16331A
1.INSPECT THERMOSTAT
The valve opening temperature is inscribed on the thermostat.
Check the operation.
Immerse the thermostat in water and gradually heat the water.
Make sure not to burn yourself.
Check the valve opening temperature of the thermostat.
78 to 82°C (172 to 180°F)
If the valve opening temperature is not as specified, replace the thermostat.
| *a | Valve Lift |
Check the valve lift.
8.5 mm (0.33 in.) or more at 93°C (199°F)
Check that the valve is fully closed when the thermostat is at low temperatures (below 75°C (167°F)).
If the valve is not fully closed, replace the thermostat.