Home › General › SPECIFICATIONS › STOP AND START › from 2020.07
RM36W0E _V1 General _087262 SPECIFICATIONS _0431199 STOP AND START F

SPECIFICATIONS  STOP AND START  SERVICE DATA  


Eco Run Cancel Switch Assembly
Tester Connection Switch Condition Specified Condition
H18-6 (ECU) - H18-5 (E) Eco run cancel switch assembly (combination switch assembly) being pushed and held Below 50 Ω