| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from |
|---|---|---|---|---|
| C052C17 | ABS Pump Motor Control Circuit Voltage Above Threshold | The ABS motor voltage is 18.5 V or more for 0.2 seconds or more. | ·
Wire harness or connector ·
Brake actuator assembly |
Brake |
| C052C1C | ABS Pump Motor Control Circuit Voltage Out of Range | An open or short in the ABS motor circuit is detected for 2 seconds or more. | Brake actuator assembly | Brake |
Refer to DTC C052C12.
After replacing the brake actuator assembly, perform linear solenoid valve offset learning, ABS holding solenoid valve learning, yaw rate and acceleration sensor zero point calibration and system information memorization after performing "Reset Memory".
Inspect the fuses for circuits related to this system before performing the following procedure.
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Disconnect the A38 skid control ECU (brake booster with master cylinder assembly) connector.
Disconnect the A40 brake actuator assembly connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-40 (+BM) - A40-13 (+BM) | Always | Below 1 Ω |
| A38-40 (+BM) or A40-13 (+BM) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A40-1 (MGND) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG