Home › Drivetrain › K320 (MULTIDRIVE / CVT) › SHIFT STROKE SENSOR
RM36W0E _52 Drivetrain _087836 K320 MULTIDRIVE / CVT _0422063 SHIFT STROKE SENSOR G

K320 MULTIDRIVE / CVT  SHIFT STROKE SENSOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT SHIFT STROKE SENSOR

a.

Connect 3 new dry-cell batteries (1.5 V each) in series.


b.

Prepare a magnet or equivalent tool.


c.

Connect a positive (+) lead from the batteries to terminal 2 (VDD) and a negative (-) lead to terminal 3 (GND).

C432069C03
2.083,0.917 2.583,1.167 0.5,0.25 5.833,3.083 6.333,2.583 6.333,2.583 6.5,2.583 true 2.25,1.927 2.667,2.26 true 1.51,2.271 1.927,1.938 true 1.521,1.375 1.938,1.708 true 0.552,0.292 0.865,0.448 0.313,0.156 10 false *a 6.313,2.917 6.625,3.073 0.313,0.156 10 false *b 0.531,1.74 0.844,1.896 0.313,0.156 10 false *c 6.542,2.51 6.854,2.667 0.313,0.156 10 false *d 4.75,3.375 4.948,3.552 0.198,0.177 10 false *e 4.917,0.26 5.229,0.417 0.313,0.156 10 false *b 1.198,1.302 1.656,1.5 0.458,0.198 10 false VDD 1.094,2.208 1.552,2.406 0.458,0.198 10 false VOUT 2.708,2.198 3.167,2.396 0.458,0.198 10 false GND 2.208,0.969 2.667,1.167 0.458,0.198 10 false D69
*a Component without harness connected
(Shift Stroke Sensor)
*b Magnet Movement Direction
*c Dry Cell Battery *d Magnet
*e 2.6 mm (0.102 in.) or less - -



d.

Wave the magnet left and right 2.6 mm (0.102 in.) or less from the tip of the shift stroke sensor to output a high/low signal while measuring the voltage.


e.

Measure the voltage according to the value(s) in the table below.

Standard Voltage (Combined Dry-cell Battery Voltage of 4.5 V):
Tester Connection Condition Specified Condition
D69-4 (VOUT) - D69-3 (GND) High voltage 4.09 to 4.19 V
D69-4 (VOUT) - D69-3 (GND) Low voltage 0.36 to 0.45 V


Reference Voltage (Combined Dry-cell Battery Voltage of 5.0 V):
Tester Connection Condition Specified Condition
D69-4 (VOUT) - D69-3 (GND) High voltage 4.55 to 4.65 V
D69-4 (VOUT) - D69-3 (GND) Low voltage 0.4 to 0.5 V