Home › General › SPECIFICATIONS › HYBRID / BATTERY CONTROL
RM36W0E _V1 General _087262 SPECIFICATIONS _0424603 HYBRID / BATTERY CONTROL F

SPECIFICATIONS  HYBRID / BATTERY CONTROL  SERVICE DATA  


Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard Value (for Brand-new Cap) 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)
Minimum Standard Value (for Used Cap) 94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
Item Tester Connection Specified Condition
IGCT-MAIN relay
Resistance
3 - 5 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2)
Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2)

HV Battery Junction Block Assembly
SMRB
Resistance
a1-1 (CBI) - z10-1 (+) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M37-1 (SMRB) and M37-3 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals M37-1 (SMRB) and M37-3 (GND)
O70-1 (SMRB) - O70-3 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRG
Resistance
a2-1 (CEI) - z9-1 (-) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M37-4 (SMRG) and M37-3 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals M37-4 (SMRG) and M37-3 (GND)
O70-4 (SMRG) - O70-3 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRP
Resistance
a2-1 (CEI) - z9-1 (-) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M37-2 (SMRP) and M37-3 (GND)
24.3 to 29.7 Ω
Auxiliary battery voltage applied between terminals M37-2 (SMRP) and M37-3 (GND)
O70-2 (SMRP) - O70-3 (GND) 140 to 290 Ω at -40 to 80°C (-40 to 176°F)

Pattern Select Switch Assembly
Pattern Select Switch Assembly
Resistance
H18-6(S) - H18-5(E) Below 50 Ω
(EV mode switch (pattern select switch assembly) being pushed and held)
10 kΩ or higher
(EV mode switch (pattern select switch assembly) not pushed)
H18-8(DRV) - H18-5(E) Below 50 Ω
(DRIVE mode switch (pattern select switch assembly) being pushed and held)
10 kΩ or higher
(DRIVE mode switch (pattern select switch assembly) not pushed)
Auxiliary Battery positive (+) - H18-4 (ILL+)
Auxiliary Battery negative (-) - H18-1 (ILL-)
Illuminates

Service Plug Grip
Service plug grip - Below 1 Ω

Hybrid Battery Terminal Block
Hybrid Battery Terminal Block - Below 1 Ω

Electric Vehicle Battery Plug Assembly
Tester Connection Condition Specified Condition
A - C Always Below 1 Ω
B - D Below 1 Ω