Home › Drivetrain › EA67F (MANUAL TRANSMISSION / TRANSAXLE) › SPEED SENSOR › from 2020.09
RM36W0E _52 Drivetrain _095283 EA67F MANUAL TRANSMISSION / TRANSAXLE _0449595 SPEED SENSOR G

EA67F MANUAL TRANSMISSION / TRANSAXLE  SPEED SENSOR  INSPECTION  


CAUTION / NOTICE / HINT

PROCEDURE

Hide 89413B 1.INSPECT TRANSMISSION REVOLUTION SENSOR

a.

Connect the battery to the sensor as shown in the illustration.

C154686C93
4.802,0.417 6.844,2.365 2.042,1.948 5.615,0.51 6.021,0.719 0.406,0.208 3.438,0.458 3.729,0.302 false 2.031,0.698 2.323,0.542 false 5.396,2 5.646,1.583 true 6.25,2 6,1.583 true 0.719,2.073 0.719,1.854 false 0.656,0.302 0.896,0.469 0.24,0.167 10 false *b 1.927,0.635 2.031,0.771 0.104,0.135 10 false 2 3.781,0.219 3.875,0.365 0.094,0.146 10 false 1 0.656,2.125 0.844,2.292 0.188,0.167 10 false *1 2.625,2.094 2.844,2.302 0.219,0.208 10 false *d 3.531,1.833 3.719,2.042 0.188,0.208 10 false *c 4.896,0.51 5.083,0.719 0.188,0.208 10 false *a 5.188,2.031 5.802,2.229 0.615,0.198 10 false NIMB 6.104,2.031 6.719,2.229 0.615,0.198 10 false NIMO 5.698,0.542 6.156,0.74 0.458,0.198 10 false D64
*1 Auxiliary Battery - -
*a Component without harness connected
(Transmission Revolution Sensor)
*b Ammeter
*c Magnet *d 5 mm or less



b.

Wave a magnetic object left and right in front of the transmission revolution sensor tip (5 mm (0.197 in.) or less) to change the high/low signals while measuring the current.

NOTICE:

Make sure to wave the magnetic object during the inspection. The current will not change without waving the magnetic object as indicated by the arrow in the illustration.



c.

Measure the current according to the value(s) in the table below.

Standard Current:
Tester Connection Condition Specified Condition
D64-1(NIMO) - D64-2(NIMB) Low signal 4 to 8 mA
D64-1(NIMO) - D64-2(NIMB) High signal 12 to 16 mA