Home › Engine / Hybrid System › G16E-GTS (EMISSION CONTROL) › CANISTER › from 2020.09
RM36W0E _51 Engine / Hybrid System _095691 G16E-GTS EMISSION CONTROL _0449384 CANISTER G

G16E-GTS EMISSION CONTROL  CANISTER  INSPECTION  


PROCEDURE

Hide 1.CHECK CANISTER (FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY)

a.

Visually check the canister (fuel suction with pump and gauge tube assembly).

i.

Visually check the canister (fuel suction with pump and gauge tube assembly) for cracks or damage.

If cracks or damage are found, replace the canister (fuel suction with pump and gauge tube assembly).



b.

Inspect the airflow of the canister (fuel suction with pump and gauge tube assembly).

i.
A379119C02
0.594,1.938 0.781,1.938 0.781,1.938 1.823,1.208 true 1.073,0.313 1.229,0.313 1.229,0.313 1.365,0.688 false 2.448,0.229 2.354,0.229 2.354,0.229 2,0.969 false 0.406,1.833 0.625,2.031 0.219,0.198 10 false *c 0.833,0.24 1.146,0.396 0.313,0.156 10 false *a 2.5,0.125 2.771,0.292 0.271,0.167 10 true *b 2.531,1.792 2.76,2 0.229,0.208 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Air


Close the port (B) and check that air flows from the port (A) when air is blown into the port (C).

OK:

Air flows from the port (A).




c.

Inspect the check valve.

i.
A324771C02
1.427,0.198 1.604,0.198 1.604,0.198 1.708,0.479 false 2.396,0.792 2.635,0.583 2.635,0.583 2.792,0.583 false 2.188,1.042 1.865,2.021 1.865,2.021 1.708,2.021 true 1.51,1.938 1.719,2.125 0.208,0.188 10 true *c 1.219,0.125 1.531,0.281 0.313,0.156 10 false *a 2.865,0.49 3.208,0.823 0.344,0.333 10 false *b 2.531,0.156 2.844,0.354 0.313,0.198 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Air


Close the port (C) and check that air flows from the port (B) when air is blown into the port (A).

OK:

Air flows from the port (B).



ii.
A310377C02
1.531,0.25 1.948,0.25 false 1.656,1.781 1.479,1.479 1.479,1.479 1.333,1.479 false 2.313,2.313 2.917,2.313 true 2.458,2.094 2.823,1.49 2.823,1.49 3.021,1.49 true 1.115,1.396 1.427,1.635 0.313,0.24 10 false *a 3.073,1.427 3.385,1.677 0.313,0.25 10 false *b 3,2.24 3.219,2.49 0.219,0.25 10 false *c 2.01,0.156 2.229,0.406 0.219,0.25 10 false *d
*a Port (A)
*b Port (B)
*c Port (C)
*d Vacuum Pump


Using a vacuum pump, apply vacuum to the port (A) with the port (C) closed and check that air flows into the port (B).

OK:

The vacuum is maintained at first. By gradually increasing the vacuum, air flows and the vacuum decreases after the vacuum reaches a certain level.