88719A
1.INSPECT AIR CONDITIONING PRESSURE SENSOR (for Automatic Air Conditioning System)
Check the wire harness.
Disconnect the A51 air conditioner pressure sensor connector.
Disconnect the H25 air conditioning amplifier assembly connector.
| *a | Component without harness connected
(Air Conditioner Pressure Sensor) |
| *b | Component without harness connected
(Air Conditioning Amplifier Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-1 (-) - H25-15 (SG-4) | Always | Below 1 Ω |
| A51-2 (PR) - H25-6 (PRE) | Always | Below 1 Ω |
| A51-3 (+) - H25-11 (S5-3) | Always | Below 1 Ω |
| A51-1 (-) - Body ground | Always | 10 kΩ or higher |
| H25-15 (SG-4) - Body ground | Always | 10 kΩ or higher |
| A51-2 (PR) - Body ground | Always | 10 kΩ or higher |
| H25-6 (PRE) - Body ground | Always | 10 kΩ or higher |
| A51-3 (+) - Body ground | Always | 10 kΩ or higher |
| H25-11 (S5-3) - Body ground | Always | 10 kΩ or higher |
If the resistance is not as specified, repair the wire harness.
Reconnect the H25 air conditioning amplifier assembly connector.
Turn the ignition switch on (IG).
| *a | Component without harness connected
(Air Conditioner Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-3 (+) - Body ground | IG ON | 4.75 to 5.25 V |
If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.
Check the air conditioner pressure sensor.
Connect the connector to the A51 air conditioner pressure sensor connector.
Install a manifold gauge set.
Turn the A/C switch on.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H25-6 (PRE) - H25-15 (SG-4) | Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) | 0.74 to 4.61 V |
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
If the voltage is not as specified, replace the air conditioner pressure sensor.
88719A
2.INSPECT AIR CONDITIONING PRESSURE SENSOR (for Manual Air Conditioning System)
Check the wire harness.
Disconnect the A51 air conditioner pressure sensor connector.
Disconnect the H23 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Air Conditioner Pressure Sensor) |
*b | Component without harness connected
(Air Conditioning Amplifier Assembly) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-1 (-) - H23-12 (SG-4) | Always | Below 1 Ω |
| A51-2 (PR) - H23-36 (PRE) | Always | Below 1 Ω |
| A51-3 (+) - H23-11 (S5-3) | Always | Below 1 Ω |
| A51-1 (-) - Body ground | Always | 10 kΩ or higher |
| H23-12 (SG-4) - Body ground | Always | 10 kΩ or higher |
| A51-2 (PR) - Body ground | Always | 10 kΩ or higher |
| H23-36 (PRE) - Body ground | Always | 10 kΩ or higher |
| A51-3 (+) - Body ground | Always | 10 kΩ or higher |
| H23-11 (S5-3) - Body ground | Always | 10 kΩ or higher |
If the resistance is not as specified, repair the wire harness.
Connect the H23 air conditioning amplifier assembly connector.
Turn the ignition switch on (IG).
| *a | Component without harness connected
(Air Conditioner Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-3(+) - Body ground | IG ON | 4.75 to 5.25 V |
Check the air conditioner pressure sensor.
Connect the A51 air conditioner pressure sensor connector.
Install a manifold gauge set.
Turn the A/C switch on.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H23-36 (PRE) - H23-12 (SG-4) | Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) | 0.74 to 4.61 V |
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
If the voltage is not as specified, replace the air conditioner pressure sensor.