CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Check air conditioning amplifier assembly.
Disconnect the H23 air conditioning amplifier assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H23-1 (B) - H23-27 (GND) | Power source | Always | 11 to 14 V |
| H23-19 (IG+) - H23-27 (GND) | Power source (IG) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | ||
| H23-27 (GND) - Body ground | Ground for main power supply | Always | Below 1 Ω |
Connect the H23 air conditioning amplifier assembly connector.
Measure the voltage, resistance and waveform according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H23-4 (LED) - H23-27 (GND) | A/C switch indicator signal | ·
Ignition switch ON ·
A/C switch: On ·
Blower switch: On |
Below 1 V |
·
Ignition switch ON ·
A/C switch: Off ·
Blower switch: On |
11 to 14 V | ||
| H23-9 (CANH) - H23-27 (GND) | CAN communication system | Ignition switch ON | Pulse generation |
| H23-11 (S5-3) - H23-27 (GND) | Power supply for air conditioner pressure sensor | Ignition switch ON | 4.75 to 5.25 V |
| Ignition switch off | Below 1 V | ||
| H23-12 (SG-4) - Body ground | Ground for air conditioner pressure sensor | Always | Below 1 Ω |
| H23-13 (TE) - H23-14 (SG-3) | No. 1 cooler thermistor signal | ·
Ignition switch ON ·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
·
Ignition switch ON ·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V | ||
| H23-14 (SG-3) - Body ground | Ground for No. 1 cooler thermistor | Always | Below 1 Ω |
| H23-15 (SBLW) - H23-27 (GND) | Blower motor operation condition signal | ·
Ignition switch ON ·
Blower switch: On |
Below 1 V |
·
Ignition switch ON ·
Blower switch: Off |
11 to 14 V | ||
| H23-17 (DEF) - H23-27 (GND) | Defogger sensing signal | ·
Ignition switch ON ·
Airflow mode control switch is set to DEF/FOOT or DEF: On |
11 to 14 V |
·
Ignition switch ON ·
Airflow mode control switch is set to FACE, FACE/FOOT or FOOT: Off |
Below 1 V | ||
| H23-20 (SOL+) - H23-27 (GND) | Compressor solenoid operation signal | ·
Engine running ·
Blower switch: On ·
A/C switch: On |
Pulse generation
(See waveform 1) |
| H23-21 (HR) - H23-27 (GND) | Heater relay operation signal | ·
Ignition switch ON ·
Blower switch: LO |
Below 1 V |
·
Ignition switch ON ·
Blower switch: Off |
11 to 14 V | ||
| H23-26 (CANL) - H23-27 (GND) | CAN communication system | Ignition switch ON | Pulse generation |
| H23-30 (HEAT) - H23-27 (GND) | Max hot sensing signal | ·
Ignition switch ON ·
MAX HOT position |
11 to 14 V |
·
Ignition switch ON ·
Other than MAX HOT position |
Below 1 V | ||
| H23-31 (COOL) - H23-27 (GND) | Max cool sensing signal | ·
Ignition switch ON ·
MAX COOL position |
11 to 14 V |
·
Ignition switch ON ·
Other than MAX COOL position |
Below 1 V | ||
| H23-32 (A/C) - H23-27 (GND) | A/C switch signal | ·
Ignition switch ON ·
A/C switch: On |
11 to 14 V |
·
Ignition switch ON ·
A/C switch: Off |
Below 1 V | ||
| H23-36 (PRE) - H23-27 (GND) | Air conditioner pressure sensor signal | ·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Normal pressure (less than 3.025 MPaG [30.8 kgf/cm2, 439 psi]) and 0.176 MPaG [1.8 kgf/cm2, 26 psi] or higher) |
Less than 4.73 V and 0.62 V or higher*1 |
·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (3.025 MPaG [30.8 kgf/cm2, 439 psi] or higher) |
4.73 V or higher*1 | ||
·
Ignition switch ON ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (less than 0.176 MPaG [1.8 kgf/cm2, 26 psi]) |
Less than 0.62 V*1 |
*1: While sensor voltage is 5 V.
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | H23-20 (SOL+) - H23-27 (GND) |
| Tool Setting | 5 V/DIV., 500 μs./DIV. |
| Condition | ·
Engine running ·
Blower switch: On ·
A/C switch: On |