Home › Drivetrain › K320 (MULTIDRIVE / CVT) › PARK / NEUTRAL POSITION SWITCH
RM36W0E _52 Drivetrain _087836 K320 MULTIDRIVE / CVT _0422064 PARK / NEUTRAL POSITION SWITCH G

K320 MULTIDRIVE / CVT  PARK / NEUTRAL POSITION SWITCH  INSPECTION  


PROCEDURE

Hide 84540 1.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY

a.
C193931C62
1.417,0.083 1.917,0.333 0.5,0.25 2.25,0.25 2.083,0.25 2.083,0.25 1.625,0.938 true 2.583,0.5 2.333,0.5 2.333,0.5 2.042,1 true 2.167,2 1.917,2 1.917,2 1.792,1.479 true 0.833,1.833 1.083,1.833 1.083,1.833 1.24,1.469 true 2.583,1.917 2.417,1.917 2.417,1.917 2.135,1.49 true 0.75,0.417 0.917,0.417 0.917,0.417 1.156,0.917 true 2.833,1.75 2.667,1.75 2.667,1.75 2.333,1.49 true 1,0.25 1.167,0.25 1.167,0.25 1.323,0.917 true 2.313,0.188 2.677,0.427 0.365,0.24 10 false RB 2.635,0.406 2.958,0.604 0.323,0.198 10 false RL 0.635,1.75 1.104,1.938 0.469,0.188 10 false NL 2.219,1.927 2.74,2.094 0.521,0.167 10 false DL 0.104,0.073 0.281,0.271 0.177,0.198 10 false *a 2.646,1.833 3.167,2 0.521,0.167 10 false PL 0.615,0.354 1.083,0.542 0.469,0.188 10 false B 2.885,1.677 3.021,1.844 0.135,0.167 10 false L 1.552,0.135 1.917,0.375 0.365,0.24 10 false D45 0.844,0.198 1.167,0.396 0.323,0.198 10 false 2L
*a Component without harness connected
(Park/Neutral Position Switch Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D45-4 (B) - D45-5 (L) Shift lever in P or N Below 1 Ω
D45-4 (B) - D45-5 (L) Shift lever not in P and N 10 kΩ or higher
D45-2 (RB) - D45-6 (PL) Shift lever in P Below 1 Ω
D45-2 (RB) - D45-6 (PL) Shift lever not in P 10 kΩ or higher
D45-2 (RB) - D45-1 (RL) Shift lever in R Below 1 Ω
D45-2 (RB) - D45-1 (RL) Shift lever not in R 10 kΩ or higher
D45-2 (RB) - D45-9 (NL) Shift lever in N Below 1 Ω
D45-2 (RB) - D45-9 (NL) Shift lever not in N 10 kΩ or higher
D45-2 (RB) - D45-7 (DL) Shift lever in D, M, "+" or "-" Below 1 Ω
D45-2 (RB) - D45-7 (DL) Shift lever not in D, M, "+" or "-" 10 kΩ or higher
D45-2 (RB) - D45-3 (2L) Shift lever in B Below 1 Ω
D45-2 (RB) - D45-3 (2L) Shift lever not in B 10 kΩ or higher


If the result is not as specified, replace the park/neutral position switch assembly.