DATA LIST
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Rear Defogger Input Signal | Window defogger switch signal input condition | ON or OFF | ON: Window defogger switch is on
OFF: Window defogger switch is off |
- |
| Rear Defogger Output Signal | Window defogger output condition | ON or OFF | ON: Window defogger operates
OFF: Window defogger does not operate |
- |
| Rear Defogger Output Current | Window defogger current | Min.: 0, Max.: 255 A | Approximately 27 A | Window defogger current when output is on |
| Rear Defogger Fuse Shut Off Status | Window defogger fuse condition | ON or OFF | ON: Fuse not shut off
OFF: Fuse shut off |
- |
| Rear Defogger Fuse Shut Off Count | Window defogger fuse shut off times | Min.: 0,
Max.: 255 Times |
0 Times | - |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Rear Defogger Relay | Window defogger operation condition | ON or OFF | ON: Window defogger operates
OFF: Window defogger does not operate |
for Automatic Air Conditioning System |
ACTIVE TEST (for Automatic Air Conditioning System)
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Rear Defogger Relay | Rear window defogger wire (Back door glass) | OFF or ON | - |