DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Total distance traveled | Min.: 0
Max.: 999999 |
Actual total distance displayed | - |
| Total Distance Traveled - Unit | Total distance traveled unit | km or mile | - | - |
| Ambient Temperature Sensor | Thermistor assembly | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual ambient temperature displayed | Thermistor assembly circuit malfunction |
| Engine Coolant Temperature Sensor | Engine coolant temperature sensor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual engine coolant temperature displayed | ·
SFI system malfunction ·
CAN communication system malfunction |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor circuit malfunction |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32.768 MPaG
Max.: 32.767 MPaG |
Actual refrigerant pressure displayed | ·
Refrigerant line(gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Ambient Temperature Adjustment Value | Adjusted ambient temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Adjust ambient temperature displayed | Air conditioning amplifier assembly circuit malfunction |
| Evaporator Target Temperature | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | No. 1 cooler thermistor circuit malfunction
·
When open circuit: -327.68°C (-557.82°F) ·
When short circuit: 327.67°C (621.81°F) |
| Solenoid Valve Control Current Value | Solenoid valve control current | Min.: 0 mA
Max.: 1000 mA |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| PTC Request Count | Number of quick heater assembly elements requested to be driven*1 | Min.: 0
Max.: 3 |
Number of quick heater assembly elements requested to be driven | PTC heater circuit malfunction |
| PTC Actual Driving Count | Number quick heater assembly elements actually driven*1 | Min.: 0
Max.: 3 |
Number quick heater assembly elements actually driven | PTC heater circuit malfunction |
| Refrigerant Gas Type | Refrigerant gas type | R134a or Hfo1234yf | Refrigerant gas type displayed | - |
| PTC Driving Maximum Level | Maximum number of quick heater assembly elements that can be driven*1 | Min.: 0
Max.: 3 |
Maximum number of quick heater assembly elements that can be driven | PTC heater circuit malfunction |
| Refrigerant High Pressure History Count | Refrigerant high pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant high pressure history stored displayed | *2 |
| Refrigerant Low Pressure History Count | Refrigerant low pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant low pressure history stored displayed | *2 |
| Operation Limit Control History Count | Operation limit control history | Min.: 0
Max.: 255 |
Number of times operation limit control history stored displayed | *3 |
| Evaporator Control | Evaporator control | Manual or Automatic | Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check | OFF or ON | Customized value displayed | - |
| PTC Heater | Quick heater assembly drive status*1 | Min.: 0
Max.: 3 |
Quick heater assembly drive status | PTC heater circuit malfunction |
| A/C Driving Demand | A/C control cutoff signal | ON or OFF | The ECM sends the air conditioning control cutoff signal displayed | ECM circuit malfunction |
*1: w/ PTC Heater
*2: Refer to the following procedure to clear the refrigerant pressure history.
*3: Refer to the following procedure to clear the A/C operation limit history count.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F)
Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| PTC Heater No.1 Fuse Shut Off Status | Quick heater assembly (PTC1) fuse condition | OFF or ON | OFF: Fuse shut off
ON: Fuse not shut off |
- |
| PTC Heater No.2 Fuse Shut Off Status | Quick heater assembly (PTC2) fuse condition | OFF or ON | OFF: Fuse shut off
ON: Fuse not shut off |
- |
| PTC Heater No.3 Fuse Shut Off Status | Quick heater assembly (PTC3) fuse condition | OFF or ON | OFF: Fuse shut off
ON: Fuse not shut off |
- |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| PTC Heater | Quick heater assembly*1 | Min.: 0
Max.: 3 |
- |
| A/C Driving Demand | A/C control cutoff signal | OFF or ON | - |
*1: w/ PTC Heater