Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PRESSURE SENSOR
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0424508 AIR CONDITIONING PRESSURE SENSOR G

HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88719A 1.INSPECT AIR CONDITIONING PRESSURE SENSOR (for Automatic Air Conditioning System)

a.

Check the wire harness.

i.

Disconnect the A51 air conditioner pressure sensor connector.


ii.

Disconnect the H25 air conditioning amplifier assembly connector.


iii.
E399448C06
1.469,0.115 1.979,0.365 0.51,0.25 1.583,1.25 2,1.417 0.417,0.167 1.438,1.615 1.948,1.865 0.51,0.25 0.917,1.177 1.458,1.01 true 2.344,1.333 1.802,1.021 true 1.979,1.01 2.563,1.177 true 0.594,2.365 1.406,2.542 true 2.833,2.344 2.156,2.531 true 0.615,3.188 1.198,2.833 true 0.427,0.25 0.74,0.406 0.313,0.156 10 false *a 0.427,1.51 0.74,1.667 0.313,0.156 10 false *b 1.594,0.156 2.052,0.354 0.458,0.198 10 false A51 1.573,1.656 1.917,1.823 0.344,0.167 10 false H25 0.802,1.125 0.958,1.323 0.156,0.198 10 false - 2.615,1.115 2.771,1.313 0.156,0.198 10 false + 2.375,1.344 2.688,1.542 0.313,0.198 10 false PR 0.281,3.188 0.729,3.385 0.448,0.198 10 false SG-4 0.25,2.25 0.708,2.448 0.458,0.198 10 false PRE 2.917,2.25 3.365,2.417 0.448,0.167 10 false S5-3
*a Component without harness connected
(Air Conditioner Pressure Sensor)
*b Component without harness connected
(Air Conditioning Amplifier Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A51-1 (-) - H25-15 (SG-4) Always Below 1 Ω
A51-2 (PR) - H25-6 (PRE) Always Below 1 Ω
A51-3 (+) - H25-11 (S5-3) Always Below 1 Ω
A51-1 (-) - Body ground Always 10 kΩ or higher
H25-15 (SG-4) - Body ground Always 10 kΩ or higher
A51-2 (PR) - Body ground Always 10 kΩ or higher
H25-6 (PRE) - Body ground Always 10 kΩ or higher
A51-3 (+) - Body ground Always 10 kΩ or higher
H25-11 (S5-3) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.


iv.

Reconnect the H25 air conditioning amplifier assembly connector.


v.

Turn the ignition switch on (IG).


vi.
E399449C05
1.479,0.188 1.979,0.448 0.5,0.26 2.396,1.896 1.99,1.458 true 0.521,0.26 0.833,0.417 0.313,0.156 10 false *a 1.604,0.229 1.979,0.448 0.375,0.219 10 false A51 2.438,1.885 2.594,2.083 0.156,0.198 10 false +
*a Component without harness connected
(Air Conditioner Pressure Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A51-3 (+) - Body ground IG ON 4.75 to 5.25 V


If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.



b.

Check the air conditioner pressure sensor.

i.

Connect the connector to the A51 air conditioner pressure sensor connector.


ii.

Install a manifold gauge set.


iii.

Turn the A/C switch on.


iv.

Measure the voltage according to the value(s) in the table below.

E399450C06
2.083,0.323 2.583,0.573 0.5,0.25 2.51,1.417 1.188,0.833 true 2.646,1.646 1.229,1.885 true 0.521,0.26 0.833,0.417 0.313,0.156 10 false *a 2.208,0.354 2.667,0.552 0.458,0.198 10 false H25 0.854,0.75 1.313,0.948 0.458,0.198 10 false PRE 0.865,1.813 1.323,2.021 0.458,0.208 10 false SG-4
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Standard Voltage:
Tester Connection Condition Specified Condition
H25-6 (PRE) - H25-15 (SG-4) Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) 0.74 to 4.61 V


HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


If the voltage is not as specified, replace the air conditioner pressure sensor.



Hide 88719A 2.INSPECT AIR CONDITIONING PRESSURE SENSOR (for Manual Air Conditioning System)

a.

Check the wire harness.

i.

Disconnect the A51 air conditioner pressure sensor connector.


ii.

Disconnect the H23 air conditioning amplifier assembly connector.


iii.

Measure the resistance according to the value(s) in the table below.

I116167C03
3.344,0.031 3.854,0.281 0.51,0.25 3.323,1.188 3.833,1.438 0.51,0.25 3.792,0.698 4.25,0.583 true 3.365,0.708 2.969,0.583 true 4.094,1.813 4.667,1.083 true 4.25,2.042 4.25,2.458 true 4.219,1.802 4.698,1.313 true 3.635,0.688 4.125,0.323 true 4.323,0.521 4.479,0.719 0.156,0.198 10 false + 2.823,0.469 2.979,0.667 0.156,0.198 10 false - 2.417,0.083 2.76,0.292 0.344,0.208 10 false *a 3.479,0.073 3.823,0.281 0.344,0.208 10 false A51 3.448,1.229 3.792,1.438 0.344,0.208 10 false H23 1.865,1.323 2.208,1.531 0.344,0.208 10 false *b 4.698,1.01 5.188,1.26 0.49,0.25 10 false S5-3 4.083,2.5 4.583,2.667 0.5,0.167 10 false PRE 4.75,1.229 5.24,1.479 0.49,0.25 10 false SG-4 4.177,0.219 4.667,0.469 0.49,0.25 10 false PR
*a Component without harness connected
(Air Conditioner Pressure Sensor)
*b Component without harness connected
(Air Conditioning Amplifier Assembly)


Standard Resistance:
Tester Connection Condition Specified Condition
A51-1 (-) - H23-12 (SG-4) Always Below 1 Ω
A51-2 (PR) - H23-36 (PRE) Always Below 1 Ω
A51-3 (+) - H23-11 (S5-3) Always Below 1 Ω
A51-1 (-) - Body ground Always 10 kΩ or higher
H23-12 (SG-4) - Body ground Always 10 kΩ or higher
A51-2 (PR) - Body ground Always 10 kΩ or higher
H23-36 (PRE) - Body ground Always 10 kΩ or higher
A51-3 (+) - Body ground Always 10 kΩ or higher
H23-11 (S5-3) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.


iv.

Connect the H23 air conditioning amplifier assembly connector.


v.

Turn the ignition switch on (IG).


vi.
E399449C05
1.479,0.188 1.979,0.448 0.5,0.26 2.396,1.896 1.99,1.458 true 0.521,0.26 0.833,0.417 0.313,0.156 10 false *a 1.604,0.229 1.979,0.448 0.375,0.219 10 false A51 2.438,1.885 2.594,2.083 0.156,0.198 10 false +
*a Component without harness connected
(Air Conditioner Pressure Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A51-3(+) - Body ground IG ON 4.75 to 5.25 V




b.

Check the air conditioner pressure sensor.

i.

Connect the A51 air conditioner pressure sensor connector.


ii.

Install a manifold gauge set.


iii.

Turn the A/C switch on.


iv.

Measure the voltage according to the value(s) in the table below.

I116168C02
3.333,0.333 3.833,0.583 0.5,0.25 2.135,0.833 2.938,1.281 true 2.156,1.979 2.865,1.51 true 0.521,0.26 0.833,0.417 0.313,0.156 10 false *a 3.458,0.375 3.917,0.573 0.458,0.198 10 false H23 1.844,1.938 2.302,2.135 0.458,0.198 10 false PRE 1.76,0.729 2.219,0.938 0.458,0.208 10 false SG-4
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Standard Voltage:
Tester Connection Condition Specified Condition
H23-36 (PRE) - H23-12 (SG-4) Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) 0.74 to 4.61 V


HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


If the voltage is not as specified, replace the air conditioner pressure sensor.