If cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
| Symptom | Factor |
|---|---|
·
No warm air comes out (Blower control is normal) ·
Outlet air temperature does not increase (Blower control is normal) |
·
Flow shutting valve ·
Engine coolant temperature (low) ·
Blockage in heater radiator unit sub-assembly ·
Heater radiator unit sub-assembly malfunction |
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
| Tester Display |
|---|
| Coolant Temperature |
After warming up the engine, the temperature value displayed is within the range specified in the normal condition column.