Home › Power Source / Network › 1KR-FE (BATTERY / CHARGING) › CHARGING SYSTEM › from 2020.07
RM36W0E _57 Power Source / Network _090846 1KR-FE BATTERY / CHARGING _0430815 CHARGING SYSTEM C

1KR-FE BATTERY / CHARGING  CHARGING SYSTEM  P160200  Deterioration of Battery Low Capacity  


DESCRIPTION

The ECM determines the battery capacity according to the voltage of the BATT terminal while the engine is running (not cranking).

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Memory Note
P160200 Deterioration of Battery Low Capacity Battery capacity is low for 10 seconds or more when the engine is running (not cranking)
(1 trip detection logic)
·

Battery

·

Wire harness or connector


Charge warning light does not come on DTC stored SAE Code: P1602

WIRING DIAGRAM

A470192E01
4.958,0.823 5.188,1.01 0.229,0.188 10 false 15 5.313,0.813 5.927,1.01 0.615,0.198 10 false BATT 5.333,2.333 5.646,2.531 0.313,0.198 10 false E1 5.406,3.188 5.865,3.385 0.458,0.198 10 false ECM 2.771,1.115 4.146,1.313 1.375,0.198 10 false EFI NO.1 0.469,0.938 1.365,1.573 0.896,0.635 10 false from Auxiliary Battery 5.406,3 5.865,3.198 0.458,0.198 10 false A55 5.073,2.177 5.229,2.375 0.156,0.198 10 false 4

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


HINT:

If any DTCs other than P160200 are output, troubleshoot those DTCs first.


PROCEDURE

1.CHECK CHARGING SYSTEM

Result:
Result
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)

NG

REPAIR OR REPLACE CHARGING SYSTEM

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)

Pre-procedure1

a.

Disconnect the A55 ECM connector.


Procedure1

b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A55-1 (BATT) - Body ground Always 11 to 14 V



Post-procedure1

c.

None.


Result:
Result
OK
NG



OK

CHECK FOR INTERMITTENT PROBLEMS

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR