Home › Engine / Hybrid System › G16E-GTS (EMISSION CONTROL) › PURGE VALVE › from 2020.09
RM36W0E _51 Engine / Hybrid System _095691 G16E-GTS EMISSION CONTROL _0449381 PURGE VALVE G

G16E-GTS EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 25860 1.INSPECT PURGE VALVE (PURGE VSV)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D96-1 - D96-2 20°C (68°F) 23 to 26 Ω


If the result is not as specified, replace the purge valve (purge VSV).


b.
A461438C01
2.073,0.313 2.458,0.531 0.385,0.219 1.531,1.875 1.531,1.365 true 0.781,1.208 0.656,0.76 0.656,0.76 0.531,0.76 false 1.458,1.854 1.76,2.177 0.302,0.323 10 false *a 0.354,0.688 0.594,0.969 0.24,0.281 10 false *b 2.177,1.635 2.469,1.906 0.292,0.271 10 false *c 2.292,0.021 2.51,0.26 0.219,0.24 10 false *d 2.167,0.354 2.625,0.552 0.458,0.198 10 false D96
*a Port (E)
*b Port (F)
*c Air
*d Component without harness connected
(Purge Valve (Purge VSV))


Apply auxiliary battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).

OK:
Condition Specified Condition
Auxiliary battery voltage applied between terminals 1 and 2 Air flows from port (F)
Auxiliary battery voltage not applied between terminals 1 and 2 Air does not flow


If the result is not as specified, replace the purge valve (purge VSV).