Home › General › SPECIFICATIONS › M15A-FKS COOLING
RM36W0E _V1 General _087262 SPECIFICATIONS _0421805 M15A-FKS COOLING F

SPECIFICATIONS  M15A-FKS COOLING  SERVICE DATA  


Thermostat
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard Valve Lift 8.0 mm (0.315 in.) or more at 95°C (203°F)
e3-1(ETM+) - e3-2(ETM-) 11.7 to 14.3 Ω (Always)

Cooling fan motor
Condition Specified Condition
Auxiliary battery voltage applied at 20°C (68°F) 7.4 to 10.9 A

Radiator
Item Condition Specified Condition
Radiator cap sub-assembly Standard pressure
(for brand-new reserve tank cap)
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13 to 18 psi)
Minimum pressure
(for used reserve tank cap)
79 kPa (0.8 kgf/cm2, 11 psi)

Relay
Tester Connection Condition Specified Condition
3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω