HEATING / AIR CONDITIONING  AIR CONDITIONING PANEL(for Manual Air Conditioning System)  INSPECTION  


PROCEDURE

Hide 55901D 1.INSPECT NO. 1 HEATER CONTROL SUB-ASSEMBLY

a.

Check the resistance.

i.
I116169C03
1.458,2.688 1.979,2.958 0.521,0.271 1.615,1.073 0.833,0.5 true 1.917,3.479 2.438,3.042 true 1.406,4.042 1.552,3.75 true 2.052,3.552 2.479,3.458 true 1,3.052 1.542,3.479 true 1.01,3.49 1.385,3.542 true 2.042,3.75 2.167,4.042 true 0.677,2.406 0.99,2.604 0.313,0.198 10 false *a 0.677,0.406 0.99,0.604 0.313,0.198 10 false *b 3,1.875 3.313,2.073 0.313,0.198 10 false *c 2.625,2.354 2.938,2.552 0.313,0.198 10 false *d 2.719,2.052 3.031,2.25 0.313,0.198 10 false *e 1.583,2.74 2.042,2.938 0.458,0.198 10 false H56 2.51,2.958 3.125,3.156 0.615,0.198 10 false ERDF 1.094,4.073 1.708,4.271 0.615,0.198 10 false DFLG 2.583,3.385 3.198,3.583 0.615,0.198 10 false ILL- 0.698,2.99 1.313,3.188 0.615,0.198 10 false ILL+ 0.74,3.427 1.354,3.625 0.615,0.198 10 false IG+ 2.177,4.104 2.792,4.302 0.615,0.198 10 false RDEF
*a Component without harness connected
(No. 1 Heater Control Sub-assembly)
*b Window Defogger Switch Indicator
*c Defogger Sensing On Position
*d Knob Dial Stopper
*e 17.74° to 27.74°


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Position Specified Condition
H56-2 (ERDF) - H56-9 (DFLG) Defogger sensing on position Below 1 Ω


If the result is not as specified, replace the No. 1 heater control sub-assembly.



b.

Check the illumination.

i.

Apply auxiliary battery voltage to the No. 1 heater control sub-assembly and check the illumination.

OK:
Measurement Condition Specified Condition
Auxiliary battery positive (+) → H56-4 (ILL+)
Auxiliary battery negative (-) → H56-1 (ILL-)
No. 1 heater control sub-assembly illuminates


If the result is not as specified, replace the No. 1 heater control sub-assembly.



c.

Check the indicator.

i.

Apply auxiliary battery voltage to the connector terminal and check the indicator.

OK:
Measurement Condition Switch Position Specified Condition
Auxiliary battery positive (+) → H56-5 (IG+), H56-6 (RDEF)
Auxiliary battery negative (-) → H56-2 (ERDF)
Window Defogger Switch ON position Indicator illuminates
Auxiliary battery positive (+) → H56-5 (IG+), H56-6 (RDEF)
Auxiliary battery negative (-) → H56-2 (ERDF)
Window Defogger Switch OFF position Indicator does not illuminate


If the result is not as specified, replace the No. 1 heater control sub-assembly.



Hide 55902E 2.INSPECT NO. 2 HEATER CONTROL SUB-ASSEMBLY

a.

Check the resistance.

i.
I115632C02
1.51,2.635 2.01,2.885 0.5,0.25 2.323,3.51 2.74,3.396 true 2.323,3.781 2.656,3.948 true 2.083,3.792 2.24,4.094 true 1.219,3.813 1.042,4.083 true 1.208,3.51 0.688,3.448 true 1.479,3.448 0.854,3.094 true 1.844,3.448 2.573,2.979 true 1.531,1.031 0.656,0.531 true 1.74,0.938 1.323,0.281 true 1.979,0.99 2.708,0.521 true 2.125,1.188 2.906,1.083 true 1.344,1.177 0.563,1.146 true 2.833,3.323 3.146,3.521 0.313,0.198 10 false HI 2.719,3.948 3.031,4.146 0.313,0.198 10 false M2 2.229,4.156 2.604,4.385 0.375,0.229 10 false ILL+ 0.906,4.135 1.281,4.365 0.375,0.229 10 false M1 0.521,3.365 0.896,3.594 0.375,0.229 10 false E 0.542,3.021 1.104,3.25 0.563,0.229 10 false ILL- 2.625,2.917 3.188,3.146 0.563,0.229 10 false LO 0.656,2.479 0.969,2.677 0.313,0.198 10 false *a 1.635,2.677 2.094,2.875 0.458,0.198 10 false H33 0.396,1.073 0.958,1.302 0.563,0.229 10 false *b 0.49,0.438 0.865,0.667 0.375,0.229 10 false *c 1.156,0.188 1.531,0.417 0.375,0.229 10 false *d 2.76,0.396 3.135,0.625 0.375,0.229 10 false *e 2.927,0.99 3.302,1.219 0.375,0.229 10 false *f
*a Component without harness connected
(No. 2 Heater Control Sub-assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Position Specified Condition
H33-3 (LO) - H33-5 (E) Blower switch: OFF 10 kΩ or higher
H33-10 (M1) - H33-5 (E) Blower switch: OFF 10 kΩ or higher
H33-6 (M2) - H33-5 (E) Blower switch: OFF 10 kΩ or higher
H33-1 (HI) - H33-5 (E) Blower switch: OFF 10 kΩ or higher
H33-3 (LO) - H33-5 (E) Blower switch: LO Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: LO - M1 Below 1 Ω
H33-10 (M1) - H33-5 (E) Blower switch: LO - M1 Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: M1 Below 1 Ω
H33-10 (M1) - H33-5 (E) Blower switch: M1 Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: M1 - M2 Below 1 Ω
H33-10 (M1) - H33-5 (E) Blower switch: M1 - M2 Below 1 Ω
H33-6 (M2) - H33-5 (E) Blower switch: M1 - M2 Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: M2 Below 1 Ω
H33-6 (M2) - H33-5 (E) Blower switch: M2 Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: M2 - HI Below 1 Ω
H33-6 (M2) - H33-5 (E) Blower switch: M2 - HI Below 1 Ω
H33-1 (HI) - H33-5 (E) Blower switch: M2 - HI Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: HI Below 1 Ω
H33-1 (HI) - H33-5 (E) Blower switch: HI Below 1 Ω


If the result is not as specified, replace the No. 2 heater control sub-assembly.



b.

Check the illumination.

i.

Apply auxiliary battery voltage to the No. 2 heater control sub-assembly and check the illumination.

OK:
Measurement Condition Specified Condition
Auxiliary battery positive (+) → H33-7 (ILL+)
Auxiliary battery negative (-) → H33-4 (ILL-)
No. 2 Heater control sub-assembly illuminates


If the result is not as specified, replace the No. 2 heater control sub-assembly.



Hide 55903A 3.INSPECT NO. 3 HEATER CONTROL SUB-ASSEMBLY

a.

Check the resistance.

i.
E418297C04
1.469,2.021 1.969,2.271 0.5,0.25 1.792,0.865 2.781,0.865 true 2.042,2.729 2.458,2.594 true 2.052,2.906 2.469,2.969 true 0.969,3.052 1.375,2.906 true 1.719,2.979 1.833,3.25 true 2.083,1.385 2.844,1.385 true 0.542,1.385 1.302,1.385 true 1.875,2.958 2.302,3.188 true 1.583,2.656 1.063,2.563 true 1.875,2.667 2.323,2.229 true 2.802,0.802 3.115,1 0.313,0.198 10 false *b 2.521,2.531 2.979,2.729 0.458,0.198 10 false IG+ 2.385,2.135 3,2.333 0.615,0.198 10 false MAXH 1.875,3.219 2.333,3.417 0.458,0.198 10 false A/C 0.708,2.5 1.167,2.698 0.458,0.198 10 false AIND 2.542,2.917 3.156,3.115 0.615,0.198 10 false ILL+ 0.646,3.021 1.26,3.219 0.615,0.198 10 false ILL- 2.885,1.302 3.198,1.5 0.313,0.198 10 false *c 0.594,2 0.906,2.198 0.313,0.198 10 false *a 0.344,1.292 0.656,1.49 0.313,0.198 10 false *d 2.354,3.156 2.969,3.354 0.615,0.198 10 false MAXC 1.594,2.063 2.052,2.26 0.458,0.198 10 false H26
*a Component without harness connected
(No. 3 Heater Control Sub-assembly)
*b A/C Switch Indicator
*c MAX HOT
*d MAX COLD


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
H26-1 (IG+) - H26-2 (MAXH) Except MAX HOT 10 kΩ or higher
H26-1 (IG+) - H26-2 (MAXH) MAX HOT Below 1 Ω
H26-1 (IG+) - H26-7 (MAXC) Except MAX COLD 10 kΩ or higher
H26-1 (IG+) - H26-7 (MAXC) MAX COLD Below 1 Ω
H26-1 (IG+) - H26-8 (A/C) A/C switch ON position Below 1 Ω
H26-1 (IG+) - H26-8 (A/C) A/C switch OFF position 10 kΩ or higher


If the result is not as specified, replace the No. 3 heater control sub-assembly.



b.

Check the illumination.

i.

Apply auxiliary battery voltage to the No. 3 heater control sub-assembly and check the illumination.

OK:
Measurement Condition Specified Condition
Auxiliary battery positive (+) → H26-6 (ILL+)
Auxiliary battery negative (-) → H26-10 (ILL-)
No. 3 heater control sub-assembly illuminates


If the result is not as specified, replace the No. 3 heater control sub-assembly.



c.

Check the indicator.

i.

Apply auxiliary battery voltage to the connector terminal and check the indicator.

OK:
Measurement Condition Switch Position Specified Condition
Auxiliary battery positive (+) → H26-1 (IG+)
Auxiliary battery negative (-) → H26-4 (AIND)
A/C switch: ON Indicator illuminates
Auxiliary battery positive (+) → H26-1 (IG+)
Auxiliary battery negative (-) → H26-4 (AIND)
A/C switch: OFF Indicator does not illuminate


If the result is not as specified, replace the No. 3 heater control sub-assembly.