RM36W0E
_V1
General
_087262
SPECIFICATIONS
_0424519
WIPER / WASHER
F
SPECIFICATIONS WIPER / WASHER SERVICE DATA
Front Wiper Switch
| Tester Connection
|
Condition
|
Specified Condition
|
| z5-11 (MIST) -z5-4 (E)
|
MIST position
|
Below 1 Ω
|
| z5-11 (MIST) -z5-4 (E)
|
Except MIST position
|
10 kΩ or higher
|
| z5-15 (W_OFF) - z5-4 (E)
|
OFF position
|
Below 1 Ω
|
| z5-15 (W_OFF) - z5-4 (E)
|
Except OFF position
|
10 kΩ or higher
|
| z5-12 (+S) - z5-4 (E)
|
INT position
|
Below 1 Ω
|
| z5-12 (+S) - z5-4 (E)
|
Except INT position
|
10 kΩ or higher
|
| z5-14 (+1) - z5-4 (E)
|
LO position
|
Below 1 Ω
|
| z5-14 (+1) - z5-4 (E)
|
Except LO position
|
10 kΩ or higher
|
| z5-13 (+2) - z5-4 (E)
|
HI position
|
Below 1 Ω
|
| z5-13 (+2) - z5-4 (E)
|
Except HI position
|
10 kΩ or higher
|
Front Washer Switch
| Tester Connection
|
Condition
|
Specified Condition
|
| z5-10 (WF) - z5-4 (E)
|
ON position
|
Below 1 Ω
|
| z5-10 (WF) - z5-4 (E)
|
OFF position
|
10 kΩ or higher
|
Rear Wiper Switch
| Tester Connection
|
Condition
|
Specified Condition
|
| z5-2 (C1R) - z5-4 (E)
|
OFF position
|
10 kΩ or higher
|
| z5-3 (+1R) - z5-4 (E)
|
OFF position
|
10 kΩ or higher
|
| z5-2 (C1R) - z5-4 (E)
|
INT position
|
Below 1 Ω
|
| z5-3 (+1R) - z5-4 (E)
|
ON position
|
Below 1 Ω
|
Rear Washer Switch
| Tester Connection
|
Condition
|
Specified Condition
|
| z5-16 (WR) - z5-4 (E)
|
ON position
|
Below 1 Ω
|
| z5-16 (WR) - z5-4 (E)
|
OFF position
|
10 kΩ or higher
|
WINDSHIELD WIPER RELAY
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 5
|
Auxiliary battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Auxiliary battery voltage applied between terminals 1 and 2
|
Below 1 Ω
|