33311
1.INSPECT INPUT SHAFT
Check the input shaft for wear and damage.
Using a dial indicator, measure the input shaft runout.
0.01 mm (0.000394 in.)
If the runout exceeds the maximum, replace the input shaft.
Using a micrometer, measure the outer diameter of the input shaft journal surface.
| Measured Part | Outer Diameter mm (in.) |
|---|---|
| A | 30.008 to 30.020 (1.181 to 1.182) |
| B | 32.002 to 32.018 (1.260 to 1.261) |
If the outer diameter is below the minimum, replace the input shaft.