CUSTOMIZE AIR CONDITIONING SYSTEM
Customizing with the GTS.
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
The following items can be customized.
Select the setting by referring to the table below.
| Tester Display | Description | Default | Setting | ECU |
|---|---|---|---|---|
| Foot/DEF Automatic Blow Up Function | Function to increase the blower level automatically when the defroster is on | ON | $00:OFF,$01:ON | Air conditioning amplifier assembly |
| Foot/DEF Auto Mode | Function to change the air outlet mode to foot/defroster automatically when AUTO mode is on | ON | $00:OFF,$01:ON | Air conditioning amplifier assembly |
| Air Inlet Change Auto Switch Interlock | Function to change the mode automatically to recirculation air mode when turning the A/C on to cool the cabin quickly | Automatic | $00:Manual,$01:Automatic | Air conditioning amplifier assembly |
| ECO Mode Control | Function to disable the operation of the ECO switch assembly (air conditioning control assembly) when set to OFF*1 | ON | $00:OFF,$01:ON | Air conditioning amplifier assembly |
| Fan Speed Increment Control | Function to set the speed to reach the target blower fan speed when AUTO mode is on | Normal | $01:Short,$00:Normal,$02:Long | Air conditioning amplifier assembly |
| Outside Air Mode Auto Switch Function | Function to automatically change the air inlet to FRESH mode when the ignition switch is off for 60 seconds | ON | $00:OFF,$01:ON | Air conditioning amplifier assembly |
| Noise and Vibration Reduction | Function to change the speed of the compressor when set to ON | OFF | $00:OFF,$01:ON | Air conditioning amplifier assembly |
| Set Temperature Shift | Function to perform control with the shifted temperature versus the displayed temperature | Normal | $05:-2C,$06:-1C,$00:Normal,$01:+1C,$02:+2C | Air conditioning amplifier assembly |
| Refrigerant Shortage Check | Function to cancel the refrigerant shortage check (check performed during normal operation) when set to ON | ON | $00:OFF,$01:ON | Air conditioning amplifier assembly |
*1: Make sure to disable ECO mode control before setting this customize setting to ON.