The neutral position switch detects whether the shift lever is in neutral. If the shift lever is moved to neutral for a certain period of time or more, control of vehicle speed by the dynamic radar cruise control system is canceled.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Before replacing the ECM, refer to Service Bulletin.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Neutral Position Switch | Neutral position switch status | ON or OFF | ON: Shift lever in neutral
OFF: Shift lever is in any position other than neutral |
- |
| Tester Display |
|---|
| Neutral Position Switch |
The value of the Data List item changes in accordance with the operation of the shift lever.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D51 ECM connector.
Disconnect the D44 neutral position switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D51-83 (VCNP) - D44-1 (W1) | Always | Below 1 Ω |
| D51-106 (NPSW) - D44-2 (TMN) | Always | Below 1 Ω |
| D51-60 (ENPS) - D44-3 (F+) | Always | Below 1 Ω |
| D51-83 (VCNP) or D44-1 (W1) - Other terminals and body ground | Always | 10 kΩ or higher |
| D51-106 (NPSW) or D44-2 (TMN) - Other terminals and body ground | Always | 10 kΩ or higher |
| D51-60 (ENPS) or D44-3 (F+) - Other terminals and body ground | Always | 10 kΩ or higher |
Connect the D44 neutral position switch connector.
Connect the D51 ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D44 neutral position switch connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D44-1 (W1) - Body ground | Ignition switch ON | 4.5 to 5.5 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D44-1 (W1) - D44-2 (TMN) | Always | 995 to 1005 Ω |
| D44-3 (F+) - Body ground | Always | Below 1 Ω |
Connect the D44 neutral position switch connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG