0.615,0.198 10 false M+ 2.646,3.875 3.26,4.073 0.615,0.198 10 false GND 0.167,4.677 0.781,4.875 0.615,0.198 10 false h7 0.24,6.781 0.854,6.979 0.615,0.198 10 false h4 2.646,1.76 3,1.958 0.354,0.198 10 false GND 2.719,1.177 3.073,1.375 0.354,0.198 10 false LIN 2.76,0.594 3.031,0.802 0.271,0.208 10 false +B 3.021,1.042 3.24,1.26 0.219,0.219 10 false 7 3.021,0.479 3.219,0.635 0.198,0.156 10 false 8 3.031,1.677 3.24,1.865 0.208,0.188 10 false 6

PROCEDURE

1.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 450

Result:
Result Proceed to
B142A88 is output A
B142A88 is not output B



A

B

2.INSPECT AIR CONDITIONING HARNESS ASSEMBLY
2.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

Pre-procedure1

a.

Disconnect the h7 No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Disconnect the h4 No. 1 blower damper servo sub-assembly connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
h7-1 (M-) - h4-5 (M-) Always Below 1 Ω
h7-2 (M+) - h4-4 (M+) Always Below 1 Ω
h7-3 (STE2) - h4-3 (sigB) Always Below 1 Ω
h7-4 (STE1) - h4-2 (sigA) Always Below 1 Ω
h7-5 (GND) - h4-1 (GND) Always Below 1 Ω
h7-1 (M-) or h4-5 (M-) - Other terminals and body ground Always 10 kΩ or higher
h7-2 (M+) or h4-4 (M+) - Other terminals and body ground Always 10 kΩ or higher
h7-3 (STE2) or h4-3 (sigB) - Other terminals and body ground Always 10 kΩ or higher
h7-4 (STE1) or h4-2 (sigA) - Other terminals and body ground Always 10 kΩ or higher



Post-procedure1

d.

None


Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY