SPECIFICATIONS
_0424515
HEATING / AIR CONDITIONING
F
SPECIFICATIONS HEATING / AIR CONDITIONING SERVICE DATA
REFRIGERANT (for Gasoline Model)
| Refrigerant charge volume (for HFC-134a (R134a))
|
300 to 400 g (10.6 to 14.1 oz)
|
| Refrigerant charge volume (for HFO-1234yf(R1234yf))
|
320 to 380 g (11.3 to 13.4 oz)
|
REFRIGERANT (for HV Model)
| Refrigerant charge volume (for HFC-134a (R134a))
|
400 to 500 g (14.1 to 17.6 oz)
|
| Refrigerant charge volume (for HFO-1234yf(R1234yf))
|
420 to 480 g (14.8 to 16.9 oz)
|
BLOWER RESISTOR
| Tester Connection
|
Condition
|
Specified Condition
|
| H30-1 (E) - H30-4 (HI)
|
Always
|
3.12 to 3.60 Ω
|
| H30-2 (M2) - H30-4 (HI)
|
Always
|
0.52 to 0.60 Ω
|
| H30-3 (M1) - H30-4 (HI)
|
Always
|
1.45 to 1.67 Ω
|
ROOM TEMPERATURE SENSOR
| Tester Connection
|
Condition
|
Specified Condition
|
| H58-1 (+) - H58-2 (-)
|
10°C (50°F)
|
3.00 to 3.73 kΩ
|
| H58-1 (+) - H58-2 (-)
|
15°C (59°F)
|
2.45 to 2.88 kΩ
|
| H58-1 (+) - H58-2 (-)
|
20°C (68°F)
|
1.95 to 2.30 kΩ
|
| H58-1 (+) - H58-2 (-)
|
25°C (77°F)
|
1.60 to 1.80 kΩ
|
| H58-1 (+) - H58-2 (-)
|
30°C (86°F)
|
1.28 to 1.47 kΩ
|
| H58-1 (+) - H58-2 (-)
|
35°C (95°F)
|
1.00 to 1.22 kΩ
|
| H58-1 (+) - H58-2 (-)
|
40°C (104°F)
|
0.80 to 1.00 kΩ
|
| H58-1 (+) - H58-2 (-)
|
45°C (113°F)
|
0.65 to 0.85 kΩ
|
| H58-1 (+) - H58-2 (-)
|
50°C (122°F)
|
0.50 to 0.70 kΩ
|
| H58-1 (+) - H58-2 (-)
|
55°C (131°F)
|
0.44 to 0.60 kΩ
|
| H58-1 (+) - H58-2 (-)
|
60°C (140°F)
|
0.36 to 0.50 kΩ
|
AMBIENT TEMPERATURE SENSOR
| Tester Connection
|
Condition
|
Specified Condition
|
| A52-1 (SO-) - A52-2 (SO+)
|
10°C (50°F)
|
3.00 to 3.73 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
15°C (59°F)
|
2.45 to 2.88 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
20°C (68°F)
|
1.95 to 2.30 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
25°C (77°F)
|
1.60 to 1.80 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
30°C (86°F)
|
1.28 to 1.47 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
35°C (95°F)
|
1.00 to 1.22 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
40°C (104°F)
|
0.80 to 1.00 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
45°C (113°F)
|
0.65 to 0.85 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
50°C (122°F)
|
0.50 to 0.70 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
55°C (131°F)
|
0.44 to 0.60 kΩ
|
| A52-1 (SO-) - A52-2 (SO+)
|
60°C (140°F)
|
0.36 to 0.50 kΩ
|
FRONT EVAPORATOR TEMPERATURE SENSOR
| Tester Connection
|
Condition
|
Specified Condition
|
| h5-1 - h5-2
|
-10°C (14°F)
|
7.30 to 9.10 kΩ
|
| h5-1 - h5-2
|
-5°C (23°F)
|
5.65 to 6.95 kΩ
|
| h5-1 - h5-2
|
0°C (32°F)
|
4.40 to 5.35 kΩ
|
| h5-1 - h5-2
|
5°C (41°F)
|
3.40 to 4.15 kΩ
|
| h5-1 - h5-2
|
10°C (50°F)
|
2.70 to 3.25 kΩ
|
| h5-1 - h5-2
|
15°C (59°F)
|
2.14 to 2.58 kΩ
|
| h5-1 - h5-2
|
20°C (68°F)
|
1.71 to 2.05 kΩ
|
| h5-1 - h5-2
|
25°C (77°F)
|
1.38 to 1.64 kΩ
|
| h5-1 - h5-2
|
30°C (86°F)
|
1.11 to 1.32 kΩ
|
SOLAR SENSOR
| Tester Connection
|
Switch Condition
|
Specified Condition
|
| H78-2 (CLTE) - Body ground
|
Always
|
Below 1 Ω
|
AIR CONDITIONING PRESSURE SENSOR (for Automatic Air Conditioning System)
| Tester Connection
|
Condition
|
Specified Condition
|
| A51-1 (-) - H25-15 (SG-4)
|
Always
|
Below 1 Ω
|
| A51-2 (PR) - H25-6 (PRE)
|
Always
|
Below 1 Ω
|
| A51-3 (+) - H25-11 (S5-3)
|
Always
|
Below 1 Ω
|
| A51-1 (-) - Body ground
|
Always
|
10 kΩ or higher
|
| H25-15 (SG-4) - Body ground
|
Always
|
10 kΩ or higher
|
| A51-2 (PR) - Body ground
|
Always
|
10 kΩ or higher
|
| H25-6 (PRE) - Body ground
|
Always
|
10 kΩ or higher
|
| A51-3 (+) - Body ground
|
Always
|
10 kΩ or higher
|
| H25-11 (S5-3) - Body ground
|
Always
|
10 kΩ or higher
|
AIR CONDITIONING PRESSURE SENSOR (for Manual Air Conditioning System)
| Tester Connection
|
Condition
|
Specified Condition
|
| A51-1 (-) - H23-12 (SG-4)
|
Always
|
Below 1 Ω
|
| A51-2 (PR) - H23-36 (PRE)
|
Always
|
Below 1 Ω
|
| A51-3 (+) - H23-11 (S5-3)
|
Always
|
Below 1 Ω
|
| A51-1 (-) - Body ground
|
Always
|
10 kΩ or higher
|
| H23-12 (SG-4) - Body ground
|
Always
|
10 kΩ or higher
|
| A51-2 (PR) - Body ground
|
Always
|
10 kΩ or higher
|
| H23-36 (PRE) - Body ground
|
Always
|
10 kΩ or higher
|
| A51-3 (+) - Body ground
|
Always
|
10 kΩ or higher
|
| H23-11 (S5-3) - Body ground
|
Always
|
10 kΩ or higher
|
NO. 1 HEATER CONTROL SUB-ASSEMBLY (for Single Layer Type)
| Tester Connection
|
Switch Position
|
Specified Condition
|
| H56-2 (ERDF) - H56-9 (DRLG)
|
Defogger sensing on position
|
Below 1 Ω
|
NO. 1 HEATER CONTROL SUB-ASSEMBLY (for Double Layer Type)
| Tester Connection
|
Switch Position
|
Specified Condition
|
| H56-2 (ERDF) - H56-9 (DRLG)
|
Defogger sensing on position
|
Below 1 Ω
|
| H56-2 (ERDF) - H56-10 (FRDL)
|
Recirculation/Fresh bilayer sensing switch ON position (counterclockwise)
|
Below 1 Ω
|
| H56-2 (ERDF) - H56-10 (FRDL)
|
Recirculation/Fresh bilayer sensing switch OFF position (clockwise)
|
Below 1 Ω
|
NO. 2 HEATER CONTROL SUB-ASSEMBLY (for Single Layer Type)
| Tester Connection
|
Switch Position
|
Specified Condition
|
| H33-3 (LO) - H33-5 (E)
|
Blower switch: OFF
|
10 kΩ or higher
|
| H33-10 (M1) - H33-5 (E)
|
Blower switch: OFF
|
10 kΩ or higher
|
| H33-6 (M2) - H33-5 (E)
|
Blower switch: OFF
|
10 kΩ or higher
|
| H33-1 (HI) - H33-5 (E)
|
Blower switch: OFF
|
10 kΩ or higher
|
| H33-3 (LO) - H33-5 (E)
|
Blower switch: LO
|
Below 1 Ω
|
| H33-3 (LO) - H33-5 (E)
|
Blower switch: LO - M1
|
Below 1 Ω
|
| H33-10 (M1) - H33-5 (E)
|
Blower switch: LO - M1
|
Below 1 Ω
|
| H33-3 (LO) - H33-5 (E)
|
Blower switch: M1
|
Below 1 Ω
|
| H33-10 (M1) - H33-5 (E)
|
Blower switch: M1
|
Below 1 Ω
|
| H33-3 (LO) - H33-5 (E)
|
Blower switch: M1 - M2
|
Below 1 Ω
|
| H33-10 (M1) - H33-5 (E)
|
Blower switch: M1 - M2
|
Below 1 Ω
|
| H33-6 (M2) - H33-5 (E)
|
Blower switch: M1 - M2
|
Below 1 Ω
|
| H33-3 (LO) - H33-5 (E)
|
Blower switch: M2
|
Below 1 Ω
|
| H33-6 (M2) - H33-5 (E)
|
Blower switch: M2
|
Below 1 Ω
|
| H33-3 (LO) - H33-5 (E)
|
Blower switch: M2 - HI
|
Below 1 Ω
|
| H33-6 (M2) - H33-5 (E)
|
Blower switch: M2 - HI
|
Below 1 Ω
|
| H33-1 (HI) - H33-5 (E)
|
Blower switch: M2 - HI
|
Below 1 Ω
|
| H33-3 (LO) - H33-5 (E)
|
Blower switch: HI
|
Below 1 Ω
|
| H33-1 (HI) - H33-5 (E)
|
Blower switch: HI
|
Below 1 Ω
|
NO. 2 HEATER CONTROL SUB-ASSEMBLY (for Double Layer Type)
| Tester Connection
|
Switch Position
|
Specified Condition
|
| H34-5 (LO) - H34-1 (E)
|
Blower switch: OFF
|
10 kΩ or higher
|
| H34-8 (MI) - H34-1 (E)
|
Blower switch: OFF
|
10 kΩ or higher
|
| H34-4 (M2) - H34-1 (E)
|
Blower switch: OFF
|
10 kΩ or higher
|
| H34-7 (HI) - H34-1 (E)
|
Blower switch: OFF
|
10 kΩ or higher
|
| H34-5 (LO) - H34-1 (E)
|
Blower switch: LO
|
Below 1 Ω
|
| H34-5 (LO) - H34-1 (E)
|
Blower switch: LO - M1
|
Below 1 Ω
|
| H34-8 (MI) - H34-1 (E)
|
Blower switch: LO - M1
|
Below 1 Ω
|
| H34-5 (LO) - H34-1 (E)
|
Blower switch: M1
|
Below 1 Ω
|
| H34-8 (MI) - H34-1 (E)
|
Blower switch: M1
|
Below 1 Ω
|
| H34-5 (LO) - H34-1 (E)
|
Blower switch: M1 - M2
|
Below 1 Ω
|
| H34-8 (MI) - H34-1 (E)
|
Blower switch: M1 - M2
|
Below 1 Ω
|
| H34-4 (M2) - H34-1 (E)
|
Blower switch: M1 - M2
|
Below 1 Ω
|
| H34-5 (LO) - H34-1 (E)
|
Blower switch: M2
|
Below 1 Ω
|
| H34-4 (M2) - H34-1 (E)
|
Blower switch: M2
|
Below 1 Ω
|
| H34-5 (LO) - H34-1 (E)
|
Blower switch: M2 - HI
|
Below 1 Ω
|
| H34-4 (M2) - H34-1 (E)
|
Blower switch: M2 - HI
|
Below 1 Ω
|
| H34-7 (HI) - H34-1 (E)
|
Blower switch: M2 - HI
|
Below 1 Ω
|
| H34-5 (LO) - H34-1 (E)
|
Blower switch: HI
|
Below 1 Ω
|
| H34-7 (HI) - H34-1 (E)
|
Blower switch: HI
|
Below 1 Ω
|
| H63-5 (IG+) - H63-3 (F/R)
|
Recirculation/Fresh switch: ON
|
Below 1 Ω
|
| H63-5 (IG+) - H63-3 (F/R)
|
Recirculation/Fresh switch: OFF
|
10 kΩ or higher
|
NO. 3 HEATER CONTROL SUB-ASSEMBLY (except 1KR-FE)
| Tester Connection
|
Switch Condition
|
Specified Condition
|
| H26-1 (IG+) - H26-2 (MAXH)
|
Except MAX HOT
|
10 kΩ or higher
|
| H26-1 (IG+) - H26-2 (MAXH)
|
MAX HOT
|
Below 1 Ω
|
| H26-1 (IG+) - H26-7 (MAXC)
|
Except MAX COLD
|
10 kΩ or higher
|
| H26-1 (IG+) - H26-7 (MAXC)
|
MAX COLD
|
Below 1 Ω
|
| H26-1 (IG+) - H26-8 (A/C)
|
A/C switch ON position
|
Below 1 Ω
|
| H26-1 (IG+) - H26-8 (A/C)
|
A/C switch OFF position
|
10 kΩ or higher
|
NO. 3 HEATER CONTROL SUB-ASSEMBLY (for 1KR-FE)
| Tester Connection
|
Switch Condition
|
Specified Condition
|
| H26-1 (IG+) - H26-2 (MAXH)
|
Except MAX HOT
|
10 kΩ or higher
|
| H26-1 (IG+) - H26-2 (MAXH)
|
MAX HOT
|
Below 1 Ω
|
| H26-1 (IG+) - H26-8 (A/C)
|
A/C switch ON position
|
Below 1 Ω
|
| H26-1 (IG+) - H26-8 (A/C)
|
A/C switch OFF position
|
10 kΩ or higher
|