Home › Vehicle Interior › HEATING / AIR CONDITIONING › BLOWER UNIT › from 2020.07
RM36W0E _58 Vehicle Interior _088019 HEATING / AIR CONDITIONING _0424497 BLOWER UNIT A

HEATING / AIR CONDITIONING  BLOWER UNIT  REASSEMBLY  


PROCEDURE

Hide 87138C 1.INSTALL BLOWER RESISTOR (for Manual Air Conditioning System)

a.

for Single Layer Type:

i.
I115731

Install the blower resistor with the 2 screws.



b.

for Double Layer Type:

i.
I116463C01
0,0 0,0 false
V113147

Install in this Direction


Install the blower resistor with the screw as shown in the illustration.



Hide 87139C 2.INSTALL CLEAN AIR FILTER

a.
I116464

Install the clean air filter.

NOTICE:

Make sure that the "UP" mark is facing the correct direction before installing the clean air filter.



Hide 88899M 3.INSTALL AIR FILTER COVER PLATE

a.
I116459

Engage the guides and claw to install the air filter cover plate.


Hide 87103B 4.INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY

a.
I116458

Install the blower motor with fan sub-assembly with the 3 screws.


Hide 87130K 5.INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System)

a.
I116457

Install the No. 1 blower damper servo sub-assembly with the 2 screws.


Hide 87151J 6.INSTALL NO. 1 DAMPER PLATE (for Automatic Air Conditioning System)

a.

Move the gear of the blower assembly so that the shape of the output shaft of the No. 1 blower damper servo sub-assembly and the shape of the center portion of the No. 1 damper plate are aligned.

I116338C01
1.865,1.198 3.25,2.188 3.25,2.188 4.875,1.698 true 3.167,2.229 3.479,2.385 0.313,0.156 10 false *a
*a Align shapes - -



b.
I116465C01
2.146,0.854 2.594,0.625 true 0.521,0.719 1.219,1.24 true 0.323,0.615 0.635,0.771 0.313,0.156 10 false *a 2.656,0.531 2.969,0.688 0.313,0.156 10 false *a
*a Link


Align the gear of the blower assembly and the engagement portion of the No. 1 damper plate, and engage the claw to install the No. 1 damper plate.


Hide 55908A 7.INSTALL AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System)

a.

for Single Layer Type:

i.

Set the cable gear and unit gear to the recirculation position.

I116340C01
1.313,1.229 1.625,1.385 0.313,0.156 10 false *a 5.635,0.729 5.823,0.906 0.188,0.177 10 true *a
*a Recirculation - -



ii.
I116455

Engage the claws to install the air inlet damper control cable sub-assembly.