INSTALLATION
Removal / installation · Vehicles built from Nov 2006
| 1. ADJUST COMPRESSOR OIL |
![]() ![]() |
When replacing the compressor with a new one, gradually discharge the refrigerant gas from the service valve. Then drain the following amount of oil from the new compressor before installation, so that the amount of oil contained in it is the same as that in the compressor to be replaced.
- HINT:
- New compressors are filled with sufficient oil for the whole cycle. Therefore, it is necessary to drain residual oil from the condenser and cooling unit.
- Standard:
- (The amount of oil inside a new compressor: 60 (+15) cc (2.0 (+0.51) fl.oz.)) - (The amount of oil remaining in the removed compressor) = The amount of oil to be removed when replacing the compressor
- NOTICE:
- When checking the compressor oil level, observe the precautions for cooler removal/installation.
- If a new compressor is installed without removing the amount of oil remaining in the pipes of the vehicle, the amount of oil becomes too large. This prevents heat exchange in the refrigerant cycle and causes refrigeration failure.
- If the amount of oil remaining in the removed compressor is too low, check for oil leakage.
- Use ND-OIL8 compressor oil.
- When checking the compressor oil level, observe the precautions for cooler removal/installation.
| 2. INSTALL COMPRESSOR AND PULLEY |
![]() ![]() |
Using "TORX" socket wrench E8, install the compressor with the 2 stud bolts.
- Torque:
- 15 N*m{ 153 kgf*cm , 11 ft.*lbf }
Tighten the compressor with the 2 bolts and 2 nuts.

- Torque:
- 25 N*m{ 250 kgf*cm , 18 ft.*lbf }
- NOTICE:
- Tighten the bolts in the following order: 1 (provisional tightening) → 2 → 3 → 4 → 1.
Connect the connector and the clamp.
| 3. INSTALL NO. 1 COOLER REFRIGERANT SUCTION HOSE |
![]() ![]() |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL8) to a new O-ring and the fitting surface of the compressor.
- Compressor oil:
- ND-OIL8 or equivalent
Install the O-ring onto the suction hose.
Install the suction hose onto the compressor with the bolt.
- Torque:
- 9.8 N*m{ 100 kgf*cm , 87 in.*lbf }
| 4. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() ![]() |
Remove the attached vinyl tape from the hose.
Apply sufficient compressor oil (ND-OIL8) to a new O-ring and the fitting surface of the compressor.
- Compressor oil:
- ND-OIL8 or equivalent
Install the O-ring onto the discharge hose.
Install the discharge hose onto the compressor with the bolt.
- Torque:
- 9.8 N*m{ 100 kgf*cm , 87 in.*lbf }
| 5. INSTALL FAN AND GENERATOR V BELT |
Provisionally install the fan and generator V belt onto each pulley.
- NOTICE:
- Make sure that the V belt is securely fitted into the rib groove of the pulley.
| 6. ADJUST FAN AND GENERATOR V BELT |
Turn adjusting bolt C and adjust the tension of the V belt.

- NOTICE:
- Check that bolt D is tightened to the specified torque of 19 N*m (189 kgf*cm, 14 ft.*lbf).
Tighten fixing bolts A and B.
- Torque:
- 19 N*m{ 189 kgf*cm , 14 ft.*lbf } for bolt A
- 43 N*m{ 438 kgf*cm , 32 ft.*lbf } for bolt B
| 7. INSPECT FAN AND GENERATOR V BELT |
Check the V belt deflection and tension.

- Deflection:
Item
Specified Condition
New belt
7.5 to 8.6 mm (0.296 to 0.338 in.)
Used belt
8.0 to 10.0 mm (0.315 to 0.397 in.)
- Tension:
Item
Specified Condition
New belt
688 to 884 N (70 to 90 kg, 155 to 199 ld)
Used belt
402 to 598 N (40 to 61 kg, 90 to 134 ld)
- HINT:
- Check the V belt deflection at the specified point.
- When installing a new belt, set its tension to the specified value.
- When inspecting a belt which has been used for over 5 minutes, apply the Used Belt specifications.
- When reinstalling a belt which has been used for over 5 minutes, adjust its deflection and tension to the intermediate values of the Used Belt specifications.
- V belt tension and deflection should be checked after 2 revolutions of engine cranking.
- When checking the tension, use a sonic tension meter.
- Check the V belt deflection at the specified point.
- Weight:
- 15 g/rib*m
- Width:
- 6 ribs (21.36 mm)
- Span:
- 188 mm (w/ A/C)
- 282 mm (w/o A/C)
| 8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
- Torque:
- 5.4 N*m{ 55 kgf*cm , 48 in.*lbf }
| 9. CHARGE REFRIGERANT |
- SST
- 07110-58060
(07117-58060, 07117-58070, 07117-58080, 07117-58090, 09985-02100, 09985-02120, 07117-78050, 07117-88060, 07117-88070, 07117-88080)


- NOTICE:
- Charge refrigerant in accordance with the equipment manual.
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).
- Standard:
- 330 to 390 g (11.64 to 13.76 oz.) w/o Fan Shroud Ventilation Duct
- 350 to 410 g (12.35 to 14.46 oz.) w/ Fan Shroud Ventilation Duct
- NOTICE:
- Do not start the engine before charging it with refrigerant as the cooler compressor doesn't work properly without sufficient refrigerant. This could cause the compressor to overheat.
- HINT:
- The relationship between the refrigerant charge amount and the pressure is as follows.


- High Charge Range:
If the refrigerant is overcharged, the pressure rises on the high-pressure side. High-pressure cut off frequently occurs. This causes insufficient cooling performance and also insufficient compressor lubrication.
- Low Charge Range:
Shortage of refrigerant causes insufficient cooling performance and low circulation of refrigerant oil, which shortens the compressor life. Operation with insufficient coolant raises the refrigerant temperature and causes heat deterioration of the rubber seals and hoses. Cracking and thus refrigerant leakage may occur.
- The relationship between the refrigerant charge amount and the pressure is as follows.
Install the caps onto the service valves on the refrigerant line.
| 10. WARM UP ENGINE |
- NOTICE:
- Warm up the engine at less than 2000 rpm for 1 minute or more after charging it with refrigerant.
| 11. INSPECT FOR REFRIGERANT LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation as follows:
- Stop the engine.
- Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).
- Repeat the test 2 or 3 times.
- Make sure that some refrigerant remains in the refrigeration system.
When the compressor is off: approximately 392 to 588 kPa (4 to 6 kgf*cm2, 57 to 85 psi)
- HINT:
- It is impossible for the above pressure to be maintained if there is leakage.
- Stop the engine.
Using the halogen leak detector, check the refrigerant line, especially at the connection points, for leakage.

Bring the halogen leak detector close to the drain hose before performing the test.

- HINT:
- After the blower motor has stopped, leave the cooling unit for at least 15 minutes.
- Place the halogen leak detector sensor under the drain hose.
- When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to the volatile gases.
- After the blower motor has stopped, leave the cooling unit for at least 15 minutes.
If no gas leakage is detected from the drain hose, remove the blower motor from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.
| 12. INSTALL ENGINE UNDER COVER RH |
| 13. INSTALL NO. 2 CYLINDER HEAD COVER |
Disengage the 4 fittings shown and install the No. 2 cylinder head cover by applying pressure to it.

- HINT: