89615
1.INSPECT KNOCK SENSOR
| *a | Component without harness connected
(Knock Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| e1-1 - e1-2 | 25°C (77°F) | 120 to 280 kΩ |
If the result is not as specified, replace the knock sensor.