Home › Engine / Hybrid System › 1KR-FE (ENGINE CONTROL) › HEATED OXYGEN SENSOR (for Sensor 2) › from 2020.07
RM36W0E _51 Engine / Hybrid System _091054 1KR-FE ENGINE CONTROL _0431479 HEATED OXYGEN SENSOR(for Sensor 2) G

1KR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR(for Sensor 2)  INSPECTION  


PROCEDURE

Hide 89465A 1.INSPECT HEATED OXYGEN SENSOR

a.
A189305C07
2.563,1.625 2.302,1.625 2.302,1.625 1.99,1.271 false 0.719,0.281 0.917,0.281 0.917,0.281 1.448,0.729 false 2.615,0.271 2.5,0.271 2.5,0.271 1.958,0.74 false 1.49,0.781 1.708,0.99 0.219,0.208 10 false 2 1.865,0.771 2.052,1.01 0.188,0.24 10 false 1 1.479,1.146 1.656,1.323 0.177,0.177 10 false 4 1.865,1.146 2.042,1.323 0.177,0.177 10 false 3 2.677,0.177 3.146,0.406 0.469,0.229 10 false +B 0.344,0.198 0.854,0.458 0.51,0.26 10 false HT1B 2.625,1.552 2.958,1.792 0.333,0.24 10 false E1 0.052,0.073 0.333,0.396 0.281,0.323 10 false *a
*a Component without harness connected
(Heated Oxygen Sensor (Sensor 2))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (+B) - 2 (HT1B) 20°C (68°F) 2.7 to 3.3 Ω
2 (HT1B) - 3 (E1) Always 10 kΩ or higher


If the result is not as specified, replace the heated oxygen sensor (sensor 2).