55901D
1.INSPECT NO. 1 HEATER CONTROL SUB-ASSEMBLY
Check the resistance.
| *a | Component without harness connected
(No. 1 Heater Control Sub-assembly) |
| *b | Window Defogger Switch Indicator |
| *c | Defogger Sensing On Position |
| *d | Knob Dial Stopper |
| *e | 17.74° to 27.74° |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Position | Specified Condition |
|---|---|---|
| H56-2 (ERDF) - H56-9 (DFLG) | Defogger sensing on position | Below 1 Ω |
If the result is not as specified, replace the No. 1 heater control sub-assembly.
Check the illumination.
Apply auxiliary battery voltage to the No. 1 heater control sub-assembly and check the illumination.
| Measurement Condition | Specified Condition |
|---|---|
| Auxiliary battery positive (+) → H56-4 (ILL+)
Auxiliary battery negative (-) → H56-1 (ILL-) |
No. 1 heater control sub-assembly illuminates |
If the result is not as specified, replace the No. 1 heater control sub-assembly.
Check the indicator.
Apply auxiliary battery voltage to the connector terminal and check the indicator.
| Measurement Condition | Switch Position | Specified Condition |
|---|---|---|
| Auxiliary battery positive (+) → H56-5 (IG+), H56-6 (RDEF)
Auxiliary battery negative (-) → H56-2 (ERDF) |
Window Defogger Switch ON position | Indicator illuminates |
| Auxiliary battery positive (+) → H56-5 (IG+), H56-6 (RDEF)
Auxiliary battery negative (-) → H56-2 (ERDF) |
Window Defogger Switch OFF position | Indicator does not illuminate |
If the result is not as specified, replace the No. 1 heater control sub-assembly.
55902E
2.INSPECT NO. 2 HEATER CONTROL SUB-ASSEMBLY
Check the resistance.
| *a | Component without harness connected
(No. 2 Heater Control Sub-assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Position | Specified Condition |
|---|---|---|
| H33-3 (LO) - H33-5 (E) | Blower switch: OFF | 10 kΩ or higher |
| H33-10 (M1) - H33-5 (E) | Blower switch: OFF | 10 kΩ or higher |
| H33-6 (M2) - H33-5 (E) | Blower switch: OFF | 10 kΩ or higher |
| H33-1 (HI) - H33-5 (E) | Blower switch: OFF | 10 kΩ or higher |
| H33-3 (LO) - H33-5 (E) | Blower switch: LO | Below 1 Ω |
| H33-3 (LO) - H33-5 (E) | Blower switch: LO - M1 | Below 1 Ω |
| H33-10 (M1) - H33-5 (E) | Blower switch: LO - M1 | Below 1 Ω |
| H33-3 (LO) - H33-5 (E) | Blower switch: M1 | Below 1 Ω |
| H33-10 (M1) - H33-5 (E) | Blower switch: M1 | Below 1 Ω |
| H33-3 (LO) - H33-5 (E) | Blower switch: M1 - M2 | Below 1 Ω |
| H33-10 (M1) - H33-5 (E) | Blower switch: M1 - M2 | Below 1 Ω |
| H33-6 (M2) - H33-5 (E) | Blower switch: M1 - M2 | Below 1 Ω |
| H33-3 (LO) - H33-5 (E) | Blower switch: M2 | Below 1 Ω |
| H33-6 (M2) - H33-5 (E) | Blower switch: M2 | Below 1 Ω |
| H33-3 (LO) - H33-5 (E) | Blower switch: M2 - HI | Below 1 Ω |
| H33-6 (M2) - H33-5 (E) | Blower switch: M2 - HI | Below 1 Ω |
| H33-1 (HI) - H33-5 (E) | Blower switch: M2 - HI | Below 1 Ω |
| H33-3 (LO) - H33-5 (E) | Blower switch: HI | Below 1 Ω |
| H33-1 (HI) - H33-5 (E) | Blower switch: HI | Below 1 Ω |
If the result is not as specified, replace the No. 2 heater control sub-assembly.
Check the illumination.
Apply auxiliary battery voltage to the No. 2 heater control sub-assembly and check the illumination.
| Measurement Condition | Specified Condition |
|---|---|
| Auxiliary battery positive (+) → H33-7 (ILL+)
Auxiliary battery negative (-) → H33-4 (ILL-) |
No. 2 Heater control sub-assembly illuminates |
If the result is not as specified, replace the No. 2 heater control sub-assembly.
55903A
3.INSPECT NO. 3 HEATER CONTROL SUB-ASSEMBLY
Check the resistance.
| *a | Component without harness connected
(No. 3 Heater Control Sub-assembly) |
| *b | A/C Switch Indicator |
| *c | MAX HOT |
| *d | MAX COLD |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| H26-1 (IG+) - H26-2 (MAXH) | Except MAX HOT | 10 kΩ or higher |
| H26-1 (IG+) - H26-2 (MAXH) | MAX HOT | Below 1 Ω |
| H26-1 (IG+) - H26-7 (MAXC) | Except MAX COLD | 10 kΩ or higher |
| H26-1 (IG+) - H26-7 (MAXC) | MAX COLD | Below 1 Ω |
| H26-1 (IG+) - H26-8 (A/C) | A/C switch ON position | Below 1 Ω |
| H26-1 (IG+) - H26-8 (A/C) | A/C switch OFF position | 10 kΩ or higher |
If the result is not as specified, replace the No. 3 heater control sub-assembly.
Check the illumination.
Apply auxiliary battery voltage to the No. 3 heater control sub-assembly and check the illumination.
| Measurement Condition | Specified Condition |
|---|---|
| Auxiliary battery positive (+) → H26-6 (ILL+)
Auxiliary battery negative (-) → H26-10 (ILL-) |
No. 3 heater control sub-assembly illuminates |
If the result is not as specified, replace the No. 3 heater control sub-assembly.
Check the indicator.
Apply auxiliary battery voltage to the connector terminal and check the indicator.
| Measurement Condition | Switch Position | Specified Condition |
|---|---|---|
| Auxiliary battery positive (+) → H26-1 (IG+)
Auxiliary battery negative (-) → H26-4 (AIND) |
A/C switch: ON | Indicator illuminates |
| Auxiliary battery positive (+) → H26-1 (IG+)
Auxiliary battery negative (-) → H26-4 (AIND) |
A/C switch: OFF | Indicator does not illuminate |
If the result is not as specified, replace the No. 3 heater control sub-assembly.