Home › General › SPECIFICATIONS › G16E-GTS COOLING › from 2020.09
RM36W0E _V1 General _087262 SPECIFICATIONS _0449899 G16E-GTS COOLING F

SPECIFICATIONS  G16E-GTS COOLING  TORQUE SPECIFICATIONS  


Water pump
Part Tightened N*m kgf*cm ft.*lbf in.*lbf
Water inlet with water pump housing sub-assembly x Cylinder block sub-assembly 43 438 32
Air connector stay x Water inlet with water pump housing sub-assembly 43 438 381
Water pump pulley x Water inlet with water pump housing sub-assembly 21 214 15

Thermostat
Part Tightened N*m kgf*cm ft.*lbf
Water inlet with thermostat sub-assembly x Water inlet with water pump housing sub-assembly 10 102 7

Cooling fan motor
Part Tightened N*m kgf*cm in.*lbf
Cooling fan motor x Fan shroud 3.9 40 35
Fan x Cooling fan motor 3.9 40 35

Radiator
Part Tightened N*m kgf*cm ft.*lbf in.*lbf
Upper front radiator support x Front side member bracket sub-assembly 7.1 72 63