89341K
1.INSPECT FRONT CORNER ULTRASONIC SENSOR (for LH Side)
Check the resistance.
| *a | Component without harness connected (Front Corner Ultrasonic Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B1-4 (BI) - B1-6 (EI) | Always | 10 kΩ or higher |
| B1-4 (BI) - B1-1 (BO) | Always | Below 1 Ω |
| B1-5 (SI) - B1-2 (SO) | Always | Below 15 Ω |
| B1-6 (EI) - B1-3 (EO) | Always | Below 1 Ω |
If the result is not as specified, replace the front corner ultrasonic sensor.
89341K
2.INSPECT FRONT CORNER ULTRASONIC SENSOR (for RH Side)
Check the resistance.
| *a | Component without harness connected (Front Corner Ultrasonic Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B4-4 (BI) - B4-6 (EI) | Always | 10 kΩ or higher |
| B4-4 (BI) - B4-1 (BO) | Always | Below 1 Ω |
| B4-5 (SI) - B4-2 (SO) | Always | Below 15 Ω |
| B4-6 (EI) - B4-3 (EO) | Always | Below 1 Ω |
If the result is not as specified, replace the front corner ultrasonic sensor.
89341L
3.INSPECT FRONT CENTER ULTRASONIC SENSOR (for LH Side)
Check the resistance.
| *a | Component without harness connected (Front Center Ultrasonic Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B2-4 (BI) - B2-6 (EI) | Always | 10 kΩ or higher |
| B2-4 (BI) - B2-1 (BO) | Always | Below 1 Ω |
| B2-5 (SI) - B2-2 (SO) | Always | Below 15 Ω |
| B2-6 (EI) - B2-3 (EO) | Always | Below 1 Ω |
If the result is not as specified, replace the front center ultrasonic sensor.
89341L
4.INSPECT FRONT CENTER ULTRASONIC SENSOR (for RH Side)
Check the resistance.
| *a | Component without harness connected (Front Center Ultrasonic Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B3-4 (BI) - B3-6 (EI) | Always | 10 kΩ or higher |
| B3-4 (BI) - B3-1 (BO) | Always | Below 1 Ω |
| B3-5 (SI) - B3-2 (SO) | Always | Below 15 Ω |
| B3-6 (EI) - B3-3 (EO) | Always | Below 1 Ω |
If the result is not as specified, replace the front center ultrasonic sensor.