Home › Power Source / Network › 1KR-FE (BATTERY / CHARGING) › GENERATOR (for 80A Type) › from 2020.07
RM36W0E _57 Power Source / Network _090846 1KR-FE BATTERY / CHARGING _0432212 GENERATOR(for 80A Type) A

1KR-FE BATTERY / CHARGING  GENERATOR(for 80A Type)  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the generator with regulator assembly removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link
Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Parking assist monitor system (Click here)

HINT:

When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

·

Learning completes when vehicle is driven

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Lane tracing assist system Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 seconds or more. (Click here)
Pre-collision system
Stop and start system Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes) (Click here)

·

Learning completes when vehicle is operated normally

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Power door lock control system
·

Back door opener


Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch. (Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized. -



PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY


Hide 2.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL

Hide 27020 4.REMOVE GENERATOR ASSEMBLY

a.
A462841

Remove the terminal cap.


b.
A462842

Remove the nut and disconnect the wire harness from terminal B.


c.

Disconnect the generator assembly connector and disengage the 2 wire harness clamps.


d.

Disconnect the compressor with pulley assembly connector.


e.
A331326

Remove the 3 bolts, generator bracket and generator assembly from the timing chain cover sub-assembly.


f.
A322656

Remove the 2 bolts and 2 wire harness clamp brackets.