Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System) › from 2020.07
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0420298 AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  No Cool Air Comes Out  


DESCRIPTION

If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.

Symptom Factor
No cool air comes out
(Blower control is normal)
·

Compressor with pulley assembly malfunction

·

Refrigerant pressure is extremely high or low

·

Refrigerant volume (low)

·

Clogged cooler condenser assembly fins

·

Cooling fan system malfunction

·

Mechanical locking of damper and damper link

·

No. 1 cooler thermistor malfunction

·

Open in air conditioner pressure sensor power source circuit

·

High inlet air temperature



PROCEDURE

1.CHECK SWITCH INDICATOR
a.

Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.

OK:

All switch indicators operate normally.



Result:
Proceed to
OK
NG



OK

2.CONFIRM MODEL

NG

2.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
for Dual Type A
for Single Type B



A

3.PERFORM ACTIVE TEST USING GTS

B

4.PERFORM ACTIVE TEST USING GTS
3.PERFORM ACTIVE TEST USING GTS
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Front Left Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Front Right Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Left Air Mix Damper Control Servo Motor
50004 450 26
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Right Air Mix Damper Control Servo Motor
50004 450 28
OK:

Each damper servo motor operates.



Result:
Result Proceed to
OK (for HFC-134a(R134a)) A
OK (for HFO-1234yf(R1234yf)) B
NG C



A

B

C

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR

4.PERFORM ACTIVE TEST USING GTS
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Front Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Front Air Outlet Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Air Mix Damper Control Servo Motor
50004 450 46
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Air Outlet Damper Control Servo Motor
50004 450 47
OK:

Each damper servo motor operates.



Result:
Result Proceed to
OK (for HFC-134a(R134a)) A
OK (for HFO-1234yf(R1234yf)) B
NG C



A

B

C

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR