Home › General › SPECIFICATIONS › WIPER / WASHER
RM36W0E _V1 General _087262 SPECIFICATIONS _0424519 WIPER / WASHER F

SPECIFICATIONS  WIPER / WASHER  SERVICE DATA  


Front Wiper Switch
Tester Connection Condition Specified Condition
z5-11 (MIST) -z5-4 (E) MIST position Below 1 Ω
z5-11 (MIST) -z5-4 (E) Except MIST position 10 kΩ or higher
z5-15 (W_OFF) - z5-4 (E) OFF position Below 1 Ω
z5-15 (W_OFF) - z5-4 (E) Except OFF position 10 kΩ or higher
z5-12 (+S) - z5-4 (E) INT position Below 1 Ω
z5-12 (+S) - z5-4 (E) Except INT position 10 kΩ or higher
z5-14 (+1) - z5-4 (E) LO position Below 1 Ω
z5-14 (+1) - z5-4 (E) Except LO position 10 kΩ or higher
z5-13 (+2) - z5-4 (E) HI position Below 1 Ω
z5-13 (+2) - z5-4 (E) Except HI position 10 kΩ or higher

Front Washer Switch
Tester Connection Condition Specified Condition
z5-10 (WF) - z5-4 (E) ON position Below 1 Ω
z5-10 (WF) - z5-4 (E) OFF position 10 kΩ or higher

Rear Wiper Switch
Tester Connection Condition Specified Condition
z5-2 (C1R) - z5-4 (E) OFF position 10 kΩ or higher
z5-3 (+1R) - z5-4 (E) OFF position 10 kΩ or higher
z5-2 (C1R) - z5-4 (E) INT position Below 1 Ω
z5-3 (+1R) - z5-4 (E) ON position Below 1 Ω

Rear Washer Switch
Tester Connection Condition Specified Condition
z5-16 (WR) - z5-4 (E) ON position Below 1 Ω
z5-16 (WR) - z5-4 (E) OFF position 10 kΩ or higher

WINDSHIELD WIPER RELAY
Tester Connection Condition Specified Condition
3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω