Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System) › 2020.07–2020.09
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0420298 AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  P06A014  Compressor Solenoid Circuit Short to Ground or Open  


DESCRIPTION

In this circuit, the compressor receives refrigerant compression demand signals from the air conditioning amplifier assembly.

Based on this signal, the compressor changes the amount of compressor output.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
P06A014 Compressor Solenoid Circuit Short to Ground or Open Diagnosis Condition:

Compressor operating


Malfunction Status:

Open or short in compressor solenoid circuit


Detection Time:

Continuously for 30 seconds or more


·

Compressor with pulley assembly

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Compressor operating ○ ○
Malfunction Open in compressor solenoid circuit ○ -
Short in compressor solenoid circuit - ○
Detection Time Continuously for 30 seconds or more Continuously for 30 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored


WIRING DIAGRAM

E254500E29
4.635,1.99 7.156,2.208 2.521,0.219 10 false Air Conditioning Amplifier Assembly 4.969,0.677 5.24,0.99 0.271,0.313 10 false 18 0.979,1.979 3.26,2.333 2.281,0.354 10 false Compressor with Pulley Assembly 0.99,1.823 1.281,2 0.292,0.177 10 false D56 4.604,1.823 4.896,2 0.292,0.177 10 false H24 5.219,0.781 5.667,1.01 0.448,0.229 10 false SOL+ 2.375,1.302 2.646,1.615 0.271,0.313 10 false 1 2.365,0.667 2.656,0.969 0.292,0.302 10 false 2 1.927,0.781 2.365,1.177 0.438,0.396 10 false SOL+ 1.938,1.417 2.375,1.813 0.438,0.396 10 false SOL-

PROCEDURE

1.READ VALUE USING GTS
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Solenoid Valve Control Current Value Solenoid valve control current Min.: 0 mA
Max.: 1000 mA
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
Body Electrical > Air Conditioner > Data List
Tester Display
Solenoid Valve Control Current Value
50003 450 270
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.CONFIRM MODEL
2.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
for 1KR-FE A
for M15A-FKS B



A

3.INSPECT COMPRESSOR WITH PULLEY ASSEMBLY

B

5.INSPECT COMPRESSOR WITH PULLEY ASSEMBLY
3.INSPECT COMPRESSOR WITH PULLEY ASSEMBLY

Pre-procedure1

a.

Disconnect the D56 compressor with pulley assembly connector.


Procedure1

b.
E270993C09
1.5,0.135 1.927,0.396 0.427,0.26 1.135,1.604 1.417,1.208 true 2.031,1.177 2.427,1.646 true 0.104,0.083 0.417,0.24 0.313,0.156 10 false *a 2.406,1.698 2.875,1.948 0.469,0.25 10 false SOL- 0.844,1.646 1.333,1.875 0.49,0.229 10 false SOL+ 1.594,0.188 2.083,0.417 0.49,0.229 10 false D56
*a Component without harness connected
(Compressor with Pulley Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (SOL-) - 2 (SOL+) Compressor temperature 25°C (77°F) 10.1 to 11.1 Ω



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

4.CHECK HARNESS AND CONNECTOR (COMPRESSOR WITH PULLEY ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY AND BODY GROUND)

NG

REPLACE COMPRESSOR WITH PULLEY ASSEMBLY

4.CHECK HARNESS AND CONNECTOR (COMPRESSOR WITH PULLEY ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY AND BODY GROUND)

Pre-procedure1

a.

Disconnect the H24 air conditioning amplifier assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D56-2 (SOL+) - H24-18 (SOL+) Always Below 1 Ω
D56-1 (SOL-) - Body ground Always Below 1 Ω
D56-2 (SOL+) or H24-18 (SOL+) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT COMPRESSOR WITH PULLEY ASSEMBLY

Pre-procedure1

a.

Disconnect the D56 compressor with pulley assembly connector.


Procedure1

b.
E270993C09
1.5,0.135 1.927,0.396 0.427,0.26 1.135,1.604 1.417,1.208 true 2.031,1.177 2.427,1.646 true 0.104,0.083 0.417,0.24 0.313,0.156 10 false *a 2.406,1.698 2.875,1.948 0.469,0.25 10 false SOL- 0.844,1.646 1.333,1.875 0.49,0.229 10 false SOL+ 1.594,0.188 2.083,0.417 0.49,0.229 10 false D56
*a Component without harness connected
(Compressor with Pulley Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (SOL-) - 2 (SOL+) Compressor temperature 25°C (77°F) 10.1 to 11.1 Ω



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

6.CHECK HARNESS AND CONNECTOR (COMPRESSOR WITH PULLEY ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY AND BODY GROUND)

NG

REPLACE COMPRESSOR WITH PULLEY ASSEMBLY

6.CHECK HARNESS AND CONNECTOR (COMPRESSOR WITH PULLEY ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY AND BODY GROUND)

Pre-procedure1

a.

Disconnect the H24 air conditioning amplifier assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D56-2 (SOL+) - H24-18 (SOL+) Always Below 1 Ω
D56-1 (SOL-) - Body ground Always Below 1 Ω
D56-2 (SOL+) or H24-18 (SOL+) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

c.

None



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR