Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › ULTRASONIC SENSOR (for Front)
RM36W0E _56 Audio / Visual / Telematics _088657 PARK ASSIST / MONITORING _0422050 ULTRASONIC SENSOR(for Front) G

PARK ASSIST / MONITORING  ULTRASONIC SENSOR(for Front)  INSPECTION  


PROCEDURE

Hide 89341K 1.INSPECT FRONT CORNER ULTRASONIC SENSOR (for LH Side)

a.

Check the resistance.

i.
E436585C10
1.688,0.083 2.083,0.333 0.396,0.25 2.01,0.99 2.313,0.521 true 1.667,0.99 1.458,0.375 true 1.385,1.01 0.938,0.573 true 1.073,1.75 1.385,1.333 true 1.583,1.771 1.646,1.333 true 2.281,1.729 2,1.333 true 0.104,0.135 0.417,0.292 0.313,0.156 10 false *a 0.688,0.49 1,0.688 0.313,0.198 10 false EO 1.219,0.281 1.531,0.479 0.313,0.198 10 false SO 2.354,0.417 2.667,0.615 0.313,0.198 10 false BO 0.979,1.771 1.292,1.969 0.313,0.198 10 false EI 2.24,1.74 2.552,1.938 0.313,0.198 10 false BI 1.51,1.802 1.823,2 0.313,0.198 10 false SI 1.792,0.125 2.104,0.323 0.313,0.198 10 false B1
*a Component without harness connected (Front Corner Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B1-4 (BI) - B1-6 (EI) Always 10 kΩ or higher
B1-4 (BI) - B1-1 (BO) Always Below 1 Ω
B1-5 (SI) - B1-2 (SO) Always Below 15 Ω
B1-6 (EI) - B1-3 (EO) Always Below 1 Ω


If the result is not as specified, replace the front corner ultrasonic sensor.



Hide 89341K 2.INSPECT FRONT CORNER ULTRASONIC SENSOR (for RH Side)

a.

Check the resistance.

i.
E436585C11
1.708,0.073 2.083,0.323 0.375,0.25 2.01,0.99 2.313,0.521 true 1.635,0.979 1.406,0.375 true 1.396,1.01 0.948,0.573 true 1.125,1.74 1.385,1.333 true 1.604,1.771 1.667,1.333 true 2.292,1.719 2.01,1.323 true 0.104,0.135 0.417,0.292 0.313,0.156 10 false *a 0.708,0.479 1.021,0.677 0.313,0.198 10 false EO 1.177,0.292 1.49,0.49 0.313,0.198 10 false SO 2.344,0.396 2.656,0.594 0.313,0.198 10 false BO 1.042,1.75 1.354,1.948 0.313,0.198 10 false EI 2.26,1.74 2.573,1.938 0.313,0.198 10 false BI 1.51,1.781 1.823,1.979 0.313,0.198 10 false SI 1.802,0.115 2.115,0.313 0.313,0.198 10 false B4
*a Component without harness connected (Front Corner Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B4-4 (BI) - B4-6 (EI) Always 10 kΩ or higher
B4-4 (BI) - B4-1 (BO) Always Below 1 Ω
B4-5 (SI) - B4-2 (SO) Always Below 15 Ω
B4-6 (EI) - B4-3 (EO) Always Below 1 Ω


If the result is not as specified, replace the front corner ultrasonic sensor.



Hide 89341L 3.INSPECT FRONT CENTER ULTRASONIC SENSOR (for LH Side)

a.

Check the resistance.

i.
E436585C12
1.698,0.094 2.104,0.323 0.406,0.229 1.917,0.979 2.219,0.51 true 1.635,0.99 1.344,0.333 true 1.396,1 0.948,0.563 true 1.094,1.75 1.406,1.333 true 1.615,1.781 1.677,1.344 true 2.25,1.729 1.969,1.333 true 0.104,0.135 0.417,0.292 0.313,0.156 10 false *a 0.698,0.469 1.01,0.667 0.313,0.198 10 false EO 1.104,0.25 1.417,0.448 0.313,0.198 10 false SO 2.26,0.396 2.573,0.594 0.313,0.198 10 false BO 1,1.771 1.313,1.969 0.313,0.198 10 false EI 2.208,1.76 2.521,1.958 0.313,0.198 10 false BI 1.542,1.813 1.854,2.01 0.313,0.198 10 false SI 1.792,0.135 2.104,0.333 0.313,0.198 10 false B2
*a Component without harness connected (Front Center Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B2-4 (BI) - B2-6 (EI) Always 10 kΩ or higher
B2-4 (BI) - B2-1 (BO) Always Below 1 Ω
B2-5 (SI) - B2-2 (SO) Always Below 15 Ω
B2-6 (EI) - B2-3 (EO) Always Below 1 Ω


If the result is not as specified, replace the front center ultrasonic sensor.



Hide 89341L 4.INSPECT FRONT CENTER ULTRASONIC SENSOR (for RH Side)

a.

Check the resistance.

i.
E436585C13
1.688,0.094 2.073,0.323 0.385,0.229 2.021,0.979 2.323,0.51 true 1.635,0.979 1.354,0.406 true 1.396,0.99 0.948,0.552 true 1.083,1.75 1.396,1.333 true 1.583,1.771 1.646,1.333 true 2.281,1.719 2,1.323 true 0.104,0.135 0.417,0.292 0.313,0.156 10 false *a 0.708,0.458 1.021,0.656 0.313,0.198 10 false EO 1.115,0.313 1.427,0.51 0.313,0.198 10 false SO 2.365,0.396 2.677,0.594 0.313,0.198 10 false BO 0.99,1.76 1.302,1.958 0.313,0.198 10 false EI 2.24,1.74 2.552,1.938 0.313,0.198 10 false BI 1.5,1.781 1.813,1.979 0.313,0.198 10 false SI 1.76,0.135 2.073,0.333 0.313,0.198 10 false B3
*a Component without harness connected (Front Center Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B3-4 (BI) - B3-6 (EI) Always 10 kΩ or higher
B3-4 (BI) - B3-1 (BO) Always Below 1 Ω
B3-5 (SI) - B3-2 (SO) Always Below 15 Ω
B3-6 (EI) - B3-3 (EO) Always Below 1 Ω


If the result is not as specified, replace the front center ultrasonic sensor.