If cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
| Symptom | Factor |
|---|---|
·
No warm air comes out (Blower control is normal) ·
Outlet air temperature does not increase (Blower control is normal) |
·
Flow shutting valve malfunction ·
Engine coolant temperature (low) ·
No. 1 air conditioning radiator damper servo sub-assembly malfunction ·
Damper and damper link ·
Warm-up control ·
Blockage in heater radiator unit sub-assembly ·
Heater radiator unit sub-assembly malfunction |
Check for DTCs.
SFI system DTCs are not output.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
| Tester Display |
|---|
| Coolant Temperature |
After warming up the engine, the temperature value displayed is within the range specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Front Air Outlet Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Tester Display |
|---|
| Front Air Mix Damper Control Servo Motor |
| Tester Display |
|---|
| Front Air Outlet Damper Control Servo Motor |
Each damper servo motor operates.
| Proceed to |
|---|
| OK |
| NG |
OK
NG