RM36W0E
_V1
General
_087262
SPECIFICATIONS
_0431369
1KR-FE COOLING
F
SPECIFICATIONS 1KR-FE COOLING SERVICE DATA
| Water inlet (Thermostat)
|
Valve opening temperature
|
78 to 82°C (172 to 180°F)
|
| Valve lift
|
8.5 mm (0.33 in.) or more at 93°C (199°F)
|
| Cooling fan motor
|
20°C (68°F)
|
11.2 to 14.4 A
|
| Fan No. 1 relay
|
3 - 5
|
10 kΩ or higher (Battery voltage not applied)
|
| 3 - 5
|
Below 1 Ω(Battery voltage applied to terminals 1 and 2)
|
| Fan No. 2 relay
|
3 - 4
|
Below 1 Ω (Battery voltage not applied)
|
| 3 - 4
|
10 kΩ or higher (Battery voltage applied to terminals 1 and 2)
|
| 3 - 5
|
10 kΩ or higher (Battery voltage not applied)
|
| 3 - 5
|
Below 1 Ω (Battery voltage applied to terminals 1 and 2)
|
| Cooling fan resistor
|
20°C (68°F)
|
1.17 to 1.43 Ω
|
| Radiator cap sub-assembly
|
Standard valve (for brand new cap)
|
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
|
| Minimum standard valve (for using cap)
|
78.5 kPa (0.80 kgf/cm2, 11.38 psi)
|