REFRIGERANT (for Gasoline Model)
Refrigerant charge volume (for HFC-134a (R134a)) 300 to 400 g (10.6 to 14.1 oz)
Refrigerant charge volume (for HFO-1234yf(R1234yf)) 320 to 380 g (11.3 to 13.4 oz)

REFRIGERANT (for HV Model)
Refrigerant charge volume (for HFC-134a (R134a)) 400 to 500 g (14.1 to 17.6 oz)
Refrigerant charge volume (for HFO-1234yf(R1234yf)) 420 to 480 g (14.8 to 16.9 oz)

BLOWER RESISTOR
Tester Connection Condition Specified Condition
H30-1 (E) - H30-4 (HI) Always 3.12 to 3.60 Ω
H30-2 (M2) - H30-4 (HI) Always 0.52 to 0.60 Ω
H30-3 (M1) - H30-4 (HI) Always 1.45 to 1.67 Ω

ROOM TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
H58-1 (+) - H58-2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
H58-1 (+) - H58-2 (-) 15°C (59°F) 2.45 to 2.88 kΩ
H58-1 (+) - H58-2 (-) 20°C (68°F) 1.95 to 2.30 kΩ
H58-1 (+) - H58-2 (-) 25°C (77°F) 1.60 to 1.80 kΩ
H58-1 (+) - H58-2 (-) 30°C (86°F) 1.28 to 1.47 kΩ
H58-1 (+) - H58-2 (-) 35°C (95°F) 1.00 to 1.22 kΩ
H58-1 (+) - H58-2 (-) 40°C (104°F) 0.80 to 1.00 kΩ
H58-1 (+) - H58-2 (-) 45°C (113°F) 0.65 to 0.85 kΩ
H58-1 (+) - H58-2 (-) 50°C (122°F) 0.50 to 0.70 kΩ
H58-1 (+) - H58-2 (-) 55°C (131°F) 0.44 to 0.60 kΩ
H58-1 (+) - H58-2 (-) 60°C (140°F) 0.36 to 0.50 kΩ

AMBIENT TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
A52-1 (SO-) - A52-2 (SO+) 10°C (50°F) 3.00 to 3.73 kΩ
A52-1 (SO-) - A52-2 (SO+) 15°C (59°F) 2.45 to 2.88 kΩ
A52-1 (SO-) - A52-2 (SO+) 20°C (68°F) 1.95 to 2.30 kΩ
A52-1 (SO-) - A52-2 (SO+) 25°C (77°F) 1.60 to 1.80 kΩ
A52-1 (SO-) - A52-2 (SO+) 30°C (86°F) 1.28 to 1.47 kΩ
A52-1 (SO-) - A52-2 (SO+) 35°C (95°F) 1.00 to 1.22 kΩ
A52-1 (SO-) - A52-2 (SO+) 40°C (104°F) 0.80 to 1.00 kΩ
A52-1 (SO-) - A52-2 (SO+) 45°C (113°F) 0.65 to 0.85 kΩ
A52-1 (SO-) - A52-2 (SO+) 50°C (122°F) 0.50 to 0.70 kΩ
A52-1 (SO-) - A52-2 (SO+) 55°C (131°F) 0.44 to 0.60 kΩ
A52-1 (SO-) - A52-2 (SO+) 60°C (140°F) 0.36 to 0.50 kΩ

FRONT EVAPORATOR TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
h5-1 - h5-2 -10°C (14°F) 7.30 to 9.10 kΩ
h5-1 - h5-2 -5°C (23°F) 5.65 to 6.95 kΩ
h5-1 - h5-2 0°C (32°F) 4.40 to 5.35 kΩ
h5-1 - h5-2 5°C (41°F) 3.40 to 4.15 kΩ
h5-1 - h5-2 10°C (50°F) 2.70 to 3.25 kΩ
h5-1 - h5-2 15°C (59°F) 2.14 to 2.58 kΩ
h5-1 - h5-2 20°C (68°F) 1.71 to 2.05 kΩ
h5-1 - h5-2 25°C (77°F) 1.38 to 1.64 kΩ
h5-1 - h5-2 30°C (86°F) 1.11 to 1.32 kΩ

SOLAR SENSOR
Tester Connection Switch Condition Specified Condition
H78-2 (CLTE) - Body ground Always Below 1 Ω

AIR CONDITIONING PRESSURE SENSOR (for Automatic Air Conditioning System)
Tester Connection Condition Specified Condition
A51-1 (-) - H25-15 (SG-4) Always Below 1 Ω
A51-2 (PR) - H25-6 (PRE) Always Below 1 Ω
A51-3 (+) - H25-11 (S5-3) Always Below 1 Ω
A51-1 (-) - Body ground Always 10 kΩ or higher
H25-15 (SG-4) - Body ground Always 10 kΩ or higher
A51-2 (PR) - Body ground Always 10 kΩ or higher
H25-6 (PRE) - Body ground Always 10 kΩ or higher
A51-3 (+) - Body ground Always 10 kΩ or higher
H25-11 (S5-3) - Body ground Always 10 kΩ or higher

AIR CONDITIONING PRESSURE SENSOR (for Manual Air Conditioning System)
Tester Connection Condition Specified Condition
A51-1 (-) - H23-12 (SG-4) Always Below 1 Ω
A51-2 (PR) - H23-36 (PRE) Always Below 1 Ω
A51-3 (+) - H23-11 (S5-3) Always Below 1 Ω
A51-1 (-) - Body ground Always 10 kΩ or higher
H23-12 (SG-4) - Body ground Always 10 kΩ or higher
A51-2 (PR) - Body ground Always 10 kΩ or higher
H23-36 (PRE) - Body ground Always 10 kΩ or higher
A51-3 (+) - Body ground Always 10 kΩ or higher
H23-11 (S5-3) - Body ground Always 10 kΩ or higher

NO. 1 HEATER CONTROL SUB-ASSEMBLY (for Single Layer Type)
Tester Connection Switch Position Specified Condition
H56-2 (ERDF) - H56-9 (DRLG) Defogger sensing on position Below 1 Ω

NO. 1 HEATER CONTROL SUB-ASSEMBLY (for Double Layer Type)
Tester Connection Switch Position Specified Condition
H56-2 (ERDF) - H56-9 (DRLG) Defogger sensing on position Below 1 Ω
H56-2 (ERDF) - H56-10 (FRDL) Recirculation/Fresh bilayer sensing switch ON position (counterclockwise) Below 1 Ω
H56-2 (ERDF) - H56-10 (FRDL) Recirculation/Fresh bilayer sensing switch OFF position (clockwise) Below 1 Ω

NO. 2 HEATER CONTROL SUB-ASSEMBLY (for Single Layer Type)
Tester Connection Switch Position Specified Condition
H33-3 (LO) - H33-5 (E) Blower switch: OFF 10 kΩ or higher
H33-10 (M1) - H33-5 (E) Blower switch: OFF 10 kΩ or higher
H33-6 (M2) - H33-5 (E) Blower switch: OFF 10 kΩ or higher
H33-1 (HI) - H33-5 (E) Blower switch: OFF 10 kΩ or higher
H33-3 (LO) - H33-5 (E) Blower switch: LO Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: LO - M1 Below 1 Ω
H33-10 (M1) - H33-5 (E) Blower switch: LO - M1 Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: M1 Below 1 Ω
H33-10 (M1) - H33-5 (E) Blower switch: M1 Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: M1 - M2 Below 1 Ω
H33-10 (M1) - H33-5 (E) Blower switch: M1 - M2 Below 1 Ω
H33-6 (M2) - H33-5 (E) Blower switch: M1 - M2 Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: M2 Below 1 Ω
H33-6 (M2) - H33-5 (E) Blower switch: M2 Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: M2 - HI Below 1 Ω
H33-6 (M2) - H33-5 (E) Blower switch: M2 - HI Below 1 Ω
H33-1 (HI) - H33-5 (E) Blower switch: M2 - HI Below 1 Ω
H33-3 (LO) - H33-5 (E) Blower switch: HI Below 1 Ω
H33-1 (HI) - H33-5 (E) Blower switch: HI Below 1 Ω

NO. 2 HEATER CONTROL SUB-ASSEMBLY (for Double Layer Type)
Tester Connection Switch Position Specified Condition
H34-5 (LO) - H34-1 (E) Blower switch: OFF 10 kΩ or higher
H34-8 (MI) - H34-1 (E) Blower switch: OFF 10 kΩ or higher
H34-4 (M2) - H34-1 (E) Blower switch: OFF 10 kΩ or higher
H34-7 (HI) - H34-1 (E) Blower switch: OFF 10 kΩ or higher
H34-5 (LO) - H34-1 (E) Blower switch: LO Below 1 Ω
H34-5 (LO) - H34-1 (E) Blower switch: LO - M1 Below 1 Ω
H34-8 (MI) - H34-1 (E) Blower switch: LO - M1 Below 1 Ω
H34-5 (LO) - H34-1 (E) Blower switch: M1 Below 1 Ω
H34-8 (MI) - H34-1 (E) Blower switch: M1 Below 1 Ω
H34-5 (LO) - H34-1 (E) Blower switch: M1 - M2 Below 1 Ω
H34-8 (MI) - H34-1 (E) Blower switch: M1 - M2 Below 1 Ω
H34-4 (M2) - H34-1 (E) Blower switch: M1 - M2 Below 1 Ω
H34-5 (LO) - H34-1 (E) Blower switch: M2 Below 1 Ω
H34-4 (M2) - H34-1 (E) Blower switch: M2 Below 1 Ω
H34-5 (LO) - H34-1 (E) Blower switch: M2 - HI Below 1 Ω
H34-4 (M2) - H34-1 (E) Blower switch: M2 - HI Below 1 Ω
H34-7 (HI) - H34-1 (E) Blower switch: M2 - HI Below 1 Ω
H34-5 (LO) - H34-1 (E) Blower switch: HI Below 1 Ω
H34-7 (HI) - H34-1 (E) Blower switch: HI Below 1 Ω
H63-5 (IG+) - H63-3 (F/R) Recirculation/Fresh switch: ON Below 1 Ω
H63-5 (IG+) - H63-3 (F/R) Recirculation/Fresh switch: OFF 10 kΩ or higher

NO. 3 HEATER CONTROL SUB-ASSEMBLY (except 1KR-FE)
Tester Connection Switch Condition Specified Condition
H26-1 (IG+) - H26-2 (MAXH) Except MAX HOT 10 kΩ or higher
H26-1 (IG+) - H26-2 (MAXH) MAX HOT Below 1 Ω
H26-1 (IG+) - H26-7 (MAXC) Except MAX COLD 10 kΩ or higher
H26-1 (IG+) - H26-7 (MAXC) MAX COLD Below 1 Ω
H26-1 (IG+) - H26-8 (A/C) A/C switch ON position Below 1 Ω
H26-1 (IG+) - H26-8 (A/C) A/C switch OFF position 10 kΩ or higher

NO. 3 HEATER CONTROL SUB-ASSEMBLY (for 1KR-FE)
Tester Connection Switch Condition Specified Condition
H26-1 (IG+) - H26-2 (MAXH) Except MAX HOT 10 kΩ or higher
H26-1 (IG+) - H26-2 (MAXH) MAX HOT Below 1 Ω
H26-1 (IG+) - H26-8 (A/C) A/C switch ON position Below 1 Ω
H26-1 (IG+) - H26-8 (A/C) A/C switch OFF position 10 kΩ or higher