In this circuit, the compressor receives refrigerant compression demand signals from the air conditioning amplifier assembly.
Based on this signal, the compressor changes the amount of compressor output.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| P06A014 | Compressor Solenoid Circuit Short to Ground or Open | Diagnosis Condition:
Compressor operating Malfunction Status: Open or short in compressor solenoid circuit Detection Time: Continuously for 30 seconds or more |
·
Compressor with pulley assembly ·
Harness or connector ·
Air conditioning amplifier assembly |
Memorized |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Compressor operating | ○ | ○ |
| Malfunction | Open in compressor solenoid circuit | ○ | - |
| Short in compressor solenoid circuit | - | ○ | |
| Detection Time | Continuously for 30 seconds or more | Continuously for 30 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Solenoid Valve Control Current Value | Solenoid valve control current | Min.: 0 mA
Max.: 1000 mA |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| Tester Display |
|---|
| Solenoid Valve Control Current Value |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for 1KR-FE | A |
| for M15A-FKS | B |
A
B
Pre-procedure1
Disconnect the D56 compressor with pulley assembly connector.
Procedure1
| *a | Component without harness connected
(Compressor with Pulley Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (SOL-) - 2 (SOL+) | Compressor temperature 25°C (77°F) | 10.1 to 11.1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the H23 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D56-2 (SOL+) - H23-20 (SOL+) | Always | Below 1 Ω |
| D56-1 (SOL-) - Body ground | Always | Below 1 Ω |
| D56-2 (SOL+) or H23-20 (SOL+) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the D56 compressor with pulley assembly connector.
Procedure1
| *a | Component without harness connected
(Compressor with Pulley Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (SOL-) - 2 (SOL+) | Compressor temperature 25°C (77°F) | 10.1 to 11.1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the H23 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D56-2 (SOL+) - H23-20 (SOL+) | Always | Below 1 Ω |
| D56-1 (SOL-) - Body ground | Always | Below 1 Ω |
| D56-2 (SOL+) or H23-20 (SOL+) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG