DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Total distance traveled | Min.: 0
Max.: 999999 |
Actual total distance displayed | - |
| Total Distance Traveled - Unit | Total distance traveled unit | km or mile | - | - |
| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual cabin temperature displayed | Cooler (room temp. sensor) thermistor circuit malfunction |
| Ambient Temperature Sensor | Thermistor assembly | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual ambient temperature displayed | Thermistor assembly circuit malfunction |
| Front Left Solar Sensor | Automatic light control sensor*1 | Min.: 0 W/m^2
Max.: 6553.5 W/m^2 |
Automatic light control sensor value increases as brightness increases | Automatic light control sensor circuit malfunction |
| Front Right Solar Sensor | Automatic light control sensor*2 | Min.: 0 W/m^2
Max.: 6553.5 W/m^2 |
Automatic light control sensor value increases as brightness increases | Automatic light control sensor circuit malfunction |
| Engine Coolant Temperature Sensor | Engine coolant temperature sensor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual engine coolant temperature displayed | ·
SFI system malfunction ·
CAN communication system malfunction |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor circuit malfunction |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32.768 MPaG
Max.: 32.767 MPaG |
Actual refrigerant pressure displayed | ·
Refrigerant line(gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Ambient Temperature Adjustment Value | Adjusted ambient temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Adjust ambient temperature displayed | Air conditioning amplifier assembly circuit malfunction |
| Front Right Air Outlet Temperature | Passenger side target temperature*2
Driver side target temperature*1 |
Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Passenger side target temperature displayed*2
Driver side target temperature displayed*1 |
·
When MAX COLD: -327.68°C (-557.82°F) ·
When MAX HOT: 327.67°C (621.81°F) |
| Front Left Air Outlet Temperature | Driver side target temperature*2 | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Driver side target temperature displayed | ·
When MAX COLD: -327.68°C (-557.82°F) ·
When MAX HOT: 327.67°C (621.81°F) |
| Evaporator Target Temperature | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | No. 1 cooler thermistor circuit malfunction
·
When open circuit: -327.68°C (-557.82°F) ·
When short circuit: 327.67°C (621.81°F) |
| Front Right Set Temperature | Passenger side set temperature*2
Driver side set temperature*1 |
Min.: MAX COLD
Max.: MAX HOT |
Passenger side set temperature displayed*2
Driver side set temperature displayed*1 |
Air conditioning control assembly circuit malfunction |
| Front Left Set Temperature | Driver side set temperature*2 | Min.: MAX COLD
Max.: MAX HOT |
Driver side set temperature displayed | Air conditioning control assembly circuit malfunction |
| Front Left Air Mix Damper Control Servo Motor Target Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse*3 | Min.: 128
Max.: 384 |
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Left Air Mix Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse*3 | Min.: 128
Max.: 384 |
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right Air Mix Damper Control Servo Motor Target Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse*3 | Min.: 128
Max.: 384 |
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Right Air Mix Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse*3 | Min.: 128
Max.: 384 |
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Control Servo Motor Target Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128
Max.: 384 |
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Control Servo Motor Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128
Max.: 384 |
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Front Air Mix Damper Control Servo Motor Target Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse*4 | Min.: 128
Max.: 384 |
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Air Mix Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly actual pulse*4 | Min.: 128
Max.: 384 |
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Air Outlet Damper Control Servo Motor Target Pulse | No. 1 air conditioning radiator damper servo sub-assembly target pulse | Min.: 128
Max.: 384 |
·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT: 297 (pulse) ·
FOOT/DEF 320 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Front Air Outlet Damper Control Servo Motor Actual Pulse | No. 1 air conditioning radiator damper servo sub-assembly actual pulse | Min.: 128
Max.: 384 |
·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT: 297 (pulse) ·
FOOT/DEF 320 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
| Compressor Target Speed | Compressor target speed | Min.: 0 rpm
Max.: 10000 rpm |
Compressor target speed displayed | Compressor operating
·
Compressor with motor assembly |
| Compressor Actual Speed | Compressor actual speed | Min.: 0 rpm
Max.: 10000 rpm |
Actual compressor speed displayed | Compressor operating
·
Compressor with motor assembly |
| PTC Request Count | Number of quick heater assembly elements requested to be driven*5 | Min.: 0
Max.: 3 |
Number of quick heater assembly elements requested to be driven | PTC heater circuit malfunction |
| PTC Actual Driving Count | Number quick heater assembly elements actually driven*5 | Min.: 0
Max.: 3 |
Number quick heater assembly elements actually driven | PTC heater circuit malfunction |
| Refrigerant Gas Type | Refrigerant gas type | R134a or Hfo1234yf | Refrigerant gas type displayed | - |
| PTC Driving Maximum Level | Maximum number of quick heater assembly elements that can be driven*5 | Min.: 0
Max.: 3 |
Maximum number of quick heater assembly elements that can be driven | PTC heater circuit malfunction |
| Refrigerant High Pressure History Count | Refrigerant high pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant high pressure history stored displayed | *6 |
| Refrigerant Low Pressure History Count | Refrigerant low pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant low pressure history stored displayed | *6 |
| Operation Limit Control History Count | Operation limit control history | Min.: 0
Max.: 255 |
Number of times operation limit control history stored displayed | *7 |
| Efficient Ventilation Mode | Air inlet mode | OFF or ON | Customized value displayed | - |
| Foot/DEF Automatic Blow Up Function | Foot/defroster auto blower speed increase | OFF or ON | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/defroster auto mode | OFF or ON | Customized value displayed | - |
| ECO Mode Control | Function to cancel ECO mode when set to ON | OFF or ON | Customized value displayed | - |
| Fan Speed Increment Control | Fan speed increment control | Short, Normal or Long | Customized value displayed | - |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function | OFF or ON | Customized value displayed | - |
| Noise and Vibration Reduction | Function to change the speed of the compressor when set to ON | OFF or ON | Customized value displayed | - |
| Ion Generate Control | - | - | - | This item is displayed on the GTS but is not used. |
| Set Temperature Shift | Shift set temperature | Min.: -2 °C
Max.: 2 °C |
Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check | OFF or ON | Customized value displayed | - |
| Blower Level | Blower motor speed level | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Blower motor with fan sub-assembly circuit malfunction |
| PTC Heater | Quick heater assembly drive status*5 | Min.: 0
Max.: 3 |
Quick heater assembly drive status | PTC heater circuit malfunction |
| Electrical Fan | Electric cooling fan motor status | OFF or ON | Status of electric cooling fan motor displayed | - |
| Ion Generator | Ion generator status | OFF or ON | Status of ion generator displayed | - |
*1: for RHD
*2: for LHD
*3: for Dual Type
*4: for Single Type
*5: w/ PTC Heater
*6: Refer to the following procedure to clear the refrigerant pressure history.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY
*7: Refer to the following procedure to clear the A/C operation limit history count.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F)
Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| PTC Heater No.1 Fuse Shut Off Status | Quick heater assembly (PTC1) fuse condition | OFF or ON | OFF: Fuse shut off
ON: Fuse not shut off |
- |
| PTC Heater No.2 Fuse Shut Off Status | Quick heater assembly (PTC2) fuse condition | OFF or ON | OFF: Fuse shut off
ON: Fuse not shut off |
- |
| PTC Heater No.3 Fuse Shut Off Status | Quick heater assembly (PTC3) fuse condition | OFF or ON | OFF: Fuse shut off
ON: Fuse not shut off |
- |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Level | Blower motor with fan sub-assembly | Min.: 0
Max.: 31 |
- |
| Compressor Target Speed | Compressor with motor assembly | Min.: 800
Max.: 10000 |
READY ON |
| PTC Heater | Quick heater assembly*1 | Min.: 0
Max.: 3 |
- |
| Electrical Fan | Electric cooling fan motor | OFF or ON | - |
| Ion Generator | - | - | This item is displayed on the GTS but is not used. |
| Front Left Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse*2 | Min.: 128
Max.: 384 |
- |
| Front Right Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse*2 | Min.: 128
Max.: 384 |
- |
| Air Inlet Damper Control Servo Motor | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 384 |
- |
| Front Air Mix Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse*3 | Min.: 128
Max.: 384 |
- |
| Front Air Outlet Damper Control Servo Motor | No. 1 air conditioning radiator damper servo sub-assembly pulse*3 | Min.: 128
Max.: 384 |
- |
*1: w/ PTC Heater
*2: for Dual Type
*3: for Single Type