88718L
1.INSTALL PIPING CLAMP (except 1KR-FE)
Remove the vinyl tape from the open ends of the suction pipe sub-assembly and suction hose sub-assembly.
| *1 | Suction Hose Sub-assembly |
| *2 | Piping Clamp |
| *a | Groove |
Install a new piping clamp to the suction hose sub-assembly.
Securely engage the inside step of the piping clamp in the suction hose sub-assembly groove.
Do not widen the opening of the piping clamp more than the diameter of the suction hose sub-assembly when installing it.
Do not install the piping clamp with the large diameter section in the wrong direction.
Thoroughly coat 2 new O-rings and contact surface of the suction hose sub-assembly with compressor oil.
for Gasoline Model (for HFC-134a(R134a)):
ND-OIL 8 or equivalent
for Gasoline Model (for HFO-1234yf(R1234yf)):
ND-OIL 12 or equivalent
for HV Model:
ND-OIL 11 or equivalent
Install the 2 O-rings to the suction hose sub-assembly.
Do not let foreign matter adhere to the O-rings or O-ring seals.
| *a | Large Diameter Section of Piping Clamp |
| *b | Alignment Mark |
Engage the suction pipe sub-assembly and suction hose sub-assembly by matching the alignment marks.
Engage the parts by holding the pipe, not the piping clamp.
| *a | Large Diameter Section of Piping Clamp |
Securely insert the piping clamp to the point where the large diameter section of the piping clamp is covered by the suction pipe sub-assembly.
When inserting, make sure that a click sound is heard.
Check that the suction hose sub-assembly is securely inserted by pulling it.
88718L
2.INSTALL PIPING CLAMP (for 1KR-FE)
Remove the vinyl tape from the open ends of the air conditioner tube and accessory assembly and suction hose sub-assembly.
| *1 | Suction Hose Sub-assembly |
| *2 | Piping Clamp |
| *a | Groove |
Install a new piping clamp to the suction hose sub-assembly.
Securely engage the inside step of the piping clamp in the suction hose sub-assembly groove.
Do not widen the opening of the piping clamp more than the diameter of the suction hose sub-assembly when installing it.
Do not install the piping clamp with the large diameter section in the wrong direction.
Thoroughly coat 2 new O-rings and contact surface of the suction hose sub-assembly with compressor oil.
ND-OIL 8 or equivalent
ND-OIL 12 or equivalent
Install the 2 O-rings to the suction hose sub-assembly.
Do not let foreign matter adhere to the O-rings or O-ring seals.
| *a | Large Diameter Section of Piping Clamp |
| *b | Alignment Mark |
Engage the air conditioner tube and accessory assembly and suction hose sub-assembly by matching the alignment marks.
Engage the parts by holding the pipe, not the piping clamp.
| *a | Large Diameter Section of Piping Clamp |
Securely insert the piping clamp to the point where the large diameter section of the piping clamp is covered by the air conditioner tube and accessory assembly.
When inserting, make sure that a click sound is heard.
Check that the suction hose sub-assembly is securely inserted by pulling it.