RM36W0E
_V1
General
_087262
SPECIFICATIONS
_0424585
M15A-FKS STARTING
F
SPECIFICATIONS M15A-FKS STARTING SERVICE DATA
Starter Assembly (w/ Stop And Start System)
| Tester Connection
|
Condition
|
Specified Condition
|
| Battery positive (+) terminal - Terminal 30 - Terminal 50
|
11.5 V
|
Below 90 A
|
Starter Assembly (w/o Stop And Start System)
| Tester Connection
|
Condition
|
Specified Condition
|
| Battery positive (+) terminal - Terminal 30 - Terminal 50
|
11.5 V
|
Below 90 A
|
Magnet start switch assembly
| Tester Connection
|
Condition
|
Specified Condition
|
| Terminal 50 - Magnet starter switch assembly body
|
Always
|
Below 2 Ω
|
Starter Armature Assembly (w/ Stop And Start System)
| Tester Connection
|
Condition
|
Specified Condition
|
| Segment - Segment
|
Always
|
Below 1 Ω
|
| Segment - Starter armature core
|
10 kΩ or higher
|
| Commutator runout
|
Maximum runout
|
0.05 mm (0.00197 in.)
|
| Commutator diameter
|
Standard diameter
|
29.0 mm (1.1417 in.)
|
| Minimum diameter
|
28.0 mm (1.1024 in.)
|
| Undercut depth
|
Standard undercut depth
|
0.7 mm (0.0276 in.)
|
| Minimum undercut depth
|
0.4 mm (0.0157 in.)
|
Starter Armature Assembly (w/o Stop And Start System)
| Tester Connection
|
Condition
|
Specified Condition
|
| Segment - Segment
|
Always
|
Below 1 Ω
|
| Segment - Starter armature core
|
10 kΩ or higher
|
| Commutator runout
|
Maximum runout
|
0.05 mm (0.00197 in.)
|
| Commutator diameter
|
Standard diameter
|
25.0 mm (0.984 in.)
|
| Minimum diameter
|
24.0 mm (0.945 in.)
|
| Undercut depth
|
Standard undercut depth
|
0.7 mm (0.0276 in.)
|
| Minimum undercut depth
|
0.2 mm (0.00787 in.)
|
Starter Brush Holder Assembly
| Brush length
|
Standard length
|
11.6 mm (0.457 in.)
|
| Minimum length
|
7.6 mm (0.299 in.)
|
Engine Switch
| Tester Connection
|
Condition
|
Specified Condition
|
H68-12(SS1) - H68-3(GND)
H68-6(SS2) - H68-3(GND)
H68-11(SS3) - H68-3(GND)
|
Not pushed
|
10 kΩ or higher
|
| Pushed
|
Below 1 Ω
|
| Tester Connection
|
Condition
|
Specified Condition
|
| H68-5(SWIL) - H68-3(GND)
|
H68-5(SWIL) - Auxiliary battery positive (+)
H68-3(GND) - Auxiliary battery negative (-)
|
Illuminates
|
Ignition or Starter Switch Assembly
| Tester Connection
|
Condition
|
Specified Condition
|
| Between all terminals
|
LOCK
|
10 kΩ or higher
|
| H54-6 (ACC) - H54-7 (AM1)
|
ACC
|
Below 1 Ω
|
| H54-6 (ACC) - H54-7 (AM1) - H54-8 (IG1)
|
ON
|
Below 1 Ω
|
| H54-1 (AM2) - H54-2 (IG2)
|
| H54-5 (ST1) - H54-7 (AM1) - H54-8 (IG1)
|
START
|
Below 1 Ω
|
| H54-1 (AM2) - H54-2 (IG2) - H54-4 (ST2)
|
ST No. 1 Relay
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 5
|
Battery voltage not applied to terminals 1 and 2
|
10 kΩ or higher
|
| Battery voltage applied to terminals 1 and 2
|
Below 1 Ω
|