Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for HV Model) › 2020.03–2020.07
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0420299 AIR CONDITIONING SYSTEM(for HV Model) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Total Distance Traveled Total distance traveled Min.: 0
Max.: 999999
Actual total distance displayed -
Total Distance Traveled - Unit Total distance traveled unit km or mile - -
Room Temperature Sensor Cooler (room temp. sensor) thermistor Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual cabin temperature displayed Cooler (room temp. sensor) thermistor circuit malfunction
Ambient Temperature Sensor Thermistor assembly Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual ambient temperature displayed Thermistor assembly circuit malfunction
Front Left Solar Sensor Automatic light control sensor Min.: 0 W/m^2
Max.: 6553.5 W/m^2
Automatic light control sensor value increases as brightness increases Automatic light control sensor circuit malfunction
Front Right Solar Sensor - - - This item is displayed on the GTS but is not used.
Engine Coolant Temperature Sensor Engine coolant temperature sensor Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual engine coolant temperature displayed
·

SFI system malfunction

·

CAN communication system malfunction


Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual evaporator temperature displayed No. 1 cooler thermistor circuit malfunction
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -32.768 MPaG
Max.: 32.767 MPaG
Actual refrigerant pressure displayed
·

Refrigerant line(gas leak etc.)

·

Air conditioner pressure sensor circuit malfunction


Ambient Temperature Adjustment Value Adjusted ambient temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Adjust ambient temperature displayed Air conditioning amplifier assembly circuit malfunction
Front Right Air Outlet Temperature Driver side target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Driver side target temperature displayed
·

When MAX COLD: -327.68°C (-557.82°F)

·

When MAX HOT: 327.67°C (621.81°F)


Front Left Air Outlet Temperature - - - This item is displayed on the GTS but is not used.
Evaporator Target Temperature Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed No. 1 cooler thermistor circuit malfunction
·

When open circuit: -327.68°C (-557.82°F)

·

When short circuit: 327.67°C (621.81°F)


Front Right Set Temperature Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed Air conditioning control assembly circuit malfunction
Front Left Set Temperature - - - This item is displayed on the GTS but is not used.
Front Left Air Mix Damper Control Servo Motor Target Pulse - - - This item is displayed on the GTS but is not used.
Front Left Air Mix Damper Control Servo Motor Actual Pulse - - - This item is displayed on the GTS but is not used.
Front Right Air Mix Damper Control Servo Motor Target Pulse - - - This item is displayed on the GTS but is not used.
Front Right Air Mix Damper Control Servo Motor Actual Pulse - - - This item is displayed on the GTS but is not used.
Air Inlet Damper Control Servo Motor Target Pulse No. 1 blower damper servo sub-assembly target pulse Min.: 128
Max.: 384
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Air Inlet Damper Control Servo Motor Actual Pulse No. 1 blower damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

Recirculation: 256 (pulse)

·

Fresh: 220 (pulse)


No. 1 blower damper servo sub-assembly circuit malfunction
Front Air Mix Damper Control Servo Motor Target Pulse No. 1 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 384
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction
Front Air Mix Damper Control Servo Motor Actual Pulse No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

MAX COLD: 255 (pulse)

·

MAX HOT: 347 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction
Front Air Outlet Damper Control Servo Motor Target Pulse No. 1 air conditioning radiator damper servo sub-assembly target pulse Min.: 128
Max.: 384
·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT: 297 (pulse)

·

FOOT/DEF 320 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction
Front Air Outlet Damper Control Servo Motor Actual Pulse No. 1 air conditioning radiator damper servo sub-assembly actual pulse Min.: 128
Max.: 384
·

FACE: 256 (pulse)

·

B/L: 267 (pulse)

·

FOOT: 297 (pulse)

·

FOOT/DEF 320 (pulse)


No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction
Compressor Target Speed Compressor target speed Min.: 0 rpm
Max.: 10000 rpm
Compressor target speed displayed Compressor operating
·

Compressor with motor assembly


Compressor Actual Speed Compressor actual speed Min.: 0 rpm
Max.: 10000 rpm
Actual compressor speed displayed Compressor operating
·

Compressor with motor assembly


PTC Request Count - - - This item is displayed on the GTS but is not used.
PTC Actual Driving Count - - - This item is displayed on the GTS but is not used.
Refrigerant Gas Type Refrigerant gas type R134a or Hfo1234yf Refrigerant gas type displayed -
PTC Driving Maximum Level - - - This item is displayed on the GTS but is not used.
Refrigerant High Pressure History Count Refrigerant high pressure history Min.: 0
Max.: 255
Number of times refrigerant high pressure history stored displayed *1
Refrigerant Low Pressure History Count Refrigerant low pressure history Min.: 0
Max.: 255
Number of times refrigerant low pressure history stored displayed *1
Operation Limit Control History Count Operation limit control history Min.: 0
Max.: 255
Number of times operation limit control history stored displayed *2
Air Inlet Change Auto Switch Interlock Air inlet mode Manual or Automatic Customized value displayed -
Foot/DEF Automatic Blow Up Function Foot/defroster auto blower speed increase OFF or ON Customized value displayed -
Foot/DEF Auto Mode Foot/defroster auto mode OFF or ON Customized value displayed -
ECO Mode Control Function to cancel ECO mode when set to ON OFF or ON Customized value displayed -
Fan Speed Increment Control Fan speed increment control Short, Normal or Long Customized value displayed -
Outside Air Mode Auto Switch Function Outside air mode auto switch function OFF or ON Customized value displayed -
Noise and Vibration Reduction Function to change the speed of the compressor when set to ON OFF or ON Customized value displayed -
Ion Generate Control - - - This item is displayed on the GTS but is not used.
Set Temperature Shift Shift set temperature Min.: -2 °C
Max.: 2 °C
Customized value displayed -
Refrigerant Shortage Check Refrigerant shortage check OFF or ON Customized value displayed -
Blower Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower motor with fan sub-assembly circuit malfunction
PTC Heater - - - This item is displayed on the GTS but is not used.
Electrical Fan Electric cooling fan motor status ON or OFF Status of electric cooling fan motor displayed -
Ion Generator Ion generator status ON or OFF Status of ion generator displayed -

*1: Refer to the following procedure to clear the refrigerant pressure history.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY

*2: Refer to the following procedure to clear the A/C operation limit history count.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F)
Max.: 140°C (284°F)
75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

·

If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

·

Check if the engine overheats if the value indicated is higher than 135°C (275°F).





ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Level Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Compressor Target Speed Compressor with motor assembly Min.: 800
Max.: 10000
READY ON
PTC Heater - - This item is displayed on the GTS but is not used.
Electrical Fan Electric cooling fan motor OFF or ON -
Ion Generator - - This item is displayed on the GTS but is not used.
Front Left Air Mix Damper Control Servo Motor - - This item is displayed on the GTS but is not used.
Front Right Air Mix Damper Control Servo Motor - - This item is displayed on the GTS but is not used.
Air Inlet Damper Control Servo Motor No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Front Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Front Air Outlet Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-